On the agenda: St Joseph meeting — Data Center (Jul 13)
Past ⚠ Agenda Watch St Joseph, Minnesota · Monday, July 13, 2026 — 2 months ago
About this record
The published agenda for this July 13 meeting contains: "Data Center". The meeting has passed; the record and its outcome live here permanently.
Check the agenda document for the meeting time.
The agenda, word for word
Government public record — the full text of the published document, archived August 16, 2026. Gold highlighting of key terms is ours, not the original’s. Read the original document ↗
city of st. joseph
www.cityofstjoseph.com
St. Joseph Planning Commission
Monday, July 13th, 2026
6:00 PM
St. Joseph Council Chambers
75 Callaway St E
**The meeting will also be available through Zoom**
1. Call to Order
2. Pledge of Allegiance
3. Agenda Review and Adoption
4. Public Comment
5. Minutes – June 8th, 2026
6. New Business - none
7. Old Business
a. Summit Commons C.U.P. extension
b. Update on Moratorium’s
8. Other Business
a. General Updates
9. Adjourn
ZOOM INFORMATION
Join Zoom Meeting
https://us06web.zoom.us/j/87642407431?pwd=bXlkL3NlM2VKNXVMdmk2MC91blYxUT09
Meeting ID: 876 4240 7431
Passcode: 797162
One tap mobile
+19292056099,,87642407431#,,,,*797162# US (New York)
Dial by your location
Find your local number: https://us06web.zoom.us/u/kblhxKat7W
1
Pursuant to due call and notice thereof, the Planning Commission for the City of St. Joseph met on
Monday, June 8th, 2026, at 6:00 PM in the St. Joseph City Hall opening with the Pledge of Allegiance.
Planning Commission Members Present: Commissioners Andrew Mooney, Cody Evander, Carmie Mick,
Jon Hazen, Mark Thompson
Staff Present: Nate Keller, Grant Hellermann
Public Comments: None
Agenda Review & Adoption: Thompson made a motion to approve Agenda Review & Adoption. The
motion was seconded by Mooney and passed unanimously.
Public Comment: None
Minutes – March 9th, 2026
Thompson made a motion to approve the minutes of May 11th, 2026. The motion was seconded by
Mooney and passed unanimously.
Appointment of Vice Chair: Mooney made a motion to nominate Thompson as Vice Chair. The
motion was seconded by Hazen and passed unanimously.
Appointment of Joint Planning Board Representative: Thompson made a motion to nominate Hern as
Joint Planning Board Representative. The motion was seconded by Hazen and passed
unanimously.
New Business
7a. Home Occupation License Amendment – Cherrico Pottery
Keller explained that the owners of Cherrico Pottery requested to amend their Special Home Occupation
license for their pottery business at 29055 County Road 121. The amendment to the original resolution
approved in 2025 came forward due to a requested change to the limit of four maximum on-site and inperson retail sales events in a calendar year to twelve on-site and in-person retail sales.
Commission discussion focused on event attendance, parking availability, and how prior events impacted
neighbors.
Property owner Joel Cherrico addressed questions, providing information on the success of past events
and information regarding attendance and parking for the events.
Hazen opened the public hearing at 6:07PM
Hazen closed the public hearing at 6:07PM
Hazen made a motion to approve PC Resolution 2026-007. The motion was seconded by Mooney
and passed unanimously.
7b Country Manor Senior Living Campus PUD Amendment & Variance for Street Yard Setback
Keller explained that Country Manor was seeking approval of an amendment to the initial PUD which was
approved for 168 total units and was proposed to be decreased to 124 total units. He also explained that
a portion of the new planned building’s setback would be less than the minimum 30-foot requirement.
Approval of a variance to allow this setback. Since there is a change in the number of total units, a
change in design, and a variance to the street yard setback, the proposal was brought to the PC.
Commission discussion focused on future implications of the setback variance, construction dates, and
whether those involved in creating and revising the plan were aware of the 30-foot setback requirement.
2
CEO of Country Manor Campus Anthony Fenstad addressed questions, answering questions from the
Commission.
Hazen opened the public hearing at 6:22PM
Hazen closed the public hearing at 6:23PM
Mooney made a motion to approve PC 2026-008. The motion was seconded by Mick and passed
unanimously.
7c La Playette – Outdoor Dining Patio Proposed Structure
Keller explained La Playette has been operating a seasonal outdoor patio blocking off parking spaces in
the rear of their property with approval by the PC and Council in 2024. At the time of approval, the owners
indicated that they intended to pursue a permanent structure. Approval of such a structure, since it would
impact parking spaces, requires PC and Council approval. The applicant is seeking approval of the
proposed structure and waiver of required parking spaces.
Owner Shawn Riesner addressed questions on the proposed structure, explaining the structure has the
option to be enclosed, and concerns about impacts on parking spaces.
Mooney made a motion to approve the proposed structure and waive the required parking spaces.
The motion was seconded by Thompson and passed unanimously.
Old Business
8a. Rural Residential Small Lot Zoning Ordinance
Keller provided information on the ongoing process of creating a Rural Residential Small Lot Zoning
Classification.
Commission discussion focused on whether or not to set a maximum square footage limit on unattached
accessory structures.
Hazen opened the public hearing at 6:41PM
Joe Walz asked the Commission questions regarding the proposed maximum size requirements.
Hazen closed the public hearing at 6:42PM.
Hazen made a motion to approve Drafted Ordinance Option 1 PC ORD 2026-001. The motion was
seconded by Mick and passed unanimously.
9a. Other Business
Updates provided on: Possible Council action on moratoriums on data centers and multi-family housing, a
site visit to see modular homes in Paynesville, a failed bond request for expanding industrial zone for more
plots, upcoming Council Strategic visioning session, Monastery ground breaking, Hansen & Co. open
house, Interstate Bearings open house, 24 North Lofts CIC plat, new Community Development Intern Grant
Hellermann.
Adjourn: Hazen moved to adjourn the meeting at 6:47PM. The motion was seconded by Mooney
and Thompson and passed unanimously.
Minutes approved by:
Nate Keller
Community Development Director
3
Planning Commission Agenda Items: 7a and
7b
MEETING DATE:
AGENDA ITEM:
ACTION REQUESTED:
July 13th, 2026
7a and 7b
7a – approval on resolution PC2026-009
7b - none
PREVIOUS PLANNING COMMISSION ACTION:
7a – Planning Commission originally approved the Conditional Use Permit unanimously at the October
9th , 2023 Planning Commission. A public hearing was conducted at this meeting (no one spoke). The
item was then approved by the Council. An extension was then requested in September 2024 as the
C.U.P. was set to expire in Nov of 2024. The extension extended the permit to Oct. 31st, 2026.
7b – none this was a Council directed and approved item
BACKGROUND INFORMATION:
7a – Summit Commons is seeking an second extension to their C.U.P. permit. Original permit was
approved in 2023 and then extended in 2024 to Oct. 31st 2026. The requested extension is for an
additional two years which would push out the C.U.P. until Oct. 31st, 2028. It should be noted that the
applicant has done some of the required plantings of the Wobegon trail so some progress has been made.
The additional two years will also allow more time for the plantings to grow. The applicant has submitted
a letter stating the request and reasonings.
7b – At the June 15th Council meeting the Council approved two moratoriums.
The first is a moratorium on multi-family housing within properties that are zoned R-3 or
proposed to be rezoned to R-3. The moratorium is set to last for one year unless Council repeals it
before one year. More information will be provided to Commission at the meeting.
The 2nd moratorium is for Data Centers. The moratorium prevents any projects that would
propose a land use application for a Data Center (as defined in the moratorium) in moving
forward during the duration of the moratorium. More information will be provided to
Commission at the meeting.
ATTACHMENTS:
Resolution PC2026-009
Original plans for C.U.P.
4
June 8, 2026
Sent via U.S. Mail, Certified Mail, and Posted
Nate Keller
Community Development Director
75 Callaway Street East
St. Joseph, MN 56374
Re: Conditional Use Permit Extension Request – Summit Commons, LLC
Dear Mr. Keller,
My name is Mark Lambert, and I am the owner of Summit Commons, LLC, a Minnesota
limited liability company. On November 6th, 2023, the St. Joseph City Council approved a
Conditional Use Permit for Outdoor Storage at the following locations:
Parcel ID of properties: 84.53400.0006 and 84.53430.0042.
The project we have planned will not be completed prior to the current expiration date of
October 31st, 2026. Summit Commons, LLC is currently managing multiple active projects that
have impacted the scheduling and allocation of available resources necessary to complete this
project within the approved time frame. I am asking the St. Joseph Panning Commission and City
Council to extend the Conditional Use Permit until October 31st, 2028. If granted this extension,
we will be able to deliver a project that both helps the City of St. Joseph and makes more financial
sense to us.
Thank you for your consideration. If you would like to speak with me further regarding
this request, please feel free to contact me directly at (651) 689-2200.
Best regards,
Summit Commons, LLC
By Mark Lambert
Its Owner
5
RESOLUTION PC2026-009
CONDITIONAL USE PERMIT APPROVAL EXTENSION FOR
SUMMIT COMMONS LLC
WHEREAS, SUMMIT COMMONS LLC (applicant and owner) was approved a Conditional Use Permit
to operate Outdoor storage per resolution 2023-059 on the Subject property described in exhibit A:
FINDINGS OF FACT
WHEREAS, On October 9th, 2023 the St. Joseph Planning Commission conducted a public hearing to
consider the application of Summit Commons, LLC., owner and applicant, for a Conditional Use permit
for Outdoor Storage on the Subject Property; and
WHEREAS, That the matter was duly published and notice was posted in the city designated newspaper
and mailed notices were sent to the property owners within three-hundred and fifty (350) feet of the
Subject Property; and
WHEREAS, That the Subject Property is zoned B3- General Business District and Outdoor Storage is
allowed through a Conditional Use Permit; and
WHEREAS, the St. Joseph Planning Commission recommended approval of the Finding of Fact
Resolution at their October 9th, 2023 meeting; and
WHEREAS, the Conditional Use Permit was set to expire on October 31st, 2026; and
WHEREAS, the applicants have requested that the permit be extended until October 31st, 2028; and
NOW, THEREFORE BE IT RESOLVED THAT THE CITY COUNCIL OF ST. JOSEPH,
MINNESOTA, HEREBY RECOMMENDS APPROVAL TO EXTEND THE CONDITIONAL
USE PERMIT AND THE FOLLOWING CONDITIONS OF APPROVAL SHALL APPLY:
1. All conditions outlined on the original City Council resolution 2024-055 approving the
Conditional Use Permit shall be adhered to except now the date the Conditional Use Permit
expires will be October 31st, 2028.
6
WHEREAS said Finding of Fact and Decision was declared duly passed and adopted by the St.
Joseph City Council on this 20th day of July 2026.
