⚡︎ Independent, reader-supported & ad-free · Follow the megawatts in all 50 states ⚡︎ Support Us
The Docket · Government Meeting · DKT-2026-000380

On the agenda: Front Royal meeting — Data Center (May 11)

Past  ⚠ Agenda Watch  Front Royal, Virginia · Monday, May 11, 2026 — 6 months ago

About this record

The published agenda for the May 11, 2026 meeting contains: "Data Center", "data center", "DATA CENTER". The meeting has passed. The agenda stays here as a permanent public record.

WhenMonday, May 11, 2026
Check the agenda document for the meeting time.
WhereFront Royal, Virginia
Money$127,722.00 was at stake
On the record“Data Center”“data center”“DATA CENTER”

The agenda, word for word

Government public record — the full text of the published document, archived August 4, 2026. Gold highlighting of key terms is ours, not the original’s. Read the original document ↗

75 pages · scroll to read
Page 1 of 75

TOWN COUNCIL REGULAR WORK SESSION
Monday, May 11 @ 7:00 PM
Town Hall Conference Room
View meeting online LIVE at https://www.frontroyalva.com/673/Town-Hall-Live

1. Roll Call
2. PUBLIC HEARING
a. FY 26-27 Proposed Annual Appropriation Ordinance
3. PRESENTATION on Alternative Water Source Options
4. NEW BUSINESS
a. Water Tank Maintenance Service Program- M. Campbell
b. Purchase of Replacement Bucket Truck for Department of Energy- M Campbell
5. UNFINISHED BUSINESS
a. Zoning Text Amendments to Town Code §175-3-Definitions, to define Data Centers and
Town Code §175-64 – Statement of Intent Industrial Employment District (I-2) to add Data
Centers with Performance Standards by Special Use Permit
6. CLOSED MEETING
7. ADJOURN

Page 2 of 75

REGULAR COUNCIL MEETING
AGENDA STATEMENT

Meeting Date: May 11, 2026

Item# 2A

Agenda Item: PUBLIC HEARING – Receive Public Comment on the Proposed Annual Appropriation Ordinance (Budget)
for Fiscal Year 2026-2027
Summary: Council is requested to receive public comment on the Town’s proposed annual appropriation ordinance
(Budget) for fiscal year 2026-2027
The Council will vote to adopt the proposed FY26-27 appropriation ordinance at the May26th Meeting
Budget/Funding: None
Meetings: Work Sessions held April 6 and April 13,2026

Proposed Motion: No action is required

Moved ____________________ Seconded ____________________
Wood __________ Veitenthal __________ Sealock __________ Rappaport __________ Ingram __________ DeDomenico-Payne __________

Page 3 of 75

ANNUAL APPROPRIATION ORDINANCE OF THE TOWN OF FRONT ROYAL, VIRGINIA FOR THE
FISCAL YEAR ENDING JUNE 30, 2027 TO MAKE APPROPRIATIONS OF SUMS OF MONEY FOR ALL
NECESSARY EXPENDITURES, TO PRESCRIBE THE PROVISOS, TERMS, CONDITIONS, AND
PROVISIONS WITH RESPECT TO THE TERMS OF APPROPRIATION AND THEIR PAYMENTS, AND TO
REPEAL ALL ORDINANCES WHOLLY IN CONFLICT WITH THIS ORDINANCE AND ALL PARTS OF
ALL ORDINANCES INCONSISTENT WITH THIS ORDINANCE TO THE EXTENT OF SUCH
INCONSISTENCY.
WHEREAS, under §15.2-2503 of the Code of Virginia, and pursuant to The Code of the Town of Front Royal, Virginia,
the Town of Front Royal (the “Town”) must adopt a budget for fiscal year 2026-2027 before July 1, 2026; and,
WHEREAS, on _____________________2026, the Town Council of the Town (the “Council”) conducted a public
hearing for citizen comment on the proposed budget after publication of a budget synopsis in accordance with §15.2-2506
of the Code of Virginia; and,
WHEREAS, at least seven days have elapsed since that public hearing; and,
WHEREAS, the Council is of the opinion that the proposed budget should be adopted; and,
NOW, THEREFORE, be it ordained by the Council of the Town of Front Royal, Virginia that the following sums of
money are hereby appropriated for the general government purposes herein specified for the fiscal year ending June 30,
2027.

DRAFT
GENERAL FUND EXPENDITURES

General Government
Financial Administration
Legal
Law Enforcement Services
General Property Maintenance
Planning & Zoning
Community Development/Special Events/Tourism
Risk Management/Insurance
Economic Development
Information Technology
Transfers/Debt Services/Contingency Reserve
TOTAL GENERAL FUND EXPENDITURES

554,615
1,601,020
488,760
6,655,980
1,748,575
777,665
497,445
1,266,105
68,070
697,985
1,125,810
15,482,030

STREET FUND EXPENDITURES
Public Works
State Highway Maintenance System
TOTAL STREET FUND EXPENDITURES

679,660
2,900,000
3,579,660

SPECIAL REVENUE FUND
Community Development/Special Projects
Asset Forfeiture
TOTAL SPECIAL REVENUE FUND EXPENDITURES

458,370
12,000
470,370

and the following sums of money are hereby appropriated for the enterprise operations specified for the year ending June 30, 2027.

Page 4 of 75

ELECTRIC FUND EXPENDITURES
Operations
Purchase of Bulk Electricity
Transfer to General Fund
TOTAL ELECTRIC FUND EXPENDITURES

3,293,950
17,638,790
2,234,000
23,166,740

WATER FUND EXPENDITURES
Administrative Office
Water Plant Operations
Maintenance of Lines
Meter Reading
Debt Service
Contingency & Transfers to Other Funds
TOTAL WATER FUND EXPENDITURES

215,455
2,578,565
1,769,055
130,115
963,005
600,000
6,256,195

SEWER FUND EXPENDITURES

Administrative Office
Wastewater Treatment Plant Operations
Maintenance of Lines
Debt Service
Contingency and Transfers to Other Funds
TOTAL SEWER FUND EXPENDITURES

DRAFT
REFUSE FUND EXPENDITURES

215,425
3,223,100
1,047,555
1,968,880
1,185,000
7,639,960

Operations
Contingency and Transfer to General Fund
TOTAL REFUSE FUND EXPENDITURES

1,737,155
190,000
1,927,155

TOTAL ALL FUNDS EXPENDITURES

58,522,110

Page 5 of 75

REVENUES TO BE PROVIDED AS FOLLOWS
GENERAL FUND
Real Estate Property Tax
Public Service Property Tax & Tax Penalties
Personal Property Tax
Other Local Taxes
Permits and Fees
Fines and Forfeitures
Revenue from Use of Money and Property
Public Rights-of-Way Use Fee
Intergovernmental
Interfund Transfers:
Electric Fund
Water Fund
Sewer Fund
Refuse Fund
Miscellaneous Receipts
TOTAL GENERAL FUND REVENUE

DRAFT

State Highway Maintenance Funds
Revenue from Use of Money and Property
Transfers from General Fund
TOTAL STREET FUND REVENUE

STREET FUND

SPECIAL REVENUE FUND
Asset Forfeiture Grant Funding
Community Development
TOTAL SPECIAL REVENUE FUND
ELECTRIC FUND
Revenue from Use of Money & Property
Connection Fees
Sale of Service
Miscellaneous Receipts
TOTAL ELECTRIC FUND REVENUE

1,680,080
73,850
851,470
8,069,730
79,400
195,925
238,660
2,430
697,840
2,060,000
600,000
700,000
190,000
42,645
15,482,030
2,892,290
115,760
571,610
3,579,660
12,000
458,370
470,370

406,165
239,600
22,488,825
32,150
23,166,740

Page 6 of 75

WATER FUND
Revenue from Use of Money and Property
Antenna Rentals
Sale of Service and Commodities
System Development Connection Fees
Miscellaneous Receipts
TOTAL WATER FUND REVENUE

267,665
89,685
5,713,265
167,580
18,000
6,256,195

SEWER FUND
Revenue from Use of Money and Property
Sale of Services and Commodities
System Development Fees/Connection Fees
Miscellaneous Receipts
TOTAL SEWER FUND REVENUE

267,665
6,903,935
317,860
150,500
7,639,960

REFUSE FUND
Revenue from Use of Money and Property
Sale of Services/Bags/Other
TOTAL REFUSE FUND REVENUE

115,635
1,811,520
1,927,155

TOTAL ALL FUNDS REVENUES

58,522,110

DRAFT

This ordinance shall become effective July 1, 2026.

APPROVED:

_____________________
Lori A. Cockrell, Mayor

ATTEST:
____________________________

Hillary Wilfong, Deputy Clerk of Council
This Ordinance was adopted at the Regular Meeting of the Town of Front Royal, Virginia Town Council conducted
on __________________________, 2026 upon the following recorded vote:
R. Wayne Sealock

__Yes __No

H. Bruce Rappaport

__Yes __No

Joshua L. Ingram

__Yes __No

Melissa DeDomenico-Payne

__Yes __No

Amber F. Veitenthal

__Yes __No

Glenn E. Wood

__Yes __No

A public hearing on the above was held on ______________________having been advertised in the Northern
Virginia Daily on April 29 and May 4, 2026.
*********************************************************************
Approved as to Form and Legality:
________________________________
George M. Sonnett, Jr., Town Attorney

Dated: __________________________

Page 7 of 75

COUNCIL REGULAR WORK SESSION
AGENDA STATEMENT
Meeting Date: May 11, 2026

Item# 3

Agenda Item: Presentation on Alternative Water Source Options

Summary: In February 2025, the Town’s environmental engineering firm, C.H.A. Consulting, provided Town
Council with an update regarding alternative water source options the Town may want to consider. CHA will
present recent findings regarding options for a potential alternative water source option.

Budget/Funding: N/A

Staff Recommendation: Staff recommends for Council to discuss any questions/concerns regarding options for
an alternative water source and provide staff with direction if Council would like to obtain estimates for
continuing with next steps.

Page 8 of 75

Town of Front Royal
Quarry Water Source Evaluation

Page 9 of 75

Alternative Sources
Quarry
• Site Characteristics
– Proximity to Distribution System
– Site Access

• Source Characteristics
– Sampling
– Yield

• Withdrawal Option Evaluation
– Option 1: Pump to Existing WTP
– Option 2: Onsite Treatment

2

Page 10 of 75

Alternative Sources
Quarry

• Proximity to Existing System
– less than 1,000 feet from existing
transmission main.

• Site Access
– Abandoned quarry roads provide
access to proposed site from Depot
Ave.