CITY OF ST. JOSEPH
ATTEST
Mayor, Adam Scepaniak
David Murphy, City Administrator
Document drafted by:
City of St. Joseph
EXHIBIT
A - -St- E
SITE PLAN
75 Callaway
St. Joseph, MN 56374
7
Exhibit A
PARCEL 1
Lots One (1) and Two (2) in Schneider's Addition, according to the plat and the survey thereof on file
and on record in the office of the County Recorder in and for Steams County, Minnesota.
ALSO an unplatted tract of land lying North of Lot 1, Schneider's Addition and being part of the West
Half of the Northwest Quarter (W ½NW¼) of Section Ten (10), in Township One Hundred Twentyfour (124) North, of Range Twenty-nine (29) West, according to the U.S. Government Survey thereof,
Steams County, Minnesota, described as follows: Beginning at a point 292.38 feet north of the North
line of Pine Street (now Birch Street) and 150 feet West of the West Line of San Francisco Street (now
First Avenue N.W.) in the Village of St. Joseph, and running thence North parallel to the West line of
San Francisco Street aforesaid until its intersection with the Southerly right of way line of the Great
Northern Railway; thence running Southeasterly along said Southerly right of way line, until its
intersection with the Westerly line of San Francisco Street in the Village of St. Joseph; thence Southerly
along the Westerly line of San Francisco Street aforesaid, to a point directly East of the point of
beginning, and thence Westerly to the point of beginning, except that portion of land hereinbefore sold
to the Village of St. Joseph set forth in Book 122 of Deeds, page 288, described as follows:
Beginning at a point in the Northwest Quarter of the Northwest Quarter (NW¼ NW¼) of Section 10,
from which the Quarter-Quarter comer on West side of Northwest Quarter of Section 10, Township
124, Range 29 bears South 25 degrees West 484 feet; thence from said point of beginning North 6
degrees 30 minutes East 13 8 feet to the Railroad right of way; thence South 51 degrees East 261 feet
along said Railroad right of way and thence north 83 degrees West 221 feet to the point of beginning
and being a part of the NW ¼ NW¼ of Section 10, Township 124, Range 29.
ALSO Excepting that portion of land sold to Christ Stich and Joseph Reber as set forth in Book 172 of
Deeds, page 306 described as follows:
Lot 1, in Block 2 of Loso's 6th Addition to Village of St. Joseph, Steams County, Minnesota; also the
following tract of land, to-wit: Beginning at a point on the Southerly right of way line of the Great
Northern Railroad in Section 10, Township 124, Range 29 where a line parallel to and 44 feet east of
the West line of Section 10, Township 124, Range 29 intersects said Southerly right of way line; thence
South parallel to said Section line 274 feet; thence South 83 degrees East 182 feet more or less, to the
Southwest comer of the Village Gravel pit; thence north 6 degrees 30 minutes East along the Westerly
line of said Village Gravel Pit 137 feet to the Southerly right of way line of the Great Northern Railroad;
8
thence Northwesterly along said Southwesterly right of way line of the Great Northern Railroad 256
feet, more or less, to the point of beginning.
PARCEL 2
That part of the NE ¼ of the NE ¼ of Section 9 and that part of said NW ¼ of the NW ¼ of Section 10
bounded as follows: on the East by the West line of Schneider's Addition, a duly recorded plat, produced
Northerly; on the South by a line drawn due West from a point of said West line of said plat distant
800.00 feet Northerly from its intersection with the Northerly right of way line of U.S. Trunk Highway
52; on the West by a line drawn parallel with and 150.00 feet Westerly of, measured at right angles to.
said West line of said plat; and on the North by the South line of the North 880.42 feet of said Section
9 and 10.
ALSO
That part of the South 451.42 feet of the North 880.42 feet of the North 880.42 feet of the East 686.70
feet of Northeast Quarter of Section 9, Township 124, Range 29, Stearns County, Minnesota, which
lies southwesterly right of way line of the Burlington Northern Railroad.
Parcel ID of properties: 84.53400.0006 and 84.53430.0042
9
TR
L
SYMBOL LEGEND
REMOVE AND DISPOSE OF
GRAVEL SECTION
B-1
WD: 5'-6"
REMOVE AND DISPOSE OF
CONCRETE PAVEMENT SECTION
B-22
WD: 5'-0"
B-xx
WD: xxx
APPROXIMATE BORING LOCATION
(WD: MEASURED WATER TABLE DEPTH)
DEMOLITION NOTES
B-2
WD: 5'-2"
1. Verify all existing utility locations.
2. It is the responsibility of the Contractor to perform or coordinate all necessary
utility demolitions and relocations from existing utility locations to all onsite
amenities and buildings. These connections include, but are not limited to, water,
sanitary sewer, cable tv, telephone, gas, electric, site lighting, etc.
B-11
WD: 3'-0"
B-21
WD: 2'-6"
B-4
WD: 5'-5"
B-8
WD: 3'-8"
B-3
WD: 5'-3"
B-16
WD: 4'-0"
B-10
WD: 4'-0"
B-9
WD: 5'-0"
B-17
WD: 5'-0"
KEY NOTES
B-12
WD: 3'-0"
B-5
WD: 3'-9"
1
REMOVE AND DISPOSE OF GRAVEL SECTION.
2
REMOVE AND DISPOSE OF CONCRETE PAVEMENT SECTION.
3
EXISTING OVERHEAD ELECTRIC AND POLES TO BE REMOVED. COORDINATE WITH THE
LOCAL UTILITY PROVIDER FOR REMOVAL AND/OR RELOCATION OF ELECTRICAL SERVICES.
2
B-7
WD: 3'-6"
B-15
WD: 4'-0"
B-14
WD: 4'-0"
2
3
E
OH
B-13
WD: 4'-0"
B-6
WD: 3'-10"
1
E
OH
B-18
WD: 4'-6"
E
OH
APPROXIMATE WETLAND LIMITS
PER STEARNS COUNTY GIS MAP
3
E
OH
1
Client:
5. All construction shall be performed in accordance with state and local standard
specifications for construction.
Project Title:
4. Sawcut along edges of pavements, sidewalks, and curbs to remain.
OH
E
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
3. Prior to beginning work, contact Gopher State Onecall (651-454-0002) to locate
utilities throughout the area under construction. The Contractor shall retain the
services of a private utility locator to locate the private utilities.
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
AI
C 2023 Larson Engineering, Inc. All rights reserved.
PROPERTY LINE
SETBACK LINE
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
ON
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
EG
Engineering, Inc.
GENERAL
Larson
W
OB
SUMMIT
COMMONS LLC
E
ST. JOSEPH RV AND
OUTDOOR STORAGE
LA
K
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
OH
E
APPROX. 100-YR FLOODPLAIN
PER STEARNS COUNTY GIS &
FEMA FIRM MAP
B-19
WD: 5'-0"
Date: xx.xx.23
Rev.
Lic. No.:
Date
54950
Description
OH
E
3
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
Issue Date:
1
xx.xx.2023
Sheet Title:
DEMOLITION PLAN
B-20
WD: 5'-0"
Sheet:
NORTH
0
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C100 - Demo.dwg
10
20
40
80
C100
EG
ON
4
TR
AI
L
SYMBOL LEGEND
40
'
26'
35'
PROPERTY LINE
SETBACK LINE
6
NEW COMPACTED
BITUMINOUS RECLAIM
DETAIL 1/C500
1
32
'
32'
1
4
NEW STORMWATER POND AND WET AREA SEED MIX
(MNDOT 33-261)
40'
C 2023 Larson Engineering, Inc. All rights reserved.
OB
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
6
6
GENERAL
W
Engineering, Inc.
E
4
Larson
LA
K
NEW CHAIN LINK FENCE WITH
BLACK PRIVACY SLATS
DETAIL 4/C500
4
NEW LIGHT POLE,
SEE ELECTRICAL
35'
4
=
=
=
=
=
73 SPACES
131 SPACES
26 SPACES
7 SPACES
237 SPACES
1
NOTE: STORAGE COUNTS ABOVE ARE APPROXIMATE. ACTUAL COUNTS
MAY VARY DEPENDING ON FINAL STRIPING LAYOUT & STALL SIZES
DETERMINED IN THE FIELD.
32'
1
6
1
32'
1
KEY NOTES
6
40'
32'
STORMWATER BASIN
24'
12'
4
40'
1
NEW COMPACTED BITUMINOUS RECLAIM, DETAIL 1/C500
2
NEW SURMOUNTABLE CURB AND GUTTER, DETAIL 2/C500
3
NEW RETAINING WALL, DETAIL 3/C500
4
NEW 8' CHAIN LINK FENCE WITH PRIVACY SLATS, DETAIL 4/C500
5
NEW BLUE SPRUCE TREE (OR AS APPROVED BY OWNER), 16 TOTAL.
DETAIL 5/C500.
4
NOTE: ALTERNATE SCREENING LOCATION SHOWN WITHIN DASHED
AREA. APPLICANT SHALL ATTEMPT TO LOCATE TREES IN THE COUNTY
RIGHT-OF-WAY ASSUMING IT IS FEASIBLE AND NECESSARY PERMITS
CAN BE OBTAINED.
6
40'
6
6
NEW LIGHT POLE, SEE ELECTRICAL
7
NEW CARDED ENTRY/EXIT SECURITY GATE
35'
4
1
20'
4
4
2
4
APPROXIMATE WETLAND LIMITS
PER STEARNS COUNTY GIS MAP
35'
6
40'
32'
4
Client:
12' x 40' PULL THROUGH
12' x 40' STANDARD
12' x 26' STANDARD
12' x 20' STANDARD
TOTAL
Project Title:
80'
6
6
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
STORAGE SPACES
1
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
TYP 16
5
SUMMIT
COMMONS LLC
1
6
1
32'
'
12 .
P
Y
T
ALTERNATE SCREENING
LOCATION, SEE
KEYNOTE #5
ST. JOSEPH RV AND
OUTDOOR STORAGE
32'
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
NEW GENERAL SEED MIX
(MNDOT SEED MIX 25-141)
6
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
2
APPROX. 100-YR FLOODPLAIN
PER STEARNS COUNTY GIS &
FEMA FIRM MAP
Date: xx.xx.23
Rev.
1
Lic. No.: 54950
Date
Description
4
6
10'
12236025.000
Drawn By:
NJN
Checked By: BDM
4
7
4
Project #:
Issue Date:
xx.xx.2023
Sheet Title:
1
2
SITE PLAN
20'
Sheet:
NORTH
3
0
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C200 - Paving.dwg
11
20
40
80
C200
950.00 TC
949.50 GL
69.53 B
70
SPOT ABBREVIATIONS:
TC - TOP OF CURB
GL - GUTTER LINE
GO - GUTTER OUT
B - BITUMINOUS
C - CONCRETE
EO - EMERGENCY OVERFLOW
TW - TOP OF WALL
BW - BOTTOM OF WALL (F/G)
(*) - EXISTING TO BE VERIFIED
All elevations with an asterisk (*) shall be field verified. If elevations vary
significantly, notify the Engineer for further instructions.
3.
Grades shown in paved areas represent finish elevation.
4.
All disturbed areas to receive 4” of good quality topsoil and seed.
5.
All construction shall be performed in accordance with state and local standard
specifications for construction.
6.
Coordinate with City for driveway connection and including minor grade
adjustments as needed.
70
69.93 B
1069
1068
KEY NOTES
69.93 B
70
NEW STORMWATER BASIN, DETAIL 6/C500
69.21 B
68.98 B
69
106
7
69
69
1
68.78 B
56
57
58
59
60
61
62
63
64
65
66
67
68
69 69
67
68
69
67
66
1068
1069
68.10 EOF
67.85 TC/GL
64.5
65.5
68.39 B
BASIN-1
100-YR HWL: 67.83
10-YR HWL: 66.99
2-YR HWL: 66.53
NWL: 65.50
BOT: 56.00
68
69.22 B
1
69.00 B
68.53 B
APPROXIMATE WETLAND LIMITS
PER STEARNS COUNTY GIS MAP
68
68
67
66
65
3:1
APPROX. 100-YR FLOODPLAIN
PER STEARNS COUNTY GIS &
FEMA FIRM MAP
Client:
2.
Project Title:
Tree protection consisting of snow fence or safety fence installed at the drip line
shall be in place prior to beginning any grading or demolition work at the site.
69
1.
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
GRADING NOTES
C 2023 Larson Engineering, Inc. All rights reserved.
2.0%
EXISTING CONTOURS
PROPOSED CONTOURS - MAJOR INTERVAL
PROPOSED CONTOURS - MINOR INTERVAL
GRADE BREAK LINE
GRADE SLOPE
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
950
950
949
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
SYMBOL LEGEND
1076
1075
1074
1073
1072
1071
1070
1069
Engineering, Inc.
TR
AI
L
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
70
70.33 B
PROPERTY LINE
SETBACK LINE
Larson
68
ON
106
7
2:1
PE
SLO
69
OB
EG
71
70.72 B
82
81 79
80 78 6
77 75 7 3
74 72 7
1079
71
1077
1078
70.72 B
70
SUMMIT
COMMONS LLC
71
GENERAL
W
ST. JOSEPH RV AND
OUTDOOR STORAGE
LA
KE
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
Lic. No.:
54950
69
Date: xx.xx.23
Date
Description
70
Rev.
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
Issue Date:
xx.xx.2023
Sheet Title:
70.18 TW/BW/B
69
GRADING
PLAN
74.30 TW
70.30 BW/B
69.86 TC
69.53 GL
Sheet:
69.56 TW/BW/B
69.56 TC/GL
NORTH
69.95 B
SEE GRADING NOTE #6
0
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C300 - Grading.dwg
12
20
40
80
C300
6
68
70
69
1070
PROPERTY LINE
SETBACK LINE
2
ROCK CONSTRUCTION ENTRANCE, DETAIL 2/C501
3
EROSION CONTROL BLANKET, DETAIL 3/C501
4
RIP-RAP AT FES, DETAIL 4/C501
SEDIMENT LOG, DETAIL 1/C501
5
RIP-RAP AT OUTLET, DETAIL 5/C501
RIP-RAP / ROCK CONST. ENTRANCE
DETAILS 2/C501, 4/C501, 5/C501, & 6/C501
1075
6
3:1 OR STEEPER SLOPES NOT TO BE DISTURBED
1073
7
RIP-RAP, DETAIL 6/C501
71
ON
TR
AI
L
106
7
3
3 1076
1072
OB
EG
SEDIMENT LOG, DETAIL 1/C501
82
81 79
80 78 6
77 75 7 3
74 72 7
1079
71
1077
1078
1074
70
1
71
SYMBOL LEGEND
1071
EROSION CONTROL BLANKET
DETAIL 3/C501
CONCRETE WASHOUT STATION
(LOCATE DURING CONSTRUCTION)
1
All construction site entrances shall be surfaced with crushed rock across the entire width of the entrance and from the entrance to
a point 50' into the construction zone.
5.
The toe of the silt fence shall be trenched in a minimum of 6”. The trench backfill shall be compacted with a vibratory plate
compactor.
6.
All grading operations shall be conducted in a manner to minimize the potential for site erosion. Sediment control practices must
be established on all down gradient perimeters before any up gradient land disturbing activities begin.
70
1069
7.
All exposed soil areas must be stabilized as soon as possible to limit soil erosion but in no case later than 7 days after the
construction activity in that portion of the site has temporarily or permanently ceased. Temporary stockpiles without significant silt,
clay or organic components (e.g., clean aggregate stockpiles, demolition concrete stockpiles, sand stockpiles) and the constructed
base components of roads, parking lots and similar surfaces are exempt from this requirement.
1068
8.
The normal wetted perimeter of any temporary or permanent drainage ditch or swale that drains water from any portion of the
construction site, or diverts water around the site, must be stabilized within 200 lineal feet from the property edge, or from the point
of discharge into any surface water. Stabilization of the last 200 lineal feet must be completed within 24 hours after connecting to a
surface water. Stabilization of the remaining portions of any temporary or permanent ditches or swales must be complete within 7
days after connecting to a surface water and construction in that portion of the ditch has temporarily or permanently ceased.
9.
Pipe outlets must be provided with energy dissipation within 24 hours of connection to surface water.
6
3
1
70
3
10. All riprap shall be installed with a filter material or soil separation fabric and comply with the Minnesota Department of
Transportation Standard Specifications.
3
69
106
7
69
69
BLOCK BASIN OUTLET UNTIL ALL
UPSTREAM AREAS HAVE BEEN STABILIZED
4
66
69
67
68
3
3
1
1069
1
5
PROVIDE TEMPORARY
OUTLET AT 61.55
12. All storm sewer catch basins not needed for site drainage during construction shall be covered to prevent runoff from entering the
storm sewer system. Catch basins necessary for site drainage during construction shall be provided with inlet protection.
7
6
64.5
13. In areas where concentrated flows occur (such as swales and areas in front of storm catch basins and intakes) the erosion control
facilities shall be backed by stabilization structure to protect those facilities from the concentrated flows.
65.5
1
14. Inspect the construction site once every seven days during active construction and within 24 hours after a rainfall event greater
than 0.5 inches in 24 hours. All inspections shall be recorded in the SWPPP.
6
68
3
1068
1
56
57
58
59
60
61
62
63
64
65
66
67
68
69 69
67
11. All storm sewers discharging into wetlands or water bodies shall outlet at or below the normal water level of the respective wetland
or water body at an elevation where the downstream slope is 1 percent or flatter. The normal water level shall be the invert
elevation of the outlet of the wetland or water body.
3
15. All BMPs must be repaired, replaced, or supplemented when they become nonfunctional or the sediment reaches 1/3 of the
capacity of the BMP. These repairs must be made within 24 hours of discovery, or as soon as field conditions allow access. All
repairs shall be recorded in the SWPPP.
1
16. If sediment escapes the construction site, off-site accumulations of sediment must be removed in a manner and at a frequency
sufficient to minimize off-site impacts.
APPROXIMATE WETLAND LIMITS
PER STEARNS COUNTY GIS MAP
6
17. All soils tracked onto pavement shall be removed daily.
18. All infiltration areas must be inspected to ensure that no sediment from ongoing construction activity is reaching the infiltration area
and these areas are protected from compaction due to construction equipment driving across the infiltration area.
68
19. Temporary soil stockpiles must have silt fence or other effective sediment controls, and cannot be placed in surface waters,
including stormwater conveyances such as curb and gutter systems, or conduits and ditches unless there is a bypass in place for
the stormwater.
1
6
68
67
66
65
4
20. Collected sediment, asphalt and concrete millings, floating debris, paper, plastic, fabric, construction and demolition debris and
other wastes must be disposed of properly and must comply with MPCA disposal requirements.
3:1
69
APPROX. 100-YR FLOODPLAIN
PER STEARNS COUNTY GIS &
FEMA FIRM MAP
21. Oil, gasoline, paint and any hazardous substances must be properly stored, including secondary containment, to prevent spills,
leaks or other discharge. Restricted access to storage areas must be provided to prevent vandalism. Storage and disposal of
hazardous waste must be in compliance with MPCA regulations.
3
22. External washing of trucks and other construction vehicles must be limited to a defined area of the site. Runoff must be contained
and waste properly disposed of. No engine degreasing is allowed onsite.
6
6
1.
Dewatering shall take place after sediment has settled to the bottom of the basin.
2.
Contractor shall prevent erosion and scour at discharge points through the use of an energy dissipation device.
Dewatering must avoid nuisance conditions in receiving waters.
4.
Dewatering must not inundate downstream wetlands.
7.89
28,404
28,741
3
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C300 - Grading.dwg
13
54950
Description
12236025.000
25. All permanent sedimentation basins must be restored to their design condition immediately following stabilization of the site.
Drawn By:
NJN
1.
69
Provided Temporary
Storage (CF)
Date
Project #:
Issue Date:
Permittees must not cause nuisance conditions (see Minn. R. 7050.0210, subp. 2) in surface
waters from dewatering and and basin draining (e.g., pumped discharges, trench/ditch cuts
for drainage) discharges. Permittees must discharge turbid or sediment-laden waters related
to dewatering or basin draining to a sediment control (e.g. sediment trap or basin, filter bag)
designed to prevent discharges with visual turbidity. To the extent feasible, use well
vegetated (e.g. grassy or wooded), upland areas of the site to infiltrate dewatering water
before discharge. Permittees are prohibited from using receiving waters as part of the
treatment area. Permittees must visually check and photograph the discharge at the
beginning and at least once every 24 hours of operation to ensure adequate treatment has
been obtained and nuisance conditions will not result from the discharge. [Minn. R.
0
7050.0210]
xx.xx.2023
Sheet Title:
DEWATERING NOTES
Required Minimum
Temporary Storage (CF)
Rev.
Lic. No.:
24. Upon completion of the project and stabilization of all graded areas, all temporary erosion control facilities (silt fences, hay bales,
etc.) shall be removed from the site.
2
Drainage Area (Acres)
Date: xx.xx.23
23. All liquid and solid wastes generated by concrete washout operations must be contained in a leak-proof containment facility or
impermeable liner. A compacted clay liner that does not allow washout liquids to enter ground water is considered an impermeable
liner. The liquid and solid wastes must not contact the ground, and there must not be runoff from the concrete washout operations
or areas. Liquid and solid wastes must be disposed of properly and in compliance with MPCA regulations. A sign must be installed
adjacent to each washout facility to inform concrete equipment operators to utilize the proper facilities.