3

Page 11 of 75

Alternative Sources
Quarry
Constituent

Measured Value

MCL / SMCL Limit

Barium

26.9 µg/L

2 mg/L

Chloride

37.3 mg/L

250 mg/L (SMCL)

Fluoride

0.10 mg/L (estimated)

4 mg/L

Sulfate

45.2 mg/L

250 mg/L (SMCL)

Nitrate

0.14 mg/L

10 mg/L

Atrazine

0.016 µg/L (estimated)

0.003 mg/L

Gross Beta

0.823 ± 0.602 (1.22) pCi/L

4 mrem/year (~50 pCi/L)

Radium-226

0.000 ± 0.027 (0.490) pCi/L Included in Total Radium

Radium-228

0.622 ± 0.390 (0.765) pCi/L Included in Total Radium

Uranium-238

0.577 ± 0.250 (0.072) pCi/L

30 µg/L (~20.1 pCi/L)

Total Radium

0.622 ± 0.597 (1.26) pCi/L

5 pCi/L

• Sampling
– One sample was taken from surface
water near proposed site.
– No results of initial sampling disqualify
the quarry as a viable source.

• Assumed Yield
– Conservative yield of 1.0 MGD, based
on average pumping rate in active
quarry on opposite side of river.

4

Page 12 of 75

Options to Incorporate Quarry Water into Distribution
System
Option 1: Pump to Existing WTP

Option 2: Onsite Treatment

•

Minimal infrastructure required

•

~2,000LF of water main required

•

~20,000LF of water main required

•

Discharges directly into distribution system

•

2 Railroad crossings

•

Minimal easements/land acquisition required

•

1 Stream crossing

•

Multiple structures for treatment facility and

•

Permitting and easement costs

booster station

5

Page 13 of 75

Questions?

6

Page 14 of 75

COUNCIL REGULAR WORK SESSION
AGENDA STATEMENT

Meeting Date:

May 11, 2026

Item#

4A

Agenda Item:

Water Tank Maintenance Service Program

Summary:

Council is requested to award a contract to Southern Corrosion, Inc., of Roanoke Rapids,
NC, to provide annual inspections, washouts, renovations, and repairs for the Towns
four water tanks, in the amount of $127,722.00.
The water tanks to be serviced are:
•
•
•
•

1,000,000 Gallon Route 522 Hydropillar Water Tank
3,000,000 Gallon Guard Hill Ground Storage Water Tank
3,000,000 Gallon Route 55 Ground Storage Water Tank
100,000 Gallon 4H Ground Storage Water Tank

The Town will be using cooperative contracting utilizing the Town of Wytheville, Va.
2025-04 RFP Professional Tank Maintenance Services Contract, as the method of
procurement.

Budget/Funding:

Funding is available under the following line item:
9601-43005 Water Plant – Maintenance Service Contracts

Staff Recommendation:

Staff recommends for Town Council to award as presented.

$127,722.00

Page 15 of 75

Engineered Tank Care Proposal
for the Town of Front Royal,
Virginia
May 4, 2026

Page 16 of 75

THE SOUTHERN CORROSION

Story

Southern Corrosion, Inc. was founded in 1983 with a new vision for the care and maintenance of water
tanks…a vision founded in the principles of engineering, superior workmanship, and outstanding
customer service.
We create customized tank maintenance programs that provide better asset management, better cash
flow, and better value for tank owners throughout the Mid-Atlantic and Southeast.

ENGINEERED TANK CARE™
Our programs are designed and approved by on-staff engineers. We focus on tank life and appearance,
water quality, and a level of care and attention to detail that is unequaled in our industry. When a tank
enters our Engineered Tank Care program, we are fully vested in the life and future of that tank. It’s all
about maximizing water tank life, keeping tanks looking their absolute best, and making tank management
cost-effective, simple, and worry-free.

DEPENDABLE, EXPERT TANK CARE
From the initial inspection through the creation and
implementation of each custom program, our customers
have come to expect superior service and consistent results.
We have our own, dedicated crews strategically located
throughout our regions and sales representatives that live
in the areas they service. We’re proud to call our customers
friends and neighbors.
You’ll know exactly what your tank maintenance is going
to cost, when maintenance will be performed, and why it
is needed. We work with our customers to make sure that
every aspect of their plans fit with their needs and budgets.
No surprises. No hidden costs. We take pride in every tank
in our program.
Our Engineered Tank Care services include:
• Painting, Restoration, and Repair
• Inspections and Washouts
• Engineered Tank Care™ Maintenance Plans
• Elite Inspections & Maintenance
• Cell Antenna Engineering Analysis

2

Page 17 of 75

SOUTHERN CORROSION

Key Staff

JIM SKILTON, President
Jim has been climbing water towers since he was 15 years old, working for his dad
Harry Skilton’s company in New Jersey. Essentially, Jim has been climbing water
towers before he could drive! Jim joined Southern Corrosion in 1985 and became
President in 1989. In 2006, Jim’s Dad retired and sold Southern Corrosion to Jim
and his former business partner’s son Elbert Basolis. Jim believes in treating our
customers like family. We are dedicated to communicating and coordinating with
our customers in every interaction. Jim graduated from the University of Delaware
with a BS in Business Administration and a MBA from Campbell University. Jim
teaches Engineered Tank Care™ seminars and continuing education classes. When
Jim is not working, you can find him traveling, shooting sporting clays, going to the
horse races and enjoying Lake Life!
ELBERT BASOLIS, Co-Owner
Elbert Basolis is an expert in temporary water tank solutions and co-owner of
Southern Corrosion. He is also CEO of Garrison Enterprises, a mechanical contracting
company serving the water industry, an owner or active participant in at least six
other complementary industrial businesses, and the Co-Chairman of the Board of
Yardville National Bank, NA, which was recently purchased by PNC bank. Elbert
splits his time between his home in New Jersey and his North Carolina based offices.
ED SOLTIS, Operations Manager

Since 1984, Ed has been working on water towers. Ed Soltis is a certified NACE Level
1 coatings inspector and a SSPC C3 Supervisor for Deleading Industrial Structures.
He specializes in surface preparation, water tower painting and minor repairs. He
has been Southern Corrosion’s Manager of Operations since 2008.

RYAN LUCY, Area Representative
Ryan, a graduate of Hampden-Sydney College joined the Southern Corrosion family in
2016 as a coatings inspector. He brings more than a decade of experience in business
development and customer service to the team, proudly serving clients in the MidAtlantic and Northern territories for the company Ryan is an AMPP credentialed
Level 2 Certified Coatings Inspector and a certified trainer in Engineered Tank Care™
water tank maintenance.

3

Page 18 of 75

TOM DELBRIDGE, Area Representative

For over 40 years, Tom has worked in Public Utilities. He also has been the Superintendent
of a Class 2 Water Treatment Plant in the State of Virginia for the past 32 years. Tom
has a Virginia Class 1 Water Works License and a Backflow Prevention Device Worker
License issued by DPOR. He has served on the Virginia Rural Water Association
Board of Director since 1995. He is currently representing the State of Virginia as its
National Director for National Rural Water Association and serves on the Executive
committee for National Rural Water.

KENNY KEEL, Engineer
Kenny has over 32 years of experience in management, O&M, design, and improvement
of water and wastewater systems. From 1999 to 2017 he was the Town Engineer/
Utilities Director for the Town of Hillsborough, followed by 5 years as Utilities Director
in Pender County, and he completed his government service with Harnett Regional
Water in 2025. He also spent 7 years in private consulting, designing and managing
a wide variety of water and wastewater projects. Kenny is a licensed Professional
Engineer in NC, licensed building contractor, and holds multiple certifications in water
and wastewater operations. He holds a Bachelor of Science in Civil Engineering from
NC State University, was on the Board of Directors of the NC Rural Water Association
for 10 years and is a Fellow of the Professional Engineers of NC.
DANIEL WILSON, Engineer
Daniel has over 25 years of experience in the water and wastewater industry.
A Professional Engineer licensed in 13 states, he previously served as CEO and
Executive Director of the NC Rural Water Association from 2007 to 2021. Prior to that
he has worked in local government utilities and as a consultant. Daniel is a certified
AMPP/NACE level 2 coating inspector and a Certified Association Executive and holds
advanced level certifications in water and wastewater operations. He also holds a
Bachelor of Science in Civil Engineering from UNC Charlotte and a Masters in Business
Administration from East Carolina University. Along with his work with customers
in eastern South Carolina, he also presents regularly at industry conferences and
training events on a variety of technical, managerial and financial topics.

738 Thelma Road
Roanoke Rapids, NC 27870
P: 800-828-0876 | F: 252-535-3215
[email protected]
TANKCARE.NET
4

Page 19 of 75

SOUTHERN CORROSION

Testimonials

“As a small utility, we are constantly looking for ways to cut costs without compromising compliance or
the services we offer our customers…Southern Corrosion demonstrated exceptional customer service,
responded quickly, scheduled the repairs at a time convenient to us and delivered on their promise. We
are excited about the opportunity to work with Southern Corrosion and hope the relationship lasts for
years to come!”

PAMELA BAUGHAM, General Manger
Louisa County Water Authority in Louisa, VA
“We are incredibly pleased with the service we receive. Southern Corrosion keeps our water tanks in
tip-top condition.”

TRAVIS MARBURY
Magee’s Creek Water Association in Tylertown, MS
“The customer service has been second to none, the quality of work received has been top notch, and
they have always made sure that our needs have been met and our tanks maintained to their best shape...
I look forward to continuing as a satisfied customer for many years to come.”

JEREMY RANDALL, General Manager
Montmorenci-Couchton Water & Sewer District lnc. in Aiken, SC
“They know what they are doing, and you can’t get a better value for your dollar.”

STEVE HAMILTON
Wayne County Sanitary Districts in Goldsboro, NC
“Small municipalities, like ours, need help keeping our water storage tanks maintained, fully operational
and compliant. Southern Corrosion has provided the Town of Ridgely, Maryland with excellent service
and guidance that is helping to maximize the life of our water tank. We highly recommend Southern
Corrosion for all of your water tank needs.”

DAVID CRIST, Director of Public Works
Ridgely, MD

5

Page 20 of 75

SOUTHERN CORROSION

Testimonials

“Southern Corrosion has been maintaining our tanks for over ten years now. I have been very impressed
by the crews performing our washouts and coating system. Those guys work very efficiently and go the
extra mile from others I have worked with. They maintain a good-looking jobsite during the process of
applying the interior or exterior coating system. They are always conducting themselves in a professional
manner and communicate their progress to our designated contact person. Always great to work with.
Recommend them highly.”

ALAN JOHNSON, Division Director of Water & Wastewater Treatment
Danville, VA
“We signed with Southern Corrosion in 2018 and would not hesitate to recommend their company. They
are readily available for any questions or concerns. Both the sales staff and labor employees are great to
work with. With the company’s suggested ten year maintenance schedule the town can feel confident
that our tank meets the standards that our residents deserve.”

CINDY MCFARLANE
Town of Vienna, MD
“We’ve been Southern Corrosion customers for many years. They do a wonderful job of maintaining our
water tanks and respond instantly if there’s an emergency.”

MACON ROBERTSON
Warren County, NC
“I would recommend Southern Corrosion for anybody’s water tank maintenance needs.”

PATRICK MCBRAYER
Ecru, MS
“Southern Corrosion has been doing tank maintenance for the Benedictine School for years. Their
professional commitment and quality of their workmanship are outstanding. Great Company.”