26. Contractor shall submit Notice of Termination for MPCA-NPDES permit within 30 days after Final Stabilization.
6
Temporary Sediment Basin Volumes
Bryan D. Miller, P.E.
Checked By: BDM
6
3.
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
70
1
TEMPORARY BASIN DEWATERING AND BASIN DRAINING
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
4.
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
Erosion control measures shown on the erosion control plan are the absolute minimum. The contractor shall install temporary
earth dikes, sediment traps or basins, additional siltation fencing, and/or disk the soil parallel to the contours as deemed necessary
to further control erosion. All changes shall be recorded in the SWPPP.
SUMMIT
COMMONS LLC
3.
ST. JOSEPH RV AND
OUTDOOR STORAGE
Install temporary erosion control measures (inlet protection, silt fence, and rock construction entrances) prior to beginning any
excavation or demolition work at the site.
69
6
2.
Client:
70
Owner and Contractor shall obtain MPCA-NPDES permit. Contractor shall be responsible for all fees pertaining to this permit. The
SWPPP shall be kept onsite at all times.
Project Title:
1069
1.
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
EROSION CONTROL NOTES
Basin #1
C 2023 Larson Engineering, Inc. All rights reserved.
6
GENERAL
KEY NOTES
W
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
6
Engineering, Inc.
LA
KE
6
Larson
6
EROSION
CONTROL PLAN
Sheet:
NORTH
20
40
80
C301
EG
ON
PROPERTY LINE
SETBACK LINE
TR
AI
L
SYMBOL LEGEND
STORM MANHOLE (STMH)
DETAIL 7/C500
FLARED END SECTION (FES)
DETAIL 8/C500
STORM SEWER PIPE
C 2023 Larson Engineering, Inc. All rights reserved.
GENERAL
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
W
OB
Engineering, Inc.
E
Larson
LA
K
4.
The contractor shall notify all appropriate engineering departments and utility companies 72 hours prior to
construction. All necessary precautions shall be made to avoid damage to existing utilities.
5.
Storm sewer requires testing in accordance with Minnesota plumbing code 4714.1109 where located
within 10 feet of waterlines or the building.
6.
HDPE storm sewer piping shall meet ASTM F2306 and fittings shall meet ASTM D3212 joint pressure
test. Installation shall meet ASTM C2321.
7.
See Project Specifications for bedding requirements.
KEY NOTES
1
NEW STORM MANHOLE, DETAIL 7/C500
2
NEW FLARED END SECTION, DETAIL 8/C500
3
NEW WEIR, DETAIL 9/C500
STORMWATER BASIN
2
FES
INV: 58.00
E
DP
"H %
18 .36
LF 11
66 @
STMH-1
1
3
RIM: 68.90
TOP OF WEIR: 66.60
8" ORIFICE: 65.50
INV (NW,S): 65.50
119 LF 18" HDPE @ 0.42%
APPROXIMATE WETLAND LIMITS
PER STEARNS COUNTY GIS MAP
2
FES
INV: 65.00
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
The contractor shall verify the elevations at proposed connections to existing utilities prior to any
demolition or excavation.
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
3.
SUMMIT
COMMONS LLC
All service connections shall be performed in accordance with state and local standard specifications for
construction. Utility connections (sanitary sewer, watermain, and storm sewer) may require a permit from
the City.
ST. JOSEPH RV AND
OUTDOOR STORAGE
2.
Client:
It is the responsibility of the contractor to perform or coordinate all necessary utility connections and
relocations from existing utility locations to the proposed building, as well as to all onsite amenities.
These connections include but are not limited to water, sanitary sewer, cable TV, telephone, gas, electric,
site lighting, etc.
Project Title:
1.
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
UTILITY NOTES
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
APPROX. 100-YR FLOODPLAIN
PER STEARNS COUNTY GIS &
FEMA FIRM MAP
Date: xx.xx.23
Rev.
Lic. No.:
Date
54950
Description
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
Issue Date:
xx.xx.2023
Sheet Title:
UTILITY PLAN
Sheet:
NORTH
0
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C400 - Utility.dwg
14
20
40
80
C400
MANHOLE STEPS SHALL BE PLACED
SO THAT OFFSET HOLE IN TOP SLAB
IS FACING DOWNSTREAM.
TOP RAIL
TENSION BANDS SPACED
MAXIMUM OF 15" APART
MIDDLE RAIL
8'
NO BLOCK STRUCTURES ARE ALLOWED
TENSION BAR
APPROVED SUBGRADE SOIL
1"
COMPACTED BITUMINOUS
RECLAIM SECTION
GRADE 1" BELOW 10' TRANSITION.
SUMMIT
COMMONS LLC
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
12"
PLAN
6"
APPROVED SUBGRADE SOIL
1'-4"
ALL JOINTS IN MANHOLE TO HAVE
'O' RING RUBBER GASKETS.
FENCE DETAIL
4
C500
SEAL WITH 2 BEADS OF RAM-NEK.
NOT TO SCALE
OPTIONAL STAKING METHOD - 6' METAL
POSTS AND RUBBER HOSE STRAPS
SURMOUNTABLE CURB
& GUTTER DETAIL
VARIABLE
CONIFEROUS TREE (8' HEIGHT MIN)
AS PER SCHEDULE
NOT TO SCALE
3 GUYS EACH OF 10 GAUGE TWISTED
WIRE 120° APART AROUND TREE
DECIDUOUS TREE (2.5" Ø MIN)
AS PER SCHEDULE
VARIES
SECTION
6" DEEP MULCH, HOLD
BACK 2" FROM STEM.
COLORED FLAGS
1 PER WIRE
SOD/SEED
(SEE PLANS)
12"MIN.
NEW MODULAR BLOCK
NEW COMPACTED
BITUMINOUS RECLAIM
BURLAP SHOULD BE REMOVED
18"
MIN.
EQUALS TWICE BALL
DIAMETER
RETAINING WALL BASE, DRAINTILE, AND AGGREGATE
BACKFILL PER MANUFACTURER'S RECOMMENDATION.
5
C500
WATERTIGHT CONNECTION
(BOOT/GROUT RING, TYPICAL)
STORM
MANHOLE DETAIL
7
C500
BW (SEE GRADING PLAN)
TOP 31 OF WIRE CAGE AND
8" MINIMUM SLAB THICKNESS,
6' MINIMUM DIAMETER PRECAST
CONCRETE SLAB, REINFORCED
WITH #4 REBAR @ 8" E.W.
GROUT BOTTOM
TURNBUCKLE
BACKFILL WITH NEW
GOOD QUALITY
TOPSOIL AND SEED
8" PRECAST SEGMENTAL CONCRETE BLOCK
TO TOP OF THE PIPE SHALL BE USED
WITH SIZE AND DEPTH PROHIBIT THE
FABRICATION OF PRECAST UNITS.
8"
NEW WALL CAP
PRECAST CONCRETE SECTION
PE
PI IA.
D
HOSE LOOPS
TW (SEE GRADING PLAN)
MANHOLE STEPS, COPOLYMER POLYPROPYLENE
PLASTIC, WITH 1/2" GRADE 60 STEEL
REINFORCEMENT OR EQUAL, 16" O.C.
5" MIN.
VARIABLE
NEW BASE
AGGREGATE
6"
6" PRECAST REINFORCED CONCRETE SLAB.
NOTES:
1. FENCE FABRIC AND PRIVACY SLAT COLOR/STYLE TO BE REVIEWED AND APPROVED BY OWNER
PRIOR TO CONSTRUCTION.
1.125"
6"
12" DIA. X 5' CONCRETE
FOOTING (TYPICAL)
NOT TO SCALE
24" STAKE TYP.
PLACE PLANTING
MEDIUM SOILS
18" HDPE
INV: 65.50
SCARIFY ALL SIDES AND
BOTTOM OF EXCAVATED HOLE
TREE PLANTING DETAIL
NOT TO SCALE
6"
5
8" SMOOTH BAR @
2" O.C. EACH WAY
24"MAX
NOTES:
1. WALL TO BE DESIGNED/INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
2. WALL TYPE, COLOR, TEXTURE TO BE SELECTED BY OWNER.
Client:
7"
10.75"
MINIMUM OF 2, MAXIMUM OF 5
CONCRETE ADJUSTMENT RINGS WITH FULL
BED OF MORTAR BETWEEN EACH AND
A 4" COLLAR ON THE OUTSIDE. NO SHIMS
OF ANY MATERIAL ALLOWED.
INSTALL NEW EXTERNAL CHIMNEY SEAL.
Project Title:
NEW COMPACTED
BITUMINOUS RECLAIM
SLOPE
3 " PER FT.
4
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
12"
4'-6"
NOT TO SCALE
BACKFILL WITH NEW
GOOD QUALITY
TOPSOIL AND SEED
2
C500
ST. JOSEPH RV AND
OUTDOOR STORAGE
MANHOLE FRAME & COVER:
NEENAH R-1642, TYPE B LID (STMH, SOLID CLOSED, CIRCLE)
*UNLESS OTHERWISE NOTED
5'
1
C500
BOTTOM RAIL
C 2023 Larson Engineering, Inc. All rights reserved.
PRECAST INVERT SHOULD BE 1/2
DIAMETER OF PIPE AND BENCHES
SLOPED 2" TOWARD INVERT.
3" O.D.
LINE POST
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
BLACK PRIVACY SLATS
Larson
3" O.D. TERMINAL POST
Engineering, Inc.
BLACK VINYL CHAIN LINK
FENCE FABRIC
10' MAX
NEW 8" COMPACTED
BITUMINOUS RECLAIM
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
SEGMENTAL RETAINING
WALL DETAIL
3
C500
Date: xx.xx.23
6"MAX
Rev.
Lic. No.:
Date
54950
Description
NOT TO SCALE
TOP OF WEIR: 66.60
PE
(3 R P
:1
M LAN
AX
)
18" HDPE
INV: 65.50
AN
PL X)
A
R
PE :1 M
3
(
OUTL
NORMAL WATER LEVEL
10:1 (SAF
ETY BENC
H)
H)
ETY BENC
10:1 (SAF
3:
1
FES W/ TRASH GUARD
ET PIP
E
E
INLET PIP
PROVIDE 3 CLIPS TO FASTEN TRASH GUARD TO F.E.S.
HOT DIP GALVANIZE AFTER FABRICATION.