CARLTON PIPPIN, Facilities Manager, Maintenance
Benedictin in Ridgely, MD
“The service provided by Southern Corrosion has been professional and valuable to the Authority... Southern
Corrosion has made keeping our tanks safe, secure, and in compliance with regulations an easy process.”

JOHN RYBA, Operations Manager
Township of Falls Authority in Fairless Hills, PA

6

Page 21 of 75

SOUTHERN CORROSION

Testimonials

“Iron and manganese continue to be a maintenance item for our community water system as it is for
many systems in eastern North Carolina. Residents and visitors alike want water that tastes good, smells
good, and looks good, but we both know what can happen if our tanks are not properly maintained like
our treatment facilities and distribution systems…We appreciate the work you do and the services you
provide. Your kind of work isn’t for everyone…However, we are fans of yours and and simply want to be
sure it is acknowledged.”

DAVID M. TAWES, Director
Chowan County Water Department in Edenton, NC
“I’m always very satisfied with their work.”

WILL TEASTER
Brown’s Creek Water Association in Union, SC
“We signed with Southern Corrosion in 2018 and would not hesitate to recommend their company. They
are readily available for any questions or concerns. Both the sales staff and labor employees are great to
work with. With the company’s suggested ten year maintenance schedule the town can feel confident
that our tank meets the standards that our residents deserve. We have developed a good rapport with
Southern Corrosion, Inc. over the last five years.”

EDUARDO GONZALES, Assistant Director Public Works & Engineering
Homestead, FL
“…Also to let you know, your work on our water tower has even impressed the town citizens on how
neatly and professionally your work has been and all the local people I have had the opportunity to meet
through my working paths have said nothing but great things and how well your team has done. They
love your work – after all, it is “their” water tower!”

STEVE CALLAHAN, Superintendent, Water and Wastewater Treatment
Towne of Trappe, MD

7

Page 22 of 75

Southern Corrosion Inc.’s Engineered Tank Care Service offers comprehensive coverage for your tank
maintenance needs. The purpose of the service is to extend the life of your tank(s) and their existing
coatings for as long as possible. The service includes corrosion protection, repairs, painting, regularly
scheduled inspections, and a guaranteed emergency response time. The service does not include tasks
associated with the operation of the water system, installation or repair of underground piping, any
structures that are not part of the tank, any electrical work, telemetry, cutting the grass around the tank(s),
or fence maintenance. The service does not include additional modifications to the tank beyond the tank’s
existing configuration unless included in the specifications of our proposal. The service can include
maintenance on the cathodic protection system if the tank(s) is/are equipped with cathodic protection, and
you request this to be included in the service.
As a part of the service, we provide a detailed schedule of exactly what services will be performed in each
year. Also included is an emergency response service that will guarantee a response time to emergency
situations that threaten the immediate use of the tank.
The maintenance service term is based on a mutually agreeable time duration (ie. perpetual). Annual
premiums can be structured monthly, quarterly, or annually. Pick terms that best suit your needs. Also, the
service can be canceled up to 60 days prior to the renewal date for the next year’s service.

THE SERVICE PREMIUM QUOTE COVERS:
________________________________________________________________________________________
1. Emergency Service
2. Regularly scheduled interior washouts when applicable.
3. All interior & exterior cleaning, painting, and repairs.
4. Maintenance and upkeep of the tank.
5. Planning & budgeting for both short-term & long-term maintenance needs.

8

Page 23 of 75

INSURANCE
________________________________________________________________________________________
The sample insurance certificate enclosed provides you with an example of the insurance coverage we will
provide the Customer. We intend to renew our policies at the same coverage levels indicated on the sample
certificate. For your further protection, we will supply you with a pollution liability insurance policy that
protects you from lead contamination claims. For more than 10 years, general liability insurance policies
have specifically excluded coverage for contamination claims. To insure for the liability of improper job site
handling of hazardous wastes, you need this insurance. This insurance is provided at no extra cost. Our
prices do not include the cost of supplying performance and payment bonds. If this is required, our bonding
company is the Great American Insurance Company, of Cincinnati, Ohio. For Southern Corrosion, Inc. to
provide these bonds, please add 3% to all service premiums quoted. If provided, the bonds will be renewed
annually, after the cancellation period for the next year’s service has expired.

VISUAL & WASHOUT INSPECTIONS
________________________________________________________________________________________
Tank(s) will be visually inspected annually. The annual visual inspections have three basic purposes. First,
functional items such as the safety of ladders, the continued operation of float gauges, and the absence or
damage of structural items such as sway rods, struts, etc. can continually be monitored.
Second, the coating system can be visually evaluated for the presence or absence of coating breakdown or
surface holidays. This provides evidence of the rate of deterioration of the coating system, an important
item in determining recoating cycles for the tank, as well as arresting any steel corrosion before it reduces
the effective structural steel thickness.
Third, access can be controlled, especially unauthorized access. Graffiti, vandalism, and the presence or
absence of locked hatches and ladder gates confirm the security level of the tank site.
Additionally, as scheduled, a washout inspection will be performed. A washout inspection includes draining
the tank, removing all sediment and debris, and a complete visual inspection of both the interior and
exterior. All findings will be documented in a bound inspection report, annotated with photographs for
detailing conditions.
Any corrective maintenance needed will be added to the maintenance schedule.

CORROSION PROTECTION & PAINTING
________________________________________________________________________________________
Our maintenance service schedule will detail exactly what maintenance painting will be performed during
regularly scheduled intervals.

9

Page 24 of 75

REPAIRS
________________________________________________________________________________________
Our maintenance service schedule will detail exactly what repairs will be performed during regularly
scheduled intervals.

EMERGENCY RESPONSE
________________________________________________________________________________________
Emergencies that threaten the immediate use of the tank will be responded to within the response time
specified. The response referred to is for the purpose of our assessment of the emergency situation. If
possible, repairs will be completed during the initial response. These emergency repairs are included in the
maintenance service.

AESTHETICS
________________________________________________________________________________________
Feel free to consult with us concerning alternative exterior finish coat color schemes and logos. These items
can be included in the original agreement or can be added to the service.

SAFETY
________________________________________________________________________________________
If needed, the service can include alterations necessary to bring the tank into compliance with current OSHA
regulations or AWWA standards.

GRAFFITI
________________________________________________________________________________________
The service includes the coating over or removal of graffiti one time each year, if required. Removing or
overcoating graffiti is not normally considered an emergency response; it is a scheduled event. If graffiti
appears, we will review the security of the tank site involved, and additional measures may need to be
addressed by the Owner, if it is desired to continue this protection.

10

Page 25 of 75

FUTURE ANTENNA INSTALLATION
________________________________________________________________________________________
Many tank owners choose to defer water tank maintenance costs by leasing their tanks to cellular phone
providers or other communication companies. Such additions can increase future tank maintenance costs if
not designed properly. Under this contract, we will review the installation plans for any antenna installations
to eliminate damage and future maintenance costs to your tank(s) and provide a post installation inspection
to ensure that installation conforms to the approved installation plans.

EXISTING CONDITIONS
________________________________________________________________________________________
This service proposal is based upon the actual structural conditions found on your tanks at the time of the
proposal. Any additions or changes by the Owner (i.e. Antenna installation, sign lighting, etc.) may affect the
maintenance costs included in this service. We reserve the right to re-evaluate or modify this contract if
such a change takes place. (Also see “Future antenna installation”)

ELECTRICAL & ANTENNA TRANSMISSION HAZARDS
________________________________________________________________________________________
Our proposal is based upon the Owner deactivating, or otherwise making safe, any electrical wires or
connections to any tank. OSHA requires that our personnel work at least 15 feet from any “live” electrical
hazards. When applicable, we will protect any antennas and have assumed that the Town will verify that
harmful microwave transmissions do not emanate from any such antennas during our work.

ACCESS TO RECORDS
________________________________________________________________________________________
Our customer records are maintained in a cloud based data system that is accessible from a desktop
computer, notepad, or smartphone. The records maintained include a copy of the contract, recent
inspection reports, and schedule of work. The system we use is also used by Volvo, Deloitte, the National
Football League (NFL), Sony, Time Warner Cable, Sotheby’s and others.

11

Page 26 of 75

Date:
Customer:
Tanks:

May 4, 2026
Town of Front Royal, VA
1,000,000 Gallon Route 522 Hydropillar Water Tank
3,000,000 Gallon Guard Hill Ground Storage Water Tank
3,000,000 Gallon Route 55 Ground Storage Water Tank
100,000 Gallon 4H Ground Storage Water Tank

YEAR 1 - 2026
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.
1. Exterior Roof Painting:
a. Pressure wash all exterior roof surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
c. Apply one spot prime coat of an epoxy-mastic primer to all exterior bare metal surfaces at 2.5 to
3.5 mils dry film thickness.
d. Apply one full finish coat of polyurethane paint to all exterior surfaces at 2.0 to 3.0 mils dry film
thickness.
2. Wash-out Interior Wet and Touch-Up:
a. Owner to have the tank drained.
b. Wash-out tank interior to remove accumulated sediment. Clean interior floor surfaces and shell
wall surfaces that can be reached from the floor using 4,000 psi pressure washers or higher.
c. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
d. Apply one spot coat of a 100% solids epoxy to all cleaned areas.
e. Sterilize the tank interior using AWWA Disinfection Method #2, spray method.
3. Interior Dry Touch-Up of Tank Bowl and Access Tube:
a. Pressure wash all surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
c. Apply one full prime coat of an epoxy-mastic primer to all interior dry tank bowl and access tube
surfaces at 2.5 to 3.5 mils dry film thickness.
d. Apply one full topcoat of an epoxy-mastic primer to all interior dry tank bowl and access tube
surfaces at 2.5 to 3.5 mils dry film thickness.
4. Repairs:
a. Remove the rigid rail fall prevention system from all interior dry and interior wet ladders.
b. Install new cable style fall prevention systems to all ladders.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

12

Page 27 of 75

1. Repairs:
a. Caulk any hole covers on the exterior of the roof that have exposed openings.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repairs:
a. Replace the existing roof vent assembly with a new aluminum frost-free style vent assembly.
b. Apply caulk to the gap between the tank base and foundation to seal any voids.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repairs:
a. Replace the existing roof vent assembly with a new aluminum frost-free style vent assembly.