1
3:
POND BOTTOM
8
C500
EXISTING SOILS
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
FLARED END
SECTION DETAIL
Issue Date:
xx.xx.2023
Sheet Title:
8" ORIFICE INV: 65.50
NOT TO SCALE
DETAILS
6
C500
BOTTOM OF STRUCTURE: 65.50
WET SEDIMENTATION BASIN
CROSS SECTION
9
C500
NOT TO SCALE
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C500 - Details.dwg
15
STMH - 1
WEIR DETAILS
NOT TO SCALE
Sheet:
C500
4
B
1
B
10'
2'
GROUND
FLOW
A
A
35'
D
D
R
HA
1
E
AC
S
IC
6"
F
UR
AD
RO
50
'
L
UB
P
GEOTEXTILE
FABRIC
PLACE RIP RAP ON
6 INCHES OF 2 INCH
ROCK BEDDING OVER
GEOTEXTILE FABRIC
4D
MN/DOT CLASS III
RIP-RAP
GEOTEXTILE
FABRIC
PLACE RIP RAP ON
6 INCHES OF 2 INCH
ROCK BEDDING OVER
GEOTEXTILE FABRIC
CL. II RIP RAP
MI
NIM
5D (10' MIN.)
2'
WOVEN FILTER
FABRIC
2'
UM
CL. II RIP RAP
SECTION A-A
SECTION B-B
SECTION A-A
NOTE:
FW300 MIRAFI FABRIC OR EQUAL
MIN. 6" OF 1" TO
2" DIA ROCK
MNDOT STANDARD SPECIFICATION
3733 TYPE V PERMEABLE
GEOTEXTILE FABRIC BENEATH ROCK
'
20
18" MIN. HIGH CUT-OFF BERM TO
MINIMIZE SILT RUNOFF FROM SITE
RIP-RAP AT OUTLETS
4
C501
N
MI
6
C501
NOT TO SCALE
VARIES:
FULL WIDTH OF EXISTING
DRIVEWAY OPENING OR
20' MIN. WIDTH.
10'
A
B
2
C501
15'
25'
B
ROCK CONSTRUCTION ENTRANCE
NOT TO SCALE
A
15'
PLAN
SLOPE INSTALLATION
2"-5"
(5cm-12.5cm)
4.
15'
(ELEVATION-SEE PLAN)
0.5'
12"
(30 cm)
(EOF-SEE PLAN)
MOUND LAST 2 FEET
OF RIP RAP 1 FOOT DEEP
(TOP OF RIP RAP SHALL BE
LOWER THAN OVERFLOW ELEVATION)
10'
5'
6"
(15 cm)
6"
(15 cm)
2.
EXTEND FABRIC 1 FOOT
BEYOND LIMITS OF
RIP RAP WITH MINIMUM
1 FOOT OF COVER (TYP)
3B.
3A.
GEOTEXTILE
FABRIC
GEOTEXTILE
FABRIC
PLACE RIP RAP ON
6 INCHES OF 2 INCH
ROCK BEDDING OVER
GEOTEXTILE FABRIC
3"
(7.5cm)
PLACE RIP RAP ON
6 INCHES OF 2 INCH
ROCK BEDDING OVER
GEOTEXTILE FABRIC
CL. II RIP RAP
CL. II RIP RAP
SECTION A-A
1.
SECTION B-B
EXTEND FABRIC 1 FOOT
BEYOND LIMITS OF
RIP RAP WITH MINIMUM
1 FOOT OF COVER (TYP)
EXTEND FABRIC 1 FOOT
BEYOND LIMITS OF
RIP RAP WITH MINIMUM
1 FOOT OF COVER (TYP)
RIP-RAP DETAIL
NOT TO SCALE
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
EXTEND FABRIC 1 FOOT
BEYOND LIMITS OF
RIP RAP WITH MINIMUM
1 FOOT OF COVER (TYP)
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
PLAN
NOT TO SCALE
Client:
4
SEDIMENT LOG DETAIL
Project Title:
2'
1
MOUND LAST 2 FEET
OF RIP RAP 1 FOOT DEEP
(TOP OF RIP RAP SHALL BE
LOWER THAN OVERFLOW ELEVATION)
35'
MN/DOT CLASS III
RIP-RAP
SUMMIT
COMMONS LLC
10'
ST. JOSEPH RV AND
OUTDOOR STORAGE
PLAN
WOVEN FILTER
FABRIC
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
24" MIN.
A
NOTES:
1. STAKE OR SAND BAG SPACING SHALL BE 2 FEET O.C.
1
C501
Larson
A
WOOD STAKE TO ONLY
PENETRATE NETTING,
NOT CURLEX MATERIAL
C 2023 Larson Engineering, Inc. All rights reserved.
20'
2'
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
5D (10' MIN.)
2'
Engineering, Inc.
WOOD STAKE OR SAND BAG
20'
8" CURLEX SEDIMENT LOGS
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
1. PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECP's), INCLUDING ANY NECESSARY APPLICATION
OF LIME, FERTILIZER, AND SEED.
NOTE: WHEN USING CELL-O-SEED DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN.
5
C501
TYPICAL RIP RAP
WEIR OVERFLOW
Date: xx.xx.23
Rev.
NOT TO SCALE
Lic. No.:
Date
54950
Description
2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECP's IN A 6" (15 CM) DEEP X 6" (15 CM) WIDE TRENCH
WITH APPROXIMATELY 12" (30cm) OF RECP's EXTENDED BEYOND THE UP-SLOPE PORTION OF THE TRENCH. ANCHOR THE
RECP's WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH.
BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30 CM)
PORTION OF RECP's BACK OVER SEED AND COMPACTED SOIL. SECURE RECP's OVER COMPACTED SOIL WITH A ROW OF
STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) APART ACROSS THE WIDTH OF THE RECP's.
3. ROLL THE RECP's (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. RECP's WILL UNROLL WITH APPROPRIATE SIDE
AGAINST THE SOIL SURFACE. ALL RECP's MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES
IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM , STAPLES/STAKES
SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN.
4. THE EDGES OF PARALLEL RECP's MUST BE STAPLED WITH APPROXIMATELY 2" - 5" (5 CM - 12.5 CM) OVERLAP DEPENDING
ON RECP's TYPE.
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
5. CONSECUTIVE RECP's SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE
3" (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30 CM) APART ACROSS ENTIRE
RECP's WIDTH.
NOTE:
*IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE NECESSARY TO
PROPERLY SECURE THE RECP's.
Issue Date:
xx.xx.2023
Sheet Title:
DETAILS
3
C501
EROSION CONTROL BLANKET
NOT TO SCALE
Sheet:
C501
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C500 - Details.dwg
16
CITY WHERE WORK WILL TAKE PLACE:
COUNTY WHERE WORK WILL TAKE PLACE:
ST. JOSEPH, MN
STEARNS
LATITUDE/LONGITUDE OF APPROXIMATE CENTROID OF PROJECT:
PROJECT TYPE (CIRCLE ONE):
ROAD CONSTRUCTION
RESIDENTIAL
For projects that discharge to trout streams, including tributaries to trout streams, identify method of
incorporating temperature controls into the permanent stormwater management system.
N/A
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Install stabilized rock construction entrances.
Install perimeter erosion control BMP's (silt fence, bio-logs, etc).
Install temporary construction fencing at infiltration areas and other areas not be disturbed.
Install inlet protection throughout project area and downstream inlets.
Construct temporary sediment basins/traps as necessary.
Strip and stockpile topsoil.
Complete rough grading of site.
Stabilize denuded areas and stockpiles.
Install site utilities.
Install temporary inlet protection at newly installed catch basins/inlets.
Install curb and gutter and pavement sections.
Place topsoil and final grading of areas to be vegetated.
Remove accumulated sediment from basins / ponds.
Final grade pond and infiltration areas, including soil de-compaction as specified.
Complete stormwater basin as-built surveys (as required by project specifications and/or local
jurisdictional authorities).
16. Complete permanent stabilization including plantings, seeding, and mulch.
17. Upon completion of construction activity and satisfactory vegetation establishment, remove remaining
temporary erosion and sediment control BMPs.
18. Reseed / restore any areas disturbed during BMP removal.
COMMERCIAL/INDUSTRIAL
DATES OF CONSTRUCTION (ESTIMATED):
Construction start date:
FALL 2023
Construction completion date:
FALL 2024
PROJECT DESCRIPTION:
Construction consists of construction of a new compacted bituminous reclaim/gravel parking lot and
drives, stormwater basin, utilities, and all associated grading/erosion control measures.
PROJECT LIMITS:
See the project plans, in particular the grading & erosion control plans, for site disturbance limits.
SITE DISTURBANCE SUMMARY (to nearest tenth acre):
Total number of acres to be disturbed:
7.4
Pre-Construction acres of impervious:
0.3
Post-Construction acres of impervious:
5.5
Total new impervious acres:
5.2
III. PROJECT PLANS AND SPECIFICATIONS
Refer to the project plans, specifications, geotechnical report, and stormwater calculations which depict various
features that are relevant to this project. Such features may include, but are not limited to, the following:
II. RECEIVING WATERS
RECEIVING WATERS (WITHIN ONE MILE OF PROJECT PROPERTY EDGE):
SPECIAL WATER?
No
4.
45° 34' 18" N, 94° 19' 23" W
RESIDENTIAL & ROAD CONSTRUCTION
TYPE
River
For infiltration systems, provide at least one soil boring, test pit, or infiltrometer test in the location of the
infiltration practice for determining infiltration rates.
N/A
SEQUENCE OF CONSTRUCTION ACTIVITIES
OTHER (DESCRIBE):
NAME OF WATER BODY
Watab River, South Fork
3.
IMPAIRED WATER?
Yes
TOTAL MAXIMUM DAILY LOAD (TMDL) WATERS
n/a
IDENTIFY WETLAND IMPACTS:
1. Will construction result in any potential adverse impacts to wetlands, including excavation,
degradation of water quality, draining, filling, permanent inundation or flooding, conversion to a
stormwater pond?
No.
If yes, describe impacts and mitigation measures that were taken to address the impacts and include
copies of permits or approvals from an official state wide wetland program issued specifically for this
project or site:
N/A
ENVIRONMENTALLY SENSITIVE AREAS:
1. Identify adjacent public waters where the MN DNR has declared "work in water restrictions" during
fish spawning timeframes:
None identified.
2. Describe any stormwater mitigation measures that will be implemented, as a result of an
environmental review, endangered or threatened species review or archeological site review:
N/A
· Project location and construction limits.
· Existing and final grades, including dividing lines and direction of flow for all pre and post-construction
stormwater runoff drainage areas located within the project limits.
(BMP's).
· Buffer zones as required in item 9.17 and 23.11 of the permit.
· Locations of potential pollution-generating activities identified in Section 12 of the permit.
· Standard details for erosion and sediment control BMP's to be installed at the site.
The anticipated erosion prevention and sediment control BMP quantities needed for the life of this project
include the following. These quantities are estimated only and shall be verified by the Contractor.
Bidding Quantity
1 EA
1,775 LF
1 EA
4 EA (size per plan)
0.9 ACRE
1.0 ACRE
4,665 SY
2.
Final Quantity
4.
The Contractor is responsible to salvage and preserve existing topsoil as necessary for final stabilization.
All topsoil to be salvaged and re-used shall be processed as necessary to meet project specifications.
Prior to final seeding, all areas to be vegetated shall be scarified/decompacted and amended as specified
in the plans and specifications.
Unless otherwise noted, all seed mixes and applications shall be in accordance with MNDOT Seeding
Manual, latest edition.
See the project plans and specifications for seed mixtures, mulch, slope stabilization, and all other
landscaping requirements.
1.
2.
3.
Is the project required to install a temporary sediment basin due to 10 or more acres draining to a
common location, or 5 acres or more if the site is located within 1 mile of a special or impaired water?
Yes.
If yes, describe (or attach plans) showing how the basin will be designed and constructed in accordance
with Section 14.
The temporary sedimentation basin will have a minimum storage of 3,600 CF per acre draining to
the basin. The basin outlet will provide for discharging water from the surface to minimize
discharging of pollutants. A stabilized emergency overflow will be provided. See attached plans
for temporary basin locations.
Individuals must receive training from local, state, federal agencies, professional organizations, or other entities
with expertise in erosion prevention, sediment control, permanent stormwater treatment and the MN
NPDES/SDS Construction Stormwater permit. Individuals shall attend a refresher-training course every three (3)
years.
SWPPP IMPLEMENTATION RESPONSIBILITIES:
1.
2.
The Owner and Contractor are Permittee(s) as identified by the NPDES permit.
The Contractor shall be responsible for all on-site implementation of the SWPPP, including all
Subcontractor activities.
3. The Contractor shall provide knowledgeable and experienced person(s) in the application, installation,
and maintenance of Erosion and Sediment Control BMP's throughout the project.
4. The Contractor shall provide person(s) meeting the training requirements of the NPDES permit to conduct
inspection and maintenance of all erosion prevention and sediment control BMP's in accordance with
permit requirements. One of these individuals must be available for an on-site inspection within 72 hours
upon request by the MPCA.
5. The Contractor shall provide training documentation for all individual(s) required by the permit. This
training documentation shall be recorded in the SWPPP prior to construction, or as soon as personnel for
the project have been determined. Documentation shall include:
a. Names of personnel associated with the project required to be trained (as listed above and
under Section 21 of the permit).
b. Dates of training, name of instructor, and entity providing training.
c. Content of training course or workshop including number of hours of training.
INSPECTIONS AND MAINTENANCE:
2.
The Contractor shall provide person(s) meeting the training requirements to conduct inspection and
maintenance of all erosion prevention and sediment control BMP's under this project in accordance with
permit requirements.
An example MPCA construction stormwater checklist can be found at the link below. Note: This template
inspection report does not address all aspects of the NPDES Permit. The completion of this checklist
does not guarantee that all permit requirements are in compliance; it is the responsibility of the
Permittee(s) to read and understand the full permit requirements.
https://www.pca.state.mn.us/sites/default/files/wq-strm2-36.docx
RECORDS RETENTION:
Ensure Final Stabilization of the site. Final Stabilization is not complete until all of the following requirements are
complete:
1. All soil disturbing activities at the site have been completed and soils are stabilized by a uniform perennial
vegetative cover with a density of 70 percent of its expected final growth over the entire pervious surface
area, or other equivalent means necessary to prevent soil erosion under erosive conditions.
2. The permanent stormwater management system is constructed and operating as designed. Temporary or
permanent sedimentation basins that are to be used as permanent water quality management basins
have been cleaned of any accumulated sediment. All sediment has been removed from conveyance
systems and ditches are stabilized with permanent cover.
3. All temporary synthetic and structural erosion prevention and sediment control BMPs (such as silt fence,
bio-logs, etc.) have been removed from the site. BMPs designed to decompose on site may be left in
place.
4. Upon correction of all erosion and sediment items and achieving vegetative cover, temporary erosion
prevention and sediment control BMPs will be removed and properly disposed/recycled.
5. Within 30 days of final stabilization, a notice of termination shall be submitted to the MPCA (see Permit
Termination Req's) .
The SWPPP, including all changes/amendments, and inspections and maintenance records shall be kept on
site during normal working hours by individuals who have operational control of that portion of the site.
1.
2.
The Contractor and all Subcontractors involved with construction activity that disturbs soil, or implements
a pollution control measure as part of the Storm Water Pollution Prevention Plan (SWPPP) for this project,
must comply with the requirements of the National Pollution Discharge Elimination System (NPDES) /
State Disposal System (SDS) Program, General Permit MNR10001, Dated August 1, 2018.
The Contractor and all Subcontractors shall be responsible for reviewing the NPDES Permit in its entirety,
to ensure that all SWPPP measures are in place and permit requirements fulfilled throughout the duration
of the project.
Will the project include dewatering, basin draining?
No.
If yes, describe measures to be used to treat/dispose of turbid or sediment-laden water and method to
prevent erosion or scour of
discharge points (see Section 10 of the permit):
N/A. Based on soil boring results, dewatering is not anticipated.
All Owner(s) shall keep the SWPPP, along with the following additional records, on file for three (3) years after
submittal of the NOT as outlined in Section 4:
a. The Final SWPPP;
b. Any other stormwater related permits required for the project;
c. Records of all inspection and maintenance conducted during construction;
d. All permanent operation and maintenance agreements that have been implemented, including all
Right-Of-Way, Contracts, Covenants, and other binding requirements regarding perpetual maintenance;
and
e. All required calculations for design of the temporary and permanent stormwater management systems.
C 2023 Larson Engineering, Inc. All rights reserved.
(TBD)
NAME, PHONE, EMAIL
FINAL STABILIZATION:
GENERAL SWPPP NOTES:
TEMPORARY SEDIMENT CONTROL (SITE SPECIFIC ITEMS)
CONTRACTOR:
CONTACT:
COURSE, INSTRUCTOR:
TRAINING ENTITY:
EXPIRATION:
This SWPPP was prepared by personnel certified in design of construction SWPPP's as listed above. Copies of
respective certifications are available upon request. In accordance with Section 21 of the permit, the following
individuals must receive training, and the content and extent of the training is commensurate with the individual's
job duties and responsibilities with regard to activities covered under the permit:
a. Individuals preparing the SWPPP for the project.
b. Individuals overseeing implementation of, revising and/or amending the SWPPP, and individuals
performing inspections for the project.
c. Individuals performing or supervising the installation, maintenance and repair of BMP's.
1.
1.
3.
· Soil types at the site.
· Locations of impervious surfaces.
· Locations of areas not to be disturbed (e.g., buffer zones, wetlands, etc.)
· Steep slope locations.
· Locations of areas where construction will be phased to minimize duration of exposed soils.
· Locations of all temporary and permanent erosion control and sediment control best management practices
BMP
Rock Construction Entrance
Sediment Log
Concrete Washout
Outlet Rip-Rap
Turf Seeding
Basin Planting Area
Erosion Blanket
SEEDING NOTES AND REQUIREMENTS:
SWPPP CONTACT:
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
COMPANY (TBD)
ADDRESS
CITY, STATE, ZIP
CONTACT: NAME, PHONE, EMAIL
Attach design parameters for the planned permanent stormwater management system, including volume
calculations, discharge rate calculations, construction details including basin depth, outlet configurations,
location, design of pre-treatment devices, and timing for installation.
See the project plans and stormwater calculations.
COURSE, INSTRUCTOR:
TRAINING ENTITY:
EXPIRATION:
LARSON ENGINEERING, INC.
NATHAN NOHNER, 612-224-6725,
[email protected]
DESIGN OF SWPPP, ONLINE COURSE
UNIVERSITY OF MINNESOTA
MAY 31, 2026
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
CONTRACTOR:
2.
LARSON ENGINEERING, INC.
3524 LABORE ROAD
WHITE BEAR LAKE, MN 55110
CONTACT: BRYAN MILLER, P.E., 651-481-92120,
[email protected]
COMPANY:
CONTACT:
Larson
PROJECT CONTACTS
OWNER:
MARK LAMBERT
SUMMIT MANAGEMENT
6770 STILLWATER BLVD NORTH, SUITE 110
STILLWATER, MN 55082
CONTACT: 651-689-2202
Will the project result in one acre or more of new impervious surface or result in one acre or more of new
impervious in total if the project is part of a larger plan of development?
Yes.
If yes, a water quality volume of one inch of runoff from the cumulative new impervious surfaces must be
retained on site (Section 15) through infiltration unless prohibited due to one of the reasons in item 16.14
through 16.21. If infiltration is prohibited, identify other methods of stormwater treatment used (e.g. filtration,
wet sedimentation basin, regional ponding, or equivalent method):
One (1) new wet sedimentation basin is proposed as part of the project to provide the required
water quality volume from the total new and fully reconstructed impervious areas.
SUMMIT
COMMONS LLC
1.
ST. JOSEPH RV AND
OUTDOOR STORAGE
SWPPP PREPARER:
PROJECT NAME:
ST. JOSEPH RV AND OUTDOOR STORAGE
PROJECT LOCATION: 500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
ENGINEER:
SWPPP TRAINING (SECTION 21):
Client:
PERMANENT STORMWATER MANAGEMENT (SITE SPECIFIC ITEMS)
Project Title:
PROJECT LOCATION AND RECEIVING WATERS MAP:
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
I. GENERAL CONSTRUCTION ACTIVITY INFORMATION
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
Engineering, Inc.
PROJECT SPECIFIC SWPPP INFORMATION:
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
Date: xx.xx.23
Rev.
Lic. No.:
Date
54950
Description
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
Will the project include use of filters for backwash water?
No.
If yes, describe how filter backwash water will be managed on the site or properly disposed of:
N/A
Issue Date:
xx.xx.2023
Sheet Title:
SWPPP
Sheet:
C600
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C600 - SWPPP.dwg
17
3. Stabilize all exposed soil areas (including stockpiles). Stabilization must be initiated immediately to
limit soil erosion whenever any construction activity has permanently or temporarily ceased on any
portion of the site and will not resume for a period exceeding 14 calendar days (or 7 days if within
one mile of an identified impaired water). Stabilization must be completed no later than 14
calendar days (or 7 days if within one mile of an identified impaired water) after the construction
activity has ceased.
4. Stabilization is not required on constructed base components of roads, parking lots, and similar
surfaces. Stabilization is not required on temporary stockpiles without significant silt, clay or
organic components (e.g., clean aggregate stockpiles, demolition concrete stockpiles, sand
stockpiles) but sediment controls must be placed at the base of the stockpile.
5. For Public Waters that the Minnesota Department of Natural Resources has promulgated “work in
water restrictions” during specified fish spawning time frames, all exposed soil areas that are within
200 feet of the water's edge, and drain to these waters must complete the stabilization activities
within 24 hours during the restriction period.