YEAR 2 - 2027
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 3 - 2028
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Wash-out Interior:
a. Owner to have the tank drained.
b. Wash-out tank interior to remove accumulated sediment. Clean interior floor surfaces and shell
wall surfaces that can be reached from the floor using 4,000 psi pressure washers or higher.
c. Sterilize the tank interior using AWWA Disinfection Method #2, spray method.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 4 - 2029
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

13

Page 28 of 75

1. Repaint Exterior:
a. Pressure wash all exterior surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
c. Apply one spot prime coat of an epoxy-mastic primer to all exterior bare metal surfaces at 2.5 to
3.5 mils dry film thickness.
d. Apply one full finish coat of polyurethane paint to all exterior surfaces at 2.0 to 3.0 mils dry film
thickness.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 5 - 2030
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Wash-out Interior:
a. Owner to have the tank drained.
b. Wash-out tank interior to remove accumulated sediment. Clean interior floor surfaces and shell
wall surfaces that can be reached from the floor using 4,000 psi pressure washers or higher.
c. Install a cable style fall prevention system to the interior shell wall ladder.
d. Sterilize the tank interior using AWWA Disinfection Method #2, spray method.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Exterior:
a. Pressure wash all exterior surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
c. Apply one spot prime coat of an epoxy-mastic primer to all exterior bare metal surfaces at 2.5 to
3.5 mils dry film thickness.
d. Apply one full finish coat of polyurethane paint to all exterior surfaces at 2.0 to 3.0 mils dry film
thickness.
2. Wash-out Interior:
a. Owner to have the tank drained.
b. Wash-out tank interior to remove accumulated sediment. Clean interior floor surfaces and shell
wall surfaces that can be reached from the floor using 4,000 psi pressure washers or higher.
c. Install a cable style fall prevention system to the interior shell wall ladder.
d. Sterilize the tank interior using AWWA Disinfection Method #2, spray method.

14

Page 29 of 75

YEAR 6 - 2031
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.
1. Wash-out Interior:
a. Owner to have the tank drained.
b. Wash-out tank interior to remove accumulated sediment. Clean interior floor surfaces and shell
wall surfaces that can be reached from the floor using 4,000 psi pressure washers or higher.
c. Sterilize the tank interior using AWWA Disinfection Method #2, spray method.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 7 - 2032
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 8 - 2033
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Interior:
a. Abrasive blast all rusted interior surfaces to bare metal in accordance with SSPC surface
preparation method #10, near white grade. Abrasive blast all remaining interior surfaces in
accordance with SSPC surface preparation method #7, brush blast.
b. Apply a full prime coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
c. Apply a “stripe coat” of epoxy to all weld seams and ladders, applied using paint brushes and
rollers.
d. Apply a full finish coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.

15

Page 30 of 75

e. Caulk unwelded roof lap seams using Sikaflex 1a polyurethane caulk.
f. Sterilize interior using AWWA Disinfection Method #2, spray method.
g. Test abrasive blast debris for the 8 RCRA heavy metals using the TCLP Method.
h. Dispose of abrasive blast debris in accordance with Federal, State, and Local regulations.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 9 - 2034
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

YEAR 10 - 2035
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Interior:
a. Abrasive blast all rusted interior surfaces to bare metal in accordance with SSPC surface
preparation method #10, near white grade. Abrasive blast all remaining interior surfaces in
accordance with SSPC surface preparation method #7, brush blast.
b. Apply a full prime coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
c. Apply a “stripe coat” of epoxy to all weld seams and ladders, applied using paint brushes and
rollers.
d. Apply a full finish coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
e. Caulk unwelded roof lap seams using Sikaflex 1a polyurethane caulk.
f. Sterilize interior using AWWA Disinfection Method #2, spray method.
g. Test abrasive blast debris for the 8 RCRA heavy metals using the TCLP Method.
h. Dispose of abrasive blast debris in accordance with Federal, State, and Local regulations.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Exterior:
a. Pressure wash all exterior surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.

16

Page 31 of 75

c. Apply one spot prime coat of an epoxy-mastic primer to all exterior bare metal surfaces at 2.5 to
3.5 mils dry film thickness.
d. Apply one full finish coat of polyurethane paint to all exterior surfaces at 2.0 to 3.0 mils dry film
thickness.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Interior:
a. Abrasive blast all rusted interior surfaces to bare metal in accordance with SSPC surface
preparation method #10, near white grade. Abrasive blast all remaining interior surfaces in
accordance with SSPC surface preparation method #7, brush blast.
b. Apply a full prime coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
c. Apply a “stripe coat” of epoxy to all weld seams and ladders, applied using paint brushes and
rollers.
d. Apply a full finish coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
e. Caulk unwelded roof lap seams using Sikaflex 1a polyurethane caulk.
f. Sterilize interior using AWWA Disinfection Method #2, spray method.
g. Test abrasive blast debris for the 8 RCRA heavy metals using the TCLP Method.
h. Dispose of abrasive blast debris in accordance with Federal, State, and Local regulations.

YEAR 11 - 2036
_____________________________________________________________________________________

1,000,000 Gallon Route 522 Hydropillar Water Tank
Visual inspection and repairs uncovered through inspection.
1. Repaint Exterior:
a. Pressure wash all exterior surfaces using 4,000 psi pressure washers or higher.
b. Clean all rusted areas using scrapers, hand & power wire brushes in accordance with SSPC
surface preparation methods #2 & #3, hand & power tool cleaning.
c. Apply one spot prime coat of an epoxy-mastic primer to all exterior bare metal surfaces at 2.5 to
3.5 mils dry film thickness.
d. Apply one full finish coat of polyurethane paint to all exterior surfaces at 2.0 to 3.0 mils dry film
thickness.
2. Repaint Interior Wet:
a. Abrasive blast all rusted interior surfaces to bare metal in accordance with SSPC surface
preparation method #10, near white grade. Abrasive blast all remaining interior surfaces in
accordance with SSPC surface preparation method #7, brush blast.
b. Apply a full prime coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
c. Apply a “stripe coat” of epoxy to all weld seams and ladders, applied using paint brushes and
rollers.
d. Apply a full finish coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
e. Caulk unwelded roof lap seams using Sikaflex 1a polyurethane caulk.
f. Sterilize interior using AWWA Disinfection Method #2, spray method.
g. Test abrasive blast debris for the 8 RCRA heavy metals using the TCLP Method.

17

Page 32 of 75

h. Dispose of abrasive blast debris in accordance with Federal, State, and Local regulations.
3. Repaint Interior Dry:
a. Remove the jacketing and insulation from the fill pipe so it can blasted and painted.
b. Abrasive blast all rusted interior surfaces to bare metal in accordance with SSPC surface
preparation method #6, commercial grade. Abrasive blast all remaining interior surfaces in
accordance with SSPC surface preparation method #7, brush blast.
c. Apply a full prime coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
d. Apply a full finish coat of epoxy that is NSF approved for contact with potable water to all
interior surfaces at 4.0 to 6.0 mils dry film thickness.
e. Test abrasive blast debris for the 8 RCRA heavy metals using the TCLP Method.
f. Dispose of abrasive blast debris in accordance with Federal, State, and Local regulations.

3,000,000 Gallon Guard Hill Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

3,000,000 Gallon Route 55 Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

100,000 Gallon 4H Ground Storage Water Tank
Visual inspection and repairs uncovered through inspection.

SCHEDULE CONTINUATION
_____________________________________________________________________________________
The tank will be visually inspected every year. The tank interior will be washed-out at 5-year intervals until
15 years has elapsed from the last time the interior was recoated. The tank interior will be recoated at 15year intervals and the tank exteriors will be recoated at 10-year intervals.

AFTER YEAR 11:
1,000,000 Gallon Route 522 Hydropillar Water Tank
The next wash-out is scheduled for Year 16 of the Service (Year 2041), the next repainting of the tank
exterior is scheduled for Year 21 of the Service (Year 2046), and the next repainting of the tank
interior is scheduled for Year 26 of the Service (2051).

3,000,000 Gallon Guard Hill Ground Storage Water Tank
The next wash-out is scheduled for Year 15 of the Service (Year 2040), the next repainting of the tank
exterior is scheduled for Year 14 of the Service (Year 2039), and the next repainting of the tank
interior is scheduled for Year 25 of the Service (2050).

3,000,000 Gallon Route 55 Ground Storage Water Tank
The next wash-out is scheduled for Year 13 of the Service (Year 2038), the next repainting of the tank
exterior is scheduled for Year 20 of the Service (Year 2045), and the next repainting of the tank
interior is scheduled for Year 23 of the Service (2048).

100,000 Gallon 4H Ground Storage Water Tank
The next wash-out is scheduled for Year 15 of the Service (Year 2040), the next repainting of the tank
exterior is scheduled for Year 15 of the Service (Year 2040), and the next repainting of the tank
interior is scheduled for Year 25 of the Service (2050).

18

Page 33 of 75

At no time does the service include the complete abrasive blasting of the tank exteriors nor the pressure
washing of any tank exteriors as a stand-alone maintenance item apart from being a surface preparation
method for painting.
Exterior painting and logos are priced based on using the same color paint and logo designs. Unless
specified in the scope of work any exterior color or logo change request may result in a premium increase
and/or an additional one-time charge.

PRICING & TERMS
_____________________________________________________________________________________
Necessary repair of any coatings or appurtenances noted during our inspections will be added to our
service schedule at no additional cost. These necessary repairs include paint failed areas and areas of
corrosion. If the coating is continuing to protect the steel from corrosion, paint repair is not necessary.
The definition of paint failure does not include loss of gloss, color fading, mildew, discoloration, or any
other defects that are aesthetic
Emergency service will apply during the entire period. We will guarantee a 24-hour response time.
Corrective maintenance noted during our inspections will be added to our schedule at no added expense.
Our annual premium for the first year of the service is $127,722.00. All subsequent year premiums will be
the total of the immediate prior year’ s premium amount plus the % change in the CPI (Consumer Price
Index) for that previous year (ie. Year 2 premium equals Year 1 premium plus the % change in the CPI for
Year 1).

THIS PRICE IS FIRM FOR 30 DAYS.
Each year represents a 12-month period beginning with the effective date of the contract, rather than the
actual calendar year. The Owner will be given the opportunity to schedule the yearly work at any time
during the 12-month period that represents the contract term. The annual premium is due within 30 days
of the contract date. Payment can be made monthly, quarterly, semi-annually, or annually.

19

Page 34 of 75

This Agreement made and entered into as of the Effective Date:__________________ , by and between
SOUTHERN CORROSION, INC., a North Carolina corporation, having its principle office at 524 NC Hwy 125,
Roanoke Rapids, North Carolina, (hereinafter referred to as "Southern Corrosion") and the Town of Front
Royal, VA (hereinafter referred to as the "Owner"):

WITNESSETH
___________________________________________________________________________________________
The Owner desires that Southern Corrosion perform certain maintenance service on the water tanks known as
the 1,000,000 Gallon Route 522 Hydropillar Water Tank, the 3,000,000 Gallon Guard Hill Ground Storage
Water Tank, the 3,000,000 Gallon Route 55 Ground Storage Water Tank, and the 100,000 Gallon 4H Ground
Storage Water Tank, as described in the proposal which is attached hereto and by reference made a part here
of (the "Maintenance Services"); and Southern Corrosion desires to perform such Maintenance Services
described in said proposal selected by the Owner upon the terms and conditions set forth in this Agreement.