6. Stabilize the normal wetted perimeter of the last 200 linear feet of temporary or permanent
drainage ditches or swales that drain water from the site within 24 hours after connecting to a
surface water or property edge. Stabilize remaining portions of temporary or permanent ditches or
swales within 14 calendar days (or 7 days if within one mile of an identified impaired water) after
connecting to a surface water or property edge and construction in that portion of the ditch
temporarily or permanently ceases.
7. Temporary or permanent ditches or swales being used as sediment containment systems during
construction (with properly designed rock-ditch checks, bio rolls, silt dikes, etc.) do not need to be
stabilized during the temporary period of use as a sediment containment system. These areas
must be stabilized within 24 hours after no longer being used for as a sediment containment
system.
8. Applying mulch, hydromulch, tackifier, polyacrylamide or similar erosion prevention practices is not
acceptable within any portion of the normal wetted perimeter of a temporary or permanent
drainage ditch or swale section with a continuous slope of greater than 2 percent.
9. Pipe outlets must be provided with temporary or permanent energy dissipation within 24 hours
after connection to a surface water or permanent stormwater treatment system.
10.Route water around unstabilized areas on the site and to reduce erosion, unless infeasible. Use
erosion controls and velocity dissipation devices such as check dams, sediment traps, riprap, or
grouted riprap at outlets within and along the length of any constructed stormwater conveyance
channel, and at any outlet, to provide a non‐erosive flow velocity, to minimize erosion of channels
and their embankments, outlets, adjacent stream banks, slopes, and downstream waters during
discharge conditions.
11.Unless infeasible due to lack of pervious or vegetated areas, direct discharges from BMPs to
vegetated areas of the site (including any natural buffers) in order to increase sediment removal
and maximize stormwater infiltration. Use velocity dissipation devices if necessary to prevent
erosion when directing stormwater to vegetated areas.
12.Infiltration areas shall not be excavated until all upstream areas have been stabilized and/or
upstream BMPs are in place to properly prevent sediment deposition. Only low impact equipment
shall be allowed in infiltration areas which shall be clearly identified, staked, and marked/fenced
off.
13.Project phasing shall be implemented to ensure land disturbance and temporary erosion control
measures can be effectively inspected and maintained throughout the duration of the project in
accordance with the Inspection and Maintenance requirements of Section 11.
4. A floating silt curtain placed in the water is not an acceptable sediment control BMP except when
working on a shoreline or below the waterline. Immediately after the short term construction activity
(e.g., installation of rip rap along the shoreline) in that area is complete, upland perimeter control
practices shall be installed if exposed soils still drain to a surface water.
5. Re‐install all sediment control practices that have been adjusted or removed to accommodate
short‐term activities such as clearing or grubbing, or passage of vehicles, immediately after the
short‐term activity has been completed. Complete any short‐term activity that requires removal of
sediment control practices as quickly as possible and re‐install sediment control practices before
the next precipitation event even if the short‐term activity is not complete.
6. All storm drain inlets must be protected by appropriate BMPs during construction until all sources
with potential for discharging to the inlet have been stabilized. Inlet protection may be removed for
a particular inlet if a specific safety concern (street flooding/freezing) has been identified by the
Permittee(s) or the jurisdictional authority (e.g., city/county/township/MnDOT engineer).The
Permittee(s) must document the need for removal in the SWPPP.
7. Temporary soil stockpiles must have silt fence or other effective sediment controls, and cannot be
placed in any natural buffers or surface waters, including stormwater conveyances such as curb
and gutter systems, or conduits and ditches unless there is a bypass in place for the stormwater.
a. All perimeter control devices must be repaired, replaced, or supplemented when they become
nonfunctional or the sediment reaches one‐half (1/2) of the height of the device. These repairs must
be made by the end of the next business day after discovery, or thereafter as soon as field conditions
allow access.
b. Temporary and permanent sedimentation basins must be drained and the sediment removed when
the depth of sediment collected in the basin reaches one‐half (1/2) the storage volume. Drainage and
removal must be completed within 72 hours of discovery, or as soon as field conditions allow access.
c. Surface waters, including drainage ditches and conveyance systems, must be inspected for evidence
of erosion and sediment deposition during each inspection. Remove all deltas and sediment
deposited in surface waters, including drainage ways, catch basins, and other drainage systems, and
restabilize the areas where sediment removal results in exposed soil. The removal and stabilization
must take place within seven (7) days of discovery unless precluded by legal, regulatory, or physical
access constraints. Use all reasonable efforts to obtain access. If precluded, removal and stabilization
must take place within seven (7) calendar days of obtaining access. Contact all local, regional, state
and federal authorities and receiving any applicable permits, prior to conducting any work in surface
waters.
d. Construction site vehicle exit locations must be inspected for evidence of off ‐site sediment tracking
onto paved surfaces. Tracked sediment must be removed from all paved surfaces both on and off site
within 24 hours of discovery, or if applicable, within a shorter time.
e. Streets and other areas adjacent to the project must be inspected for evidence of off ‐site
accumulations of sediment. If sediment is present, it must be removed in a manner and at a frequency
sufficient to minimize off ‐site impacts (e.g., fugitive sediment in streets could be washed into storm
sewers by the next rain and/or pose a safety hazard to users of public streets).
4. Permittees may terminate coverage upon MPCA approval after submitting information
documenting the owner canceled the project.
5. Permittees must complete all construction activity and must install permanent cover over all areas
prior to submitting the NOT. Vegetative cover must consist of a uniform perennial vegetation with a
density of 70 percent of its expected final growth. Vegetation is not required where the function of a
specific area dictates no vegetation, such as impervious surfaces or the base of a sand filter.
6. Permittees must clean the permanent stormwater system of any accumulated sediment and must
ensure the system meets all applicable requirements in Section 15 through 19 of the permit and is
operating as designed.
7. Permittees must remove all sediment from conveyance systems prior to submitting the NOT.
8. Where vehicle traffic leaves any part of the site (or onto paved roads within the site) install a
vehicle tracking BMP to minimize the track out of sediment from the construction site. Examples of
vehicle tracking BMPs include (but are not limited to) rock pads, mud mats, slash mulch, concrete
or steel wash racks, or equivalent systems. Use street sweeping if such vehicle tracking BMPs are
not adequate to prevent sediment from being tracked onto the street.
9. The Permittee(s) must install temporary sedimentation basins as required in accordance with
permit requirements.
10.Minimize soil compaction by restricting vehicle access in areas where final vegetative stabilization
will occur, unless otherwise infeasible.
11.Discharges from BMPs shall be directed to vegetated areas unless infeasible.
12.Preserve a 50 foot natural buffer or (if a buffer is infeasible on the site) provide redundant (double)
perimeter sediment controls when a surface water is located within 50 feet of the project's earth
disturbances and stormwater flows to the surface water.
13.Perimeter sediment controls shall be installed at least 5 feet apart unless limited by lack of
available space. Natural buffers are not required adjacent to road ditches, judicial ditches, county
ditches, stormwater conveyance channels, storm drain inlets, and sediment basins. If preserving
the buffer is infeasible, the reasons for which shall be recorded in the SWPPP.
14. The use of polymers, flocculants, or other sedimentation treatment chemicals, if used on the
project, shall be used in accordance with accepted engineering practices, dosing specifications,
and sediment removal design specifications provided by the product manufacturer or supplier. Use
conventional erosion and sediment controls prior to the chemical addition to ensure effective
treatment. Chemicals may only be applied where treated stormwater is directed to a sediment
control system which allows or filtration of settlement of the floc prior to discharge.
15.If the proposed project as shown on the plans has 10 or more acres draining to a common location
or 5 acres or more if the site is within one mile of a special or impaired water (as identified in
Section II - Receiving Waters and Environmentally Sensitive Areas), then a temporary sediment
basin must be constructed as shown on the plans. Temporary sediment basins will have a
minimum of 3,600 cubic feet of storage per acre draining to the basin. The basin outlet shall
provide for discharging water from the surface to minimize discharging of pollutants. A stabilized
emergency overflow shall be constructed.
DEWATERING AND BASIN DRAINING (SECTION 10)
1. Discharge turbid or sediment‐laden waters related to dewatering or basin draining (e.g., pumped
discharges, trench/ditch cuts for drainage) to a temporary or permanent sediment basin on the
project site unless infeasible. Discharge from the temporary or permanent sedimentation basins to
surface waters if the basin water has been visually checked to ensure adequate treatment has
been obtained in the basin and that nuisance conditions will not result from the discharge. If the
water cannot be discharged to a sedimentation basin prior to entering the surface water, it must be
treated with the appropriate BMPs, such that the discharge does not adversely affect the receiving
water or downstream properties.
2. Discharge water that contains oil or grease, must use an oil‐water separator or suitable filtration
device (e.g. cartridge filters, absorbents pads) prior to discharging the water.
3. All water from dewatering or basin‐draining activities must be discharged in a manner that does
not cause nuisance conditions, erosion in receiving channels or downslope properties, erosion or
scour in the immediate vicinity of discharge points, or inundation in wetlands causing significant
adverse impact to the wetland.
4. The use of filters with backwash water, haul the backwash water away for disposal, return the
backwash water to the beginning of the treatment process, or incorporate the backwash water into
the site in a manner that does not cause erosion. Discharge backwash water to the sanitary sewer
if permission is granted by the sanitary sewer authority. Replace and clean the filter media used in
dewatering devices when required to retain adequate function.
5. Inspection frequency adjustment:
a. Inspections of areas with permanent cover can be reduced to once per month, even if construction
activity continues on other portions of the site; or
b. where sites have permanent cover on all exposed soil and no construction activity is occurring
anywhere on the site, inspections can be reduced to once per month and, after 12 months, may be
suspended completely until construction activity resumes. The MPCA may require inspections to
resume if conditions warrant; or
c. where construction activity has been suspended due to frozen ground conditions, inspections may be
suspended. Inspections must resume within 24 hours of runoff occurring, or upon resuming
construction, whichever comes first.
3. All inspections and maintenance activities within 24 hours of being conducted must be recorded and
retained in the SWPPP. These records must include:
a. Date and time of inspections
b. Name of person(s) conducting inspections
c. Findings of inspections, including the specific location where corrective actions are needed
d. Corrective actions taken (including dates, times, and party completing maintenance activities)
e. Date and amount of all rainfall events greater than 1/2 inch (0.5 inches) in 24 hours. Rainfall amounts
must be obtained by a properly maintained rain gauge installed onsite, a weather station that is within
1 mile of your location or a weather reporting system that provides site specific rainfall data from radar
summaries.
f. If any discharge is observed to be occurring during the inspection, a record of all points of the property
from which there is a discharge must be made, and the discharge should be described (i.e., color,
odor, floating, settled, or suspended solids, foam, oil sheen, and other obvious indicators of pollutants)
and photographed.
g. Any amendments to the SWPPP proposed as a result of the inspection must be documented within
seven (7) calendar days.