DRAFT

Now, therefore, in consideration of the mutual promises and covenants set forth herein the parties hereto
agree as follow:
1. DEFINITIONS. For the purposes of this Agreement, the following definitions apply:
a. "Effective date" shall mean the date on which this Agreement, executed by the Owner, is accepted by
Southern Corrosion by the execution thereof by its appropriate corporate officers at its principal office.
2. TERMS OF MANAGEMENT AGREEMENT. The initial term of this Agreement shall be for a period of twelve
(12) months commencing on the Effective Date, unless otherwise terminated or canceled as provided in
Paragraph 7. The initial term shall be automatically extended successive additional periods of twelve (12)
months each unless the Owner notifies Southern Corrosion in writing sixty (60) days prior to the expiration of
the then existing term that it does not extend this Agreement. In accordance with the provisions of §2.2-4304
of the Virginia Public Procurement Act, this contract is entered into utilizing the Professional Tank Maintenance
Services RFP-2025-04, Town of Wytheville, VA.
3. PERFORMANCE OF MAINTENANCE SERVICES. Southern Corrosion shall perform the Maintenance Services
selected by the Owner and described in proposal attached hereto and by reference made a part hereof.
4. CHARGES. The Owner shall pay Southern Corrosion charges for Maintenance Services selected by Owner as
set forth on the proposal attached hereto and by reference made a part hereof. All charges shall be due and

20

Page 35 of 75

payable upon receipt of Southern Corrosion's invoice therefor.
5. REPRESENTATIONS BY THE OWNER. The Owner hereby makes the following representations and
warranties:
a. The Owner has full power and lawful authority to execute and deliver this Agreement and to consummate
and perform the transactions contemplated hereby. This Agreement constitutes the valid obligation of the
Owner legally binding upon the Owner and enforceable against the Owner in accordance with its terms.
6. REPRESENTATIONS BY SOUTHERN CORROSION. Southern Corrosion represents and warrants to Owner all
of which represents and warranties that:
a. That Southern Corrosion is fully authorized to enter into this Management Agreement. Southern Corrosion
has full corporate power and lawful authority to execute and deliver this Agreement and to consummate and
perform the transactions contemplated hereby. This Agreement constitutes the valid obligation of Southern
Corrosion legally binding upon Southern Corrosion and enforceable against Southern Corrosion in accordance
with its terms.

DRAFT

7. TERMINATION/CANCELLATION. This Agreement may be terminated/canceled by Southern Corrosion if
Owner is in default of any provision hereof and such default has not been cured within twenty (20) days after
notice of default is given to Owner or Owner becomes insolvent or seeks protection voluntarily or involuntarily
under any Bankruptcy Law.
a. In the event of any termination/cancellation of this Agreement, Southern Corrosion may (1) declare all
amounts owed to Southern Corrosion to be immediately due and payable, (2) cease performance of all
Maintenance Service hereunder without liability to Owner.
b. In the event of default hereunder, Owner agrees to pay interest at the highest legal rate on all sums due
under the Agreement and all costs of collection including a reasonable attorney's fee of fifteen percent (15%) of
said amount due Southern Corrosion.
c. The foregoing rights and remedies shall be cumulative and in addition to all other rights and remedies
available in law or in equity to Southern Corrosion.
8. LIMITATION OF LIABILITY. In no event shall Southern Corrosion be liable to Owner for indirect, special or
consequential damages or lost profits arising out of or related to this Management Agreement of the
performance or breach thereof even if Southern Corrosion has been advised of the possibility thereof. Southern
Corrosion's liability to Owner hereunder if any, shall in no event exceed the total of the amounts Owner has
paid Southern Corrosion hereunder.
9. EXCUSABLE DELAY. Southern Corrosion shall not be liable for any delays or failure in performance of
Maintenance Services hereunder if such delays or failures are due to strikes, inclement weather, acts of God or
other causes beyond Southern Corrosion’s reasonable control.
10. REGULATIONS. Performance of the Maintenance Services is predicated on work practices, methods, and
21

Page 36 of 75

procedures legal as of the effective date. Subsequently enacted regulations that effect or alter Southern
Corrosion's work practices, methods, and procedures, to perform, or add additional burdens to performance,
will be grounds for renegotiating the amount of payment originally agreed upon.
11. GENERAL.
a. Notices. Notice of the breach of any covenant, warranty or other provision of the Agreement and all
communications and notices provided for in this Agreement shall be deemed given when in writing, addressed
to the parties at the addresses set forth below, and deposited, certified mail, postage prepaid in the United
States mail:
Owner:
Town of Front Royal
102 E Main Street
Front Royal, VA 22630

Southern Corrosion Inc.
524 NC Hwy 125
Roanoke Rapids, NC 27870

b. Assignment. This Agreement may not be assigned by either party without the prior written consent of the
other party, which consent by either party shall not be unreasonably withheld.

DRAFT

c. Governing Law. This Agreement shall be construed in accordance with the laws of the State of Virginia.
d. Entire Agreement. This Agreement is an integrated document and contains the entire agreement between
the parties. No modifications, extensions, or waiver of this Agreement or any of the provisions hereof, nor any
representation, promise or condition relating to the Agreement shall be binding upon the parties hereto unless
made in writing and signed by the parties hereto.
e. Binding effects. The provisions of this Agreement shall bind and insure to the benefit of Southern Corrosion
and the Owner, and their successors, legal representatives and assigns.

IN WITNESS WHEREOF the parties have hereto executed this Agreement in the manner provided by Law, this
the day and year first above written.
ATTEST:
_____________________________________
Asst. Secretary

SOUTHERN CORROSION, INC.
BY: _____________________________________
President

(Corporate Seal)

ATTEST:
_____________________________________

TOWN OF FRONT ROYAL
BY: _____________________________________

22

Page 37 of 75

SOUTCOR-02

JCOLLINSJHA
DATE (MM/DD/YYYY)

CERTIFICATE OF LIABILITY INSURANCE

3/3/2026

THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
CONTACT Brittany Taylor
NAME:
PHONE
FAX
(A/C, No, Ext):
(A/C, No): (252) 451-9400
E-MAIL
ADDRESS: [email protected]

PRODUCER

Oakbridge Insurance Agency
950 Country Club Road
Rocky Mount, NC 27804

INSURER(S) AFFORDING COVERAGE

NAIC #

INSURER A : Evanston Insurance Company

35378
12572
INSURER B : Selective Insurance Company Of America
INSURER C : American Interstate Insurance Company Of Texas 12228

INSURED

Southern Corrosion, Inc.
524 NC 125
Roanoke Rapids, NC 27870

INSURER D :
INSURER E :
INSURER F :

COVERAGES

CERTIFICATE NUMBER:

REVISION NUMBER:

THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR

A

ADDL SUBR
INSD WVD

TYPE OF INSURANCE

X

POLICY NUMBER

POLICY EFF
POLICY EXP
(MM/DD/YYYY) (MM/DD/YYYY)

COMMERCIAL GENERAL LIABILITY
CLAIMS-MADE

OCCUR

GSEV000021-00

3/3/2026

3/3/2027

GEN'L AGGREGATE LIMIT APPLIES PER:
PROX POLICY
LOC
JECT
OTHER:

B

$

MED EXP (Any one person)

$

PERSONAL & ADV INJURY

$

GENERAL AGGREGATE

$

PRODUCTS - COMP/OP AGG

$

COMBINED SINGLE LIMIT
(Ea accident)

AUTOMOBILE LIABILITY

X

LIMITS

EACH OCCURRENCE
DAMAGE TO RENTED
PREMISES (Ea occurrence)

ANY AUTO
OWNED
AUTOS ONLY
HIRED
AUTOS ONLY

SCHEDULED
AUTOS
NON-OWNED
AUTOS ONLY

UMBRELLA LIAB

X

S2677950

3/3/2026

3/3/2027

BODILY INJURY (Per person)

$

1,000,000
100,000
5,000
1,000,000
2,000,000
2,000,000

$
$

1,000,000

$

BODILY INJURY (Per accident) $
PROPERTY DAMAGE
(Per accident)
$
$

A

X

EXCESS LIAB

DED

C

X

OCCUR

RETENTION $

WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY
ANY PROPRIETOR/PARTNER/EXECUTIVE
OFFICER/MEMBER EXCLUDED?
(Mandatory in NH)
If yes, describe under
DESCRIPTION OF OPERATIONS below

A Pollution Liability
A Professional Liab

GSXS000003-00

CLAIMS-MADE

3/3/2026

3/3/2027

EACH OCCURRENCE

$

AGGREGATE

$

0
X
Y/N

AVWCNC3461772026

3/3/2026

3/3/2027

N/A

PER
STATUTE

OTHER

E.L. EACH ACCIDENT

$

$

E.L. DISEASE - EA EMPLOYEE $
E.L. DISEASE - POLICY LIMIT

GSEV000021-00
GSEV000021-00

3/3/2026
3/3/2026

3/3/2027
3/3/2027

Aggregate
Aggregate

5,000,000
5,000,000

$

1,000,000
1,000,000
1,000,000
2,000,000
2,000,000

DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)

CERTIFICATE HOLDER

SAMPLE

CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE

ACORD 25 (2016/03)

© 1988-2015 ACORD CORPORATION. All rights
reserved.
23
The ACORD name and logo are registered marks of ACORD

Page 38 of 75

COUNCIL REGULAR WORK SESSION
AGENDA STATEMENT

Meeting Date: May 11, 2026

Item#

4B

Agenda Item:

Purchase of Replacement Bucket Truck for Department of Energy

Summary:

Council is requested to approve the purchase of a 2026 Altec AT41M (41’ Articulating
Telescopic Aerial Device with Material Handling) bucket truck for the Department of
Energy Services. This vehicle will replace Unit #364, a 2017 Ford F550 Verralift VST40.
The procurement will be made through cooperative contracting using a Sourcewell
contract with Altec Industries, Inc. Contract #0421-ALT. Staff obtained a quote from
Altec Industries, Inc., Richmond, Virginia, in the amount of $204,912.00.
Funding is available within the Electric – Motor Vehicles FY26 operating budget, which
includes $138,044.86 for this vehicle replacement and $66,867.14 encumbered on PO
30441.

Budget/Funding:

9401-47005
9401-R47005

Electric – Motor Vehicles
Electric – Motor Vehicles (PO 30441)

$138,044.86
$ 66,867.14

Staff Recommendation: Staff recommends approving the award of contract as presented.

Page 39 of 75

Town of Front Royal
Department of Energy Services

P.O. Box 1560
Front Royal, Virginia 22630-1560
(540) 635-3027 Fax: (540) 631-3620
“Powering the community since 1894”

Memo
To:

The Purchasing Department

From:

Carey Saffelle, Director of Energy Services

Date:

May 5th, 2026

Re:

Replacement of Bucket Truck 364

The Director of Auto Maintenance has obtained pricing from Altec through the Sourcewell
Contract for the replacement of Bucket Truck #364, with the attached quote reflecting a Bucket
Truck with an F600 4x4 Chassis at a total cost of $204,912.00.
The Department of Energy Services has all funds allocated for this purchase.
Thank you,
Carey Saffelle
Director
Department of Energy Services
Town of Front Royal

Page 40 of 75

Quote Number:

1853041 - 1

Altec, Inc.
May 5th, 2026
Ship To:

Bill To:
TOWN OF FRONT ROYAL
PO BOX 1560
FRONT ROYAL, VA 22630-0033
United States

TOWN OF FRONT ROYAL
800 CROSBY RD
FRONT ROYAL, VA 22630-3496
US
Attn: CAREY SAFFELLE
Phone: 540-6353027
Email: [email protected]
Altec Quotation Number:
Account Manager:
Technical Sales Rep:

Item

1853041 - 1
Luke A Mansfield
Abbott Tobin Gaddy

Description

Qty

Price

Unit
1.

Altec Model AT41M Articulating Telescopic Aerial Device with a fiberglass upper boom
and fiberglass insulator in the articulating arm and proportional joystick upper controls.
Built in accordance to ALTEC's standard specifications and to include the following
features:
A.
B.
C.
D.
E.
F.
G.

H.

I.
J.

1

Ground to Bottom of Platform Height: 40.8 feet at 7.3 feet from centerline of
rotation (12.45 m at 2.21 m)
Working Height: 45.8 feet (13.96 m)
Maximum reach to edge of platform with Upper Boom Non- overcenter: 30.1 feet
(at 17.3 feet platform height)
Upper boom extension: 110 inches
Continuous rotation
Articulating Arm: Articulation is from -3 to 82 degrees. Insulator provides 19
inches of isolation.
Compensation System: By raising the articulating arm only, the telescopic boom
maintains its relative angle in relation to the ground. The work position is
achieved through a single function operation.
Upper Boom: Articulation is from -25 to 85 degrees. The fiberglass section
provides a minimum of 10.9 inches of isolation in the upper boom (when retracted
and 42.3 inches when extended).
Platform leveling is achieved by a hydraulic master-slave leveling system. This
lifetime system is very low maintenance.
The dielectrically tested, insulating upper control system includes the following
boom tip components that can provide an additional layer of secondary electrical
contact protection.
Control Handle: A single handle controller incorporating high electrical resistance
components that is dielectrically tested to 40 kV AC with no more than 400
microampers of leakage. The control handle is green in color to differentiate it
from other non-tested controllers. The handle also includes an interlock guard
that reduces the potential for inadvertent boom operation.
Auxiliary Control Covers: Non-tested blue silicon covers for auxiliary controls.
Control Console: Non-tested non-metallic control console plate.
Boom Tip Covers: Non-tested non-metallic boom tip covers. The covers are not
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 1 of 10

Page 41 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description

K.
L.
M.

N.

O.

Qty

Price

dielectrically tested, but they may provide some protection against electrical
hazards.
Hydraulic system: Open center (full pressure), maximum flow 6 GPM, maximum
operating pressure 3,000.
Dielectric rating: Category C, 46 kV and below
Unit is painted with a powder coat paint process which provides a finish-painted
surface that is highly resistant to chipping, scratching, abrasion and corrosion.
Paint is electrostatically applied to the inside as well as outside of fabricated parts
then high temperature cured prior to assembly ensuring maximum coverage and
protection.
Manuals: Two (2) Operator's and Maintenance/Parts Manuals. One(1) in printed
format and one(1) in electronic format available at connect.altec.com containing
instructional markings indicating hazards inherent in the operation of an aerial
device.
Unit meets or exceeds ANSI 92.2 standards.

2.

Pedestal

1

3.

Single 1-Man Platform, Fiberglass, 24" x 30" x 42", End Mount, 180 Degree Rotation

1

4.

Platform Mounted Single Handle Controls

1

5.

Material Handling Jib/Winch, Hydraulically Articulating, Top Mounted, Round (ARM Jib)

1

6.

One (1) Platform Step - located on the side of the platform nearest the elbow in the
stowed position

1

7.

Platform Cover - soft vinyl, 24 x 30 inches (610 x 762 mm)

1

8.

Platform Liner, 24 x 30 x 42 inches (610 x 762 x 1067 mm), 50 kV Rating

1

9.

Hydraulic Tool Circuit at Platform: One set of quick disconnect couplings at the boom tip
for open center tools.

1

10.

Engine Start/Stop & Secondary Stowage System: 12 VDC powered motor and pump
assembly for temporary operation of the unit in a situation wherein the primary hydraulic
source fails. Electric motor is powered by the chassis battery. This feature allows the
operator to completely stow the booms, platform, and outriggers. Secondary Stowage &
Start/Stop is activated with an air plunger at the platform or momentary switch at the
lower control station and outriggers.

1

11.

Jib Stick, 36" L, non-extension, non certified, grey in color

1

12.

Slip Ring: Required for engine start/stop, secondary stowage system, and throttle control
options

1

13.

Outriggers, Primary, Modified A-Frame With Integrated Subbase, 30''-34'' Chassis
Height, Electric Interlock, No Valves On Legs, 114'' Spread, Fixed Shoe (AT37/41
M/ME/P/PE/S/SE)

1

14.

Winch load line swivel hook

1

15.

Altec Unit Powder Painted White

1
Unit & Hydraulic Acc.
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 2 of 10

Page 42 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description

Qty

16.

Scuff Pad, 24" x 30", No Step (For use with Platform Liner)

1

17.

Electric Outrigger Controls for one (1) set of outriggers, drive hydraulic outrigger control
valves. Durable weather proof sealed electronic switches mounted in aluminum boxes
located at the rear of the unit unless otherwise specified.

1

18.

Hydraulic Reservoir, 15 Gallon, Rectangular, 22" L x 8.5" W x 24" H, and includes
breather caps and dipsticks

1

19.

Temperature Sight Gauge

1

20.

Hydraulic Oil HVI-22 with Dye (Standard)

25

21.

Standard Pump For PTO

1

22.

Electric Shifted PTO

1

23.

Standard PTO/Transmission Functionality for Small Ford and Dodge Chassis

1

Price

Body
24.

Altec LGSS-132-84 (81) low-side general service body with step:
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.

1

Steel body
Steel structural channel crossmembers and smooth floor with ladder-style
understructure
132 in body length
94 in body width
40 in body compartment height
20 in body compartment depth
24 in from body floor to compartment tops
Finish paint entire body Altec white
Undercoat applied under the body
5.5 in drop-in wooden cargo retaining board at rear of body
5.5 in drop-in wooden retaining board at top of side access step
Stainless steel rotary paddle latches with locks
Gas props on all vertical doors
Chains on all horizontal doors
Standard master body locking system
Hotstick shelf extending full length of body on streetside
Two (2) hotstick brackets Installed on streetside
Standard drop-down hotstick door for one (1) shelf on streetside, stainless steel
slam paddle latch with keyed lock
One chock holder on each side of body with retaining lip In fender panel
Adhesive strip lighting (LED) around top and sides of compartment door facings
1st vertical (SS) - 34 in w - One (1) outrigger housing and two (2) adjustable
shelves with removable dividers on 4 in centers
2nd vertical (SS) - 24 in w - Two (2) adjustable shelves with removable dividers
on 4 in centers
1st horizontal (SS) - 50 in w - One (1) fixed shelf with removable dividers on 4 in
centers on bottom of compartment
Rear vertical (SS) - 24 in w - Six (6) locking swivel hooks on an adjustable rail (14-1)
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 3 of 10

Page 43 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description
Y.
Z.
AA.

AB.
AC.
AD.
AE.
AF.

Qty

Price

1st vertical (CS) - 34 in w - One (1) outrigger housing and two (2) adjustable
shelves with removable dividers on 4 in centers
2nd vertical (CS) - 24 in w - Gripstrut access steps with two (2) sloped grab
handles, vented battery storage
1st horizontal (CS) - 50 in w - One (1) adjustable shelf with removable dividers on
4 in centers and one (1) fixed shelf with removable dividers on 4 in centers on
bottom of compartment
Rear vertical (CS) - 24 in w - Six (6) locking swivel hooks on an adjustable rail (14-1)
Body floor cut-out for AT41M/ME/P/PE aerial device near front of body
Steel tailshelf, 29 in l x 94 in w, with rear cross storage and drop down doors
Two (2) wire thru channels at bulkhead with cover
Underbody channels on streetside and curbside for wiring/plumbing
Body and Chassis Accessories

25.

Underride Protection Bumper Installed At Rear

1

26.

Combination 2 Ball (10 000 LB MGTW) and Rigid Pintle Hitch (16 000 LB MGTW with 3
000 LB MVL), 4-Bolt, Buyers BH82000

1

27.

Set Of Eye Bolts for Trailer Safety Chain, installed one each side of towing device
mount.

1

28.

Rigid Step Mounted Beneath Side Access Steps (Installed To Extend Approx. 2''
Outward)

1

29.

Platform Rest, Rigid with Rubber Tube

1

30.

Boom Rest for a Telescopic Unit

1

31.

Wood Outrigger Pad, 19'' x 19'' x 2.5'', With Rope Handle

2

32.

Outrigger Pad Holder, 20'' L x 20'' W x 5'' H, Fits 19.5'' x 19.5'' x 4'' And Smaller Pads,
Bolt-On, Bottom Washout Holes, 3/4'' Lip Retainer

2

33.

Pendulum Retainers For Outrigger Pad Holders

2

34.

Mud Flaps With Altec Logo (Pair)

1

35.

Wheel Chocks, Rubber, 9.75'' L x 7.75'' W x 5.00'' H, with 4'' L Metal Hairpin Style
Handle (Pair)

1

36.

Slope Indicator Assembly (Pair) For Machine With Outriggers

1

37.

Safety Harness & 4.5 FT Lanyard (Medium To X-large)

1

38.

Driveaway Safety Kit

1

39.

Vinyl manual pouch for storage of all operator and parts manuals

1

Electrical Accessories
40.

Compartment Lights Wired To Dash Mounted Master Switch
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

1

Page 4 of 10

Page 44 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description

Qty

41.

Lights and reflectors in accordance with FMVSS #108 lighting package. (Complete LED,
including LED reverse lights)

1

42.

4-Corner Strobes, Amber, LED, Two (2) Surface Mounted Lights In Grille, Two (2)
Round Lights At Rear

1

43.

Strobe Beacons, Amber LED, with Brush Guard, Installed on Post at Front of Body, One
(1) Each Side (Standard) (Tecniq #K10-AAAD-1)

1

44.

Dual Tone Back-Up With Outrigger Motion Alarm

1

45.

PTO Hour Meter, Digital, with 10,000 Hour Display

1

46.

6-Way Trailer Receptacle (Pin Type) Installed At Rear

1

47.

Ford Upfitter Switches (Supplied with Chassis)

1

48.

Power Distribution Module (PDM-6A), 6 Accessory Circuits, CAN Signals, Installed,
Chevy/International CV, Ford, Dodge

1

49.

Install Chassis (OEM) Supplied Backup Camera in Final Assembly

1

50.