4. All infiltration areas must be inspected to ensure that no sediment from ongoing construction activity is
reaching the infiltration area. All infiltration areas must be inspected to ensure that equipment is not being
driven across the infiltration area.
POLLUTION PREVENTION MANAGEMENT MEASURES (SECTION 12)
Implement the following pollution prevention management measures on the site:
1. Storage, Handling, and Disposal of Construction Products, Materials, and Wastes shall comply with the
following to minimize the exposure to stormwater of any of the products, materials, or wastes. Products
or wastes which are either not a source of contamination to stormwater or are designed to be exposed to
stormwater are not held to this requirement:
a. Building products that have the potential to leach pollutants must be under cover (e.g., plastic
sheeting or temporary roofs) to prevent the discharge of pollutants or protected by a similarly effective
means designed to minimize contact with stormwater.
b. Pesticides, herbicides, insecticides, fertilizers, treatment chemicals, and landscape materials must be
under cover (e.g., plastic sheeting or temporary roofs) to prevent the discharge of pollutants or
protected by similarly effective means designed to minimize contact with stormwater.
c. Hazardous materials, toxic waste, (including oil, diesel fuel, gasoline, hydraulic fluids, paint solvents,
petroleum‐based products, wood preservatives, additives, curing compounds, and acids) must be
properly stored in sealed containers to prevent spills, leaks or other discharge. Restricted access
storage areas must be provided to prevent vandalism. Storage and disposal of hazardous waste or
hazardous materials must be in compliance with Minn. R. ch. 7045 including secondary containment
as applicable.
d. Solid waste must be stored, collected and disposed of properly in compliance with Minn. R. ch. 7035.
e. Portable toilets must be positioned so that they are secure and will not be tipped or knocked over.
Sanitary waste must be disposed of properly in accordance with Minn. R. ch. 7041.
2. Fueling and Maintenance of Equipment or Vehicles; Spill Prevention and Response: Take reasonable
steps to prevent the discharge of spilled or leaked chemicals, including fuel, from any area where
chemicals or fuel will be loaded or unloaded including the use of drip pans or absorbents unless
infeasible. Conduct fueling in a contained area unless infeasible. Ensure adequate supplies are available
at all times to clean up discharged materials and that an appropriate disposal method is available for
recovered spilled materials. Report and clean up spills immediately as required by Minn. Stat. § 115.061,
using dry clean up measures where possible.
8. Permittees must remove all temporary synthetic erosion prevention and sediment control BMPs
prior to submitting the NOT. BMPs designed to decompose on-site may be left in place.
9. For residential construction only, permit coverage terminates on individual lots if the structures are
finished and temporary erosion prevention and downgradient perimeter control is complete, the
residence sells to the homeowner, and the permittee distributes the MPCA's "Homeowner Fact
Sheet" to the homeowner.
10.For construction projects on agricultural land (e.g., pipelines across cropland), disturbed land must
be returned to its preconstruction agricultural condition prior to submitting the NOT.
11. When submitting the NOT, permittees must include either ground or aerial photographs showing
vegetative cover requirements have been met as listed above. All submitted photographs shall
include the date and specific site location.
LONG TERM OPERATION AND MAINTENANCE:
1. Upon the completion of construction activity and NPDES permit termination, in accordance with
Sections 4 and 13, the Property Owner shall become the responsible party for long term operation
and maintenance (O&M) of all permanent stormwater management features under this project.
2. All associated operations, inspections, maintenance, and record keeping shall be performed by
trained individual(s) familiar with the site stormwater management system.
3. Record keeping of inspections and maintenance items shall be maintained by the Owner in
accordance with applicable Maintenance Agreements/Declarations as required by local
jurisdictional authorities.
I hereby certify that this plan,
specifications or report was prepared
by me or under my direct supervision
and that I am a duly licensed
Professional Engineer under the laws
of the state of Minnesota.
Bryan D. Miller, P.E.
Date: xx.xx.23
Rev.
4. Concrete and other washouts waste: Provide effective containment for all liquid and solid wastes
generated by washout operations (concrete, stucco, paint, form release oils, curing compounds and other
construction materials) related to the construction activity. The liquid and solid washout wastes must not
contact the ground, and the containment must be designed so that it does not result in runoff from the
washout operations or areas. Liquid and solid wastes must be disposed of properly and in compliance
with MPCA rules. A sign must be installed adjacent to each washout facility that requires site personnel
to utilize the proper facilities for disposal of concrete and other washout wastes.
P:\Projects\Projects - 2023\12236025 - St. Joseph Outdoor Storage\C. Design\Drawing Files\12236025 - C600 - SWPPP.dwg
18
Lic. No.:
Date
54950
Description
Project #:
12236025.000
Drawn By:
NJN
Checked By: BDM
Issue Date:
3. Vehicle and equipment washing: Wash the exterior of vehicles or equipment on the project site, washing
must be limited to a defined area of the site. Runoff from the washing area must be contained in a
sediment basin or other similarly effective controls and waste from the washing activity must be properly
disposed of. Properly use and store soaps, detergents, or solvents. No engine degreasing is allowed on
site.
3524 Labore Road
White Bear Lake, MN 55110
651.481.9120 (f) 651.481.9201
www.larsonengr.com
Larson
After permit coverage is terminated under this item, any subsequent development on the remaining
portions of the site will require permit coverage if the subsequent development itself or as part of
the remaining common plan of development or sale will result in land disturbing activity of one (1)
or more acres in size.
C 2023 Larson Engineering, Inc. All rights reserved.
3. Temporary or permanent drainage ditches and sediment basins designed as part of a sediment
containment system (e.g., ditches with rock-check dams) require sediment control practices only
as appropriate for site conditions.
3. Permittees may terminate permit coverage prior to completion of all construction activity if they
meet all of the following conditions:
a. Construction activity has ceased for at least 90 days; and
b. at least 90 percent (by area) of all originally proposed construction activity has been completed
and permanent cover has been established on those areas; and
c. on areas where construction activity is not complete, permanent cover has been established;
and
d. the site complies with items 13.3 through 13.7 of the permit.
6770 STILLWATER BLVD N, SUITE 110
STILLWATER, MN 55082
2. Minimize the need for disturbance of portions of the project with steep slopes. For those sloped
areas which must be disturbed, use techniques such as phasing and stabilization practices
designed for steep slopes (e.g., slope draining and terracing).
2. Inspect all erosion prevention and sediment control BMPs and Pollution Prevention Management
Measures to ensure integrity and effectiveness during all routine and post‐rainfall event inspections. All
nonfunctional BMPs must be repaired, replaced, or supplemented with functional BMPs by the end of the
next business day after discovery, or as soon as field conditions allow access unless another time frame
is specified below. Investigate and comply with the following Inspection and Maintenance requirements:
2. Permittees must submit a NOT within 30 days after selling or otherwise legally transferring the
entire site, including permit responsibility for roads (e.g., street sweeping) and stormwater
infrastructure final clean out, or transferring portions of a site to another party. The permittees'
coverage under the permit terminates at midnight on the submission date of the NOT.
500 CEDAR STREET WEST
ST. JOSEPH, MN 56374
1. Prior to beginning any construction work at the site, locations of areas not to be disturbed must be
delineated (e.g., with flags, stakes, signs, silt fence, snow fence, etc.) throughout the project site.
2. If downgradient sediment controls become overloaded, based on frequent failure or excessive
maintenance requirements, additional upgradient sediment control practices or redundant BMPs
shall be installed to eliminate the overloading concerns. All changes shall be recorded in the
SWPPP.
1. Permittees must submit a NOT within 30 days after all termination conditions listed in Section 13
are complete.
SUMMIT
COMMONS LLC
TEMPORARY EROSION PREVENTION PRACTICES (SECTION 8)
1. Owner and Contractor shall ensure that a trained person (as identified in item 21.2.b) of the permit will
inspect the entire construction site at a minimum:
- Once every seven (7) days during active construction, and
- Within 24 hours after a rainfall event greater than 1/2 inch in 24 hours
ST. JOSEPH RV AND
OUTDOOR STORAGE
1. All BMPs identified in the SWPPP document and construction plans shall be selected, installed,
and maintained in an appropriate and functional manner in accordance with relevant manufacturer
specifications and accepted engineering practices.
1. Sediment control practices must be established on all down gradient perimeters and be located
upgradient of any buffer zones. The perimeter sediment control practices must be in place before
any upgradient land‐disturbing activities begin. These practices shall remain in place until Final
Stabilization has been established.
PERMIT TERMINATION (SECTIONS 4 AND 13)
Client:
BMP SELECTION AND INSTALLATION (SECTION 7):
INSPECTIONS AND MAINTENANCE (SECTION 11)
Project Title:
1. One of the individuals described in item 21.2.a or 21.2.b of the permit or another qualified
individual must complete all SWPPP changes. Changes involving the use of less stringent BMPs
must include a justification describing how the replacement BMP is effective for the site
characteristics.
2. The SWPPP shall be amended to include additional or modified BMPs as necessary to correct
problems identified or address situations whenever there is a change in design, construction,
operation, maintenance, weather or seasonal conditions having a significant effect on the
discharge of pollutants to surface waters or groundwater.
3. The SWPPP shall be amended to include additional or modified BMPs as necessary to correct
problems identified or address situations whenever inspections or investigations by the site owner
or operator, USEPA or MPCA officials indicate the SWPPP is not effective in eliminating or
significnatly minimizing the ischarge of pollutants to surface waters or groundwater or the
discharges are cuasing water quality standard exceedances (e.g., nuisance conditions as defined
in Minn. R. 7050.0210, subp. 2 or the SWPPP is not consistend with the ofjectives of the USEPA
approved TMDL.
TEMPORARY SEDIMENT CONTROL PRACTICES (SECTION 9)
2023.11.01 CITY SUBMITTAL - NOT FOR CONSTRUCTION
SWPPP AMENDMENTS (SECTION 6):
Engineering, Inc.
GENERAL SWPPP REQUIREMENTS AND NOTES:
xx.xx.2023
Sheet Title:
SWPPP
Sheet:
C601
The government’s own published record — read it yourself, then decide what to do about it.
The facilities, the coverage, and the local record for this community.
Not yet recorded. The record stays open — outcomes are added as minutes and vote results are published.
Provenance
Where this record came from. Every source is listed, permanently.
- Agenda Watch · Aug 16, 2026
Permanent ID DKT-2026-000837 — this record is never deleted.
Record history
Every change to this record, logged as it happened.
- Aug 16, 2026 Filed on the Docket
- Aug 16, 2026 Full document archived — public record
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 27, 2026 Record updated
- Aug 28, 2026 Record updated
← The full Docket · every meeting, vote, and action on the permanent record · also in the National Record Index.