Install secondary stowage system.

1

51.

Install Remote Start/Stop system in Final Assembly.

1

52.

Install Outrigger Interlock System

1

53.

Heavy Duty Secondary Stowage Pump

1

54.

One Emergency Stop Located at Ground Level Installed at the Rear of the Vehicle

1

55.

PTO Indicator Light Installed In Cab

1

Price

Finishing Details
56.

Powder Coat Unit Altec White

1

57.

Finish Paint Body Accessories Above Body Floor Altec White

1

58.

Altec Standard; Components mounted below frame rail shall be coated black by Altec.
i.e. step bumpers, steps, frame extension, pintle hook mount, dock bumper mounts, Drings, receiver tubes, accessory mounts, light brackets, under-ride protection, etc.
Components mounted to under side of body shall be coated black by Altec. i.e. Wheel
chock holders, mud flap brackets, pad carriers, boxes, lighting brackets, steps, and
ladders.

1

59.

Apply Non-Skid Coating to all walking surfaces

1

60.

English Safety And Instructional Decals

1

61.

Vehicle Height Placard - Installed In Cab

1

62.

Placard, HVI-22 Hydraulic Oil

1

63.

Dielectric test unit according to ANSI requirements.

1

We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 5 of 10

Page 45 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description

Qty

64.

Stability test unit according to ANSI requirements.

1

65.

Focus Factory Build

1

66.

Delivery Of Completed Unit

1

67.

Inbound Freight

1

68.

As Built Electrical And Hydraulic Schematics To Be Included In The Manual Pouch

1

69.

Stock Unit

1

Price

Chassis
70.

Altec Supplied Chassis

1

71.

Altec Stock Chassis

1

A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
AA.
AB.
AC.
AD.
AE.
AF.
AG.
AH.

2026 Model Year
Ford F600
Chassis Cab
Regular Cab
4x4
Chassis Color - White
Ford 6.7L Power Stroke Diesel
Diesel
330 HP Engine Rating
Ford Torqshift 10-Speed Automatic Transmission (w/PTO Provision)
84 Clear CA (Round To Next Whole Number)
Chassis Wheelbase Length - 169
GVWR 22,000 LBs
7,500 LBS Front GAWR
15,500 LBS Rear GAWR
Spring Suspension
Ford E/F250-550 Single Horizontal Right Side Exhaust
Hydraulic Brakes
Park Brake In Rear Wheels
Ford 40 Gallon Fuel Tank (Rear)
Ford 7.2 Gallon DEF Tank (Mid Mount)
Dual Rear Wheel
245/70R19.5 Front Tire
All-Position Tires, Front
245/70R19.5 Rear Tire
All-Position Tires, Rear
99T - Operator Commanded Regeneration (OCR)
63C - Aft Axle Frame Extension
872 - Rear View Camera and Prep Kit
No Idle Engine Shut-Down Required
50-State Emissions
CARB Compliant
Clean Idle Certification
12V DC Power Outlet
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 6 of 10

Page 46 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Item

Description
AI.
AJ.
AK.
AL.
AM.
AN.
AO.
AP.
AQ.
AR.
AS.
AT.
AU.
AV.
AW
.
AX.
AY.
Az.
BA.
BB.

Qty

Price

AM/FM Radio
Air Conditioning
Backup Camera, OEM Supplied
Block Heater
Collision Mitigation System
Cruise Control
Dual Alternator (300 amp Minimum)
Ford SYNC
Keyless Entry
Limited Slip Rear Axle
Power Door Locks
Power Windows
Running Boards (Supplied By Chassis OEM)
Side Mirrors, Power Adjusting, Manual Folding, Manual Telescoping with Heated
Glass
Skid Plate
Tachometer
Tilt Steering Wheel
Trailer Brake Controller (Factory Installed)
XL Trim Package
Vinyl Split Bench Seat
Additional Pricing

Standard Altec Warranty: One (1) year parts warranty, one (1) year labor warranty,
ninety (90) days warranty for travel charges, limited lifetime structural warranty

72.

1

Miscellaneous
Non-CARB Registered State

73.

1

Unit / Body / Chassis Total
Additional Total
FET Total
Total

204,912.00
0.00
0.00
204,912.00

Altec Industries, Inc.
BY

Abbott Tobin Gaddy
Notes:
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 7 of 10

Page 47 of 75

Quote Number:

1853041 - 1

Altec, Inc.

1

Altec will make every effort to honor this quotation, subject to the following provisions. Prices for equipment
with production start dates 12 months and beyond are budgetary only due to irregular cost inflation and
market volatility. These prices will be reviewed based on market conditions and confirmed closer to the
production date.
For a quoted chassis model year beyond the current open order bank, chassis model year, specifications
and price should be considered estimates only and subject to change. Chassis model year, specifications
and price will be reviewed and confirmed when specific model year information becomes available from the
OEM.

2

Estimated Delivery: 7-9 months after receipt of order PROVIDING:
A. Customer supplied chassis (if applicable) is received a minimum of sixty (60) days before scheduled
delivery.
B. Customer approval drawings are returned by requested date.
C. Customer supplied accessories are received by date necessary for compliance with scheduled delivery.
D. Customer expectations are accurately captured prior to major components being ordered (body,
chassis) and line set date. Unexpected additions or changes made after this time or at a customer
inspection will delay the delivery of the vehicle.
Estimated Delivery is based on information at time of quote and is subject to change.
Altec reserves the right to change suppliers in order to meet customer delivery requirements, unless
specifically identified, by the customer, during the quote and or ordering process.

3

This quotation is valid until #EXPIRE_DATE#. After this date, please contact Altec Industries, Inc. for a
possible extension.

4

F.O.B. - Customer Site

5

Interest charge of 1/2% per month to be added for late payment.

6

FINANCING AVAILABLE: Please contact Altec Capital at (888) 408-8148 or email [email protected] for
more information.

7

Price does not reflect any local, state or Federal Excise Taxes (F.E.T). The quote also does not reflect any
local title or licensing fees. All appropriate taxes will be added to the final price in accordance with
regulations in effect at time of invoicing.

8

Changes made to this order may affect whether or not this vehicle is subject to F.E.T. A review will be
made at the time of invoicing and any applicable F.E.T. will be added to the invoice amount.

9

Any payment made by a credit card may be subject to a surcharge fee.

10

Altec Standard Warranty:
One (1) year parts warranty.
One (1) year labor warranty.
Ninety (90) days warranty for travel charges.
Warranty on structural integrity of the following major components is to be warranted for so long as the
initial purchaser owns the product: Booms, boom articulation links, hydraulic cylinder structures, outrigger
weldments, pedestals, subbases and turntables.
Altec is to supply a self-directed, computer based training (CBT) program. This program will provide basic
instruction in the safe operation of this aerial device. This program will also include and explain ANSI and
OSHA requirements related to the proper use and operation of this unit.
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 8 of 10

Page 48 of 75

Quote Number:

1853041 - 1

Altec, Inc.

Altec offers its standard limited warranty with the Altec supplied components which make up the Altec Unit
and its installation, but expressly disclaims any and all warranties, liabilities, and responsibilities, including
any implied warranties of fitness for a particular purpose and merchantability, for any customer supplied
parts
Altec designs and manufactures to applicable Federal Motor Vehicle Safety and DOT standards
11

Altec Extended Warranty Option:
An Altec Extended Warranty is an extension of Altec's Limited Warranty and protects you from the repair
cost associated with defects of materials and workmanship after the standard Limited Warranty expires.
Altec offers many types of coverages and coverage packages. Ask your Altec account manager for details.
Quotes are available upon request.

12

After the initial warranty period, Altec Industries, Inc. offers mobile service units, in-shop service and same
day parts shipments on most parts from service locations nationwide at an additional competitive labor and
parts rate. Call 877-GO-ALTEC for all of your Parts and Service needs.

13

Trade-in offer is conditional upon equipment being maintained to DOT (Department of Transportation)
operating and safety standards and remaining in compliance of DOT until arrival at an Altec Facility. This
will include, but is not limited to engine, tires, lights, brakes, glass, etc. All equipment, i.e., jibs, winches,
pintle hooks, trailer connectors, etc., are to remain with unit unless otherwise agreed upon in writing by
both parties. ALTEC Industries reserves the right to re-negotiate its trade-in offer if these conditions are
not met.
All reasonable and necessary expenses required of ALTEC Industries to execute transportation of the
trade-in will be invoiced to the customer for payment if these conditions are not met to maintain DOT
standards.
Customer may exercise the option to rescind this agreement in writing within sixty (60) days after receipt of
purchase order. After that time ALTEC Industries will expect receipt of trade-in vehicle upon delivery of
new equipment as part of the terms of the purchase order unless other arrangements have been made.

14

The final fully loaded weight of the truck and structural ratings of the hitch assembly may reduce the towing
capacity and the vertical load capacity of the finished truck. These capacities may not match the ratings of
the chassis or hitch.

15

Altec takes pride in offering solutions that provide a safer work environment for our customers. In an effort
to focus on safety, we would encourage you to consider the following items:
Outrigger pads (When Applicable)
Fall Protection System
Fire extinguisher/DOT kit
Platform Liner (When Applicable)
Altec Sentry Training
Wheel Chocks
The aforementioned equipment can be offered in our new equipment quotations. If you find that any of
these items have not been listed as priced options with an item number in the body of your quotation and
are required by your company, we would encourage you to contact your Altec Account Manager and have
an updated quote version sent to you. These options must be listed with an item number in the quotation
for them to be supplied by Altec.

16

Altec values your data privacy. The Altec Family of Companies (including Altec, Inc., and it's subsidiaries)
We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 9 of 10

Page 49 of 75

Quote Number:

1853041 - 1

Altec, Inc.

may collect telematics data from the equipment you own. Please review Altec's Equipment Data Privacy
Notice on www.altec.com for more information. By purchasing equipment from Altec, you consent to Altec's
right to collect and use such data.
17

RECOMMENDED OPTIONS AND ACCESSORIES: These options are not included in the quote total price.
Selected options will change the quote total. Any options added after initial order will be re-quoted.

We Wish To Thank You For Giving Us The Pleasure
And Opportunity of Serving You
UTILITY EQUIPMENT AND BODIES SINCE 1929

Page 10 of 10

Page 50 of 75

Quote Number:
Opportunity Number:
Sourcewell Contract #:
Date:

Altec Industries, Inc.
Quoted for: Town of Front Royal (VA)
Altec Account Manager: Luke Mansfield

REFERENCE ALTEC MODEL
AT41M

Articulating Telescopic Aerial Device with Material Handling Insulated, 41'

1853041
2516276611
0421-ALT
5/5/2026

Sourcewell
Price
$221,241

SOURCEWELL OPTIONS ON CONTRACT (Unit)

(A.)

1
2
3
4

(A1.) SOURCEWELL OPTIONS ON CONTRACT (General)
1
2
3
4
5
6
7
8
9
10

(B.)

SOURCEWELL OPTIONS TOTAL:

$221,241

OPEN MARKET OPTIONS TOTAL:

$0
$0
-$1,254
$0
$0
$0
-$6,733
-$9,416
-$17,403

OPEN MARKET ITEMS (Customer Requested)
1
UNIT
2 UNIT & HYDRAULIC ACC
3
BODY
Stock Body
4 BODY & CHASSIS ACC
5
ELECTRICAL
6
FINISHING
7
CHASSIS
2026 F600 4x4 Auto
8
OTHER
Altec Model Year Price Adjustment

SUB-TOTAL FOR UNIT/BODY/CHASSIS:
Delivery to Customer:
TOTAL FOR UNIT/BODY/CHASSIS:

$203,838.00
$1,074.00
$204,912.00

ADDITIONAL ITEMS (items are not included in total above)

(C.)
1
2
3
4

**Pricing valid for 45 days**
NOTES
PRICING: Altec will make every effort to honor this quotation, subject to the following provisions. Prices for equipment with production
start dates 12 months and beyond are considered budgetary due to potential cost inflation, market volatility, and tariff implications.
These prices will be reviewed based on market conditions and confirmed closer to the production date. Quotes and orders with chassis
model years beyond the current open order bank are estimates only. Altec's turn-key pricing is subject to change based on chassis
pricing received from the OEM. Chassis model year, specifications, and price will be reviewed and confirmed when specific model year
information becomes available from the OEM, and any chassis price difference, including adjustments for tariffs, will be passed through
to the customer.
PAINT COLOR: White to match chassis, unless otherwise specified
WARRANTY: Standard Altec Warranty for Aerials and Derricks - One (1) year parts warranty One (1) year labor warranty Ninety (90)
TO ORDER: To order, please contact the Altec Account Manager listed above.
CHASSIS: Per Altec Commercial Standard
DELIVERY: TBD Based on availability, FOB Customer Location
TERMS: Net 30 days
BEST VALUE: Altec boasts the following "Best Value" features: Altec ISO Grip Controls for Extra Protection, Only Lifetime Warranty on
Structural Components in Industry, Largest Service Network in Industry (Domestic and Overseas), Altec SENTRY Web/CD Based
Training, Dedicated/Direct Gov't Sales Manager, In-Service Training with Every Order.
TRADE-IN: Please ask your Altec Account Manager for more information
Town of Front Royal (VA) - AT41M F600 4x4 Auto - SW - 1853041

Page 51 of 75

COUNCIL REGULAR WORK SESSION
AGENDA STATEMENT
Meeting Date: May 11, 2026

Item# 5A

Agenda Item: Zoning text amendments to Town Code §175-3 – Definitions to define data centers and town code
§175-64 industrial employment district (i-2) to add data centers with performance standards by special use
permit.

Summary: The Planning Commission held two work sessions to review the proposed text amendment which
adds the definitions of Data Center with performance standards and requirements for impact analysis
submissions to the Town. Planning Commission held a public hearing on September 17, 2025, and recommended
approval.
At the October 6th Town Council Work Session, it was recommended to inquire about contracting legal services
to review the draft amendments for compliance with Virginia Code, industry standards, and zoning practices
for the health, safety, and welfare of the community.
Recent Virginia General Assembly actions may require the current draft to be reviewed and amended by the
Planning Commission.

Budget/Funding: N/A

Staff Recommendation: Council is to consider advertising the draft amendments for a public hearing at a future
date or refer the item back to the Planning Commission for further review.

Page 52 of 75

Town of Front Royal, Virginia
Planning Commission Regular Meeting Agenda

Agenda Item: Zoning Text Amendment # 2500345
MEETING DATE: September 17, 2025
SUMMARY: For the public necessity, convenience, general welfare, or good zoning practice, Zoning Text
Amendments to Town Code §175-3 – Definitions to define Data Centers and Town Code §175-64 Industrial
Employment District (I-2) to add Data Centers with performance standards by Special Use Permit, and
establish §175-74 Data Center Impact Analysis requirements.
STAFF RECOMMENDATION: Staff recommends approval.
DRAFT MOTION: “For the purposes of good zoning practice and in accordance with Town Code §1751(B), I move that the Planning Commission forward a recommendation of approval to the Town Council
to approve Zoning Text Amendments to Town Code §175-3 – Definitions to define Data Centers, Town Code
§175-64 Industrial Employment District (I-2) to revise the I-2 statement of intent and to add Data Centers with
performance standards by Special Use Permit, and establish §175-74 Data Center Impact Analysis
requirements.
“I move that the Planning Commission keep the public hearing open to _________________. “
“I move that the Planning Commission forward a recommendation of denial to the Town Council for
Zoning Text Amendment #2500345.”
NOTE: This is only a draft motion. Alternative motions are also welcome.

PLANNING COMMISSION ACTION:
Moved

Seconded

Marshner _______ Marrazzo _______ Neel _______ Brooks _______ Fedoryka _______

Page 53 of 75

Staff Report : Zoning Text Amendment 2500345
Background Information

Planning Commission (PC) has had two work sessions to discuss the
proposed Data Center text amendments to the I-2 Zoning District. This
amendment will provide a mechanism to restrict Data Centers as a land use
exclusively to the I-2 district and only permit them by Special Use Permit. This
ordinance was derived from extensive research into the lessons learned of
other jurisdictions and a thorough analysis by PC members.
Staff recommends approval to the Town Council

Code Sections Amended

An ordinance to amend Town Code §175-64 to revise the I-2 district statement
of intent, add Data Center specific performance standards to Town Code §17570 and establish §175-74 Data Center Impact Analysis requirements.

Page 54 of 75

AN ORDINANCE TO AMEND CHAPTER 175-74 OF THE FRONT ROYAL TOWN CODE
TO REVISE THE I-2 DISTRICT STATEMENT OF INTENT, ADD DATA CENTER SPECIFIC
PERFORMANCE STANDARDS TO 175-70 AND ESTABLISH 175-74 DATA CENTER
IMPACT ANALYSIS REQUIREMENTS.
175-3 – DEFINITIONS
For the purpose of this chapter, certain words and terms are herein defined as follows:
ANSI S1.4 - A standard that specifies the performance requirements for sound level meters, including different
types of meters used for measuring sound levels in various environments.

T

BEST MANAGEMENT PRACTICES (BMP) - Proven and repeatable practices and workflows that represent the most
effective and efficient ways to achieve organizational goals, maintain compliance, and enhance overall
performance.

AF

CORRELATED COLOR TEMPERATURE (CCT) - It is essentially a gauge of how yellow or blue the color of light
emitted from a light bulb appears. It’s measured in the Kelvin.
DATA CENTER - A use where digital information is processed, transferred, and/ or stored, occupying 10,000 square
feet or more, where the majority of space is occupied by computers, servers, telecommunications and related
equipment (including supporting equipment).

R

DATA CENTER CAMPUS (CAMPUS) - Land occupied and maintained by Data Center.

D

DECIBEL AUDIBLE (dB(A)) - Weighted power measurement for noise that filters high and low frequencies not of
concern to human hearing.
DECIBELS RELATIVE TO THE CARRIER (dB(C)) - A measurement that expresses the power ratio of a noise signal to a
carrier signal in decibels. It indicates how much weaker or stronger the noise is compared to the carrier, with
positive values showing stronger noise and negative values indicating weaker noise.
EMERGENCY MEDICAL SERVICES (EMS) - The immediate medical response and pre-hospital care provided by
trained professionals (such as paramedics and emergency medical technicians) to individuals experiencing acute
illness or injury, typically in emergency situations like accidents, cardiac arrest, trauma, or other medical crises.
FOOT CANDLES (fc) - A unit of measurement for illuminance, which indicates how much light is received on a
surface. Specifically, one foot-candle equals one lumen per square foot.
g - Refers to the unit of acceleration due to gravity, which is approximately 9.8 m/s². It is used to measure the
magnitude of vibration, with higher g values indicating greater levels of acceleration and potential impact.
LARGE INDUSTRIAL FACILITY UTILITY USER: Refers to a business or organization that consumes or discharges a
significant volume of utilities such as electricity, natural gas, or water due to large-scale industrial operations.

Page 1 of 21

Page 55 of 75

LUMINOUS EFFICACY (lm/w): Luminous Efficacy relates the luminous flux produced by a light source and the
actual luminous flux emitted, i.e. how much light a light source is capable of producing and how much light it
actually emits.
POWER USE EFFECTIVENESS (PUE): A metric used to measure the energy efficiency of a data center. It compares
the total amount of power used by the facility to the power used specifically by the computing equipment (like
servers, storage, and networking devices).
SMALL DATA CENTER: A use where digital information is processed, transferred, and or stored, occupying less than
10,000 square feet, where the majority of space is occupied by computers, servers, telecommunications and
related equipment (including supporting equipment).

175-64 STATEMENT OF INTENT (I-2)
The I-2 Industrial Employment District is designed to:

T

INDUSTRIAL EMPLOYMENT DISTRICT (I-2)

Enable the establishment of industrial, and employment uses and structures in appropriate locations of
the town.

B.

Prevent land or structures from being used in a manner so as to create any dangerous, injurious,
noxious or otherwise objectionable risk of fire, explosion, radioactivity or other hazardous condition;
noise or vibration, smoke, dust, odor or other form of air pollution; electrical or other disturbance,
glare or heat; liquid or solid waste; or other condition that would detract from the residential and
commercial desirability of the adjoining areas.

C.

Provide controls and standards for the establishment of industrial, and employment uses and
structures in keeping with the purposes of this Article and the Front Royal Comprehensive Plan.

D.

Establish standards and guidelines for the construction, use and operation of Data Centers.

D

R

AF

A.

175-65 USE REGULATIONS (I-2)
A.

Subject to the standards and requirements set forth in this Chapter, except as prohibited or restricted by
separate restrictions of record that may pertain to property within the I-2 District, the following uses of land
and buildings are permitted by-right in the I-2 District:

RESIDENTIAL:
Caretaker quarters.
COMMERCIAL:
Automobile and truck sales lots and leasing agencies, in accordance with Section 175-44.E.
Automobile garage (auto repair).
Automobile service stations (gas stations).
Business Offices.
Coal and wood yards, lumberyards and feed/seed stores.
Commuter parking facilities.

Page 2 of 21

Page 56 of 75

Contractor's offices, display rooms and storage.
Furniture stores.
Lumber and building supply.
Professional Offices.
Technology Business.
Veterinary hospitals.
INDUSTRIAL:
Distribution facilities.
Light Manufacturing.
Woodworking and upholstery shop.
Wholesale.
ORGANIZATIONAL:

T

Laboratory, pharmaceutical and/or medical.
Schools.

AF

MISCELLANEOUS:
Accessory uses, structures and buildings.
Home occupations.
Open Space.
Public facilities.

Public utilities.

R

Public parks and playgrounds.

Signs, as set forth in Section 175-106.

D

Special childcare services.

Such other uses as determined similar to one (1) or more enumerated uses by the Zoning Administrator.
B.

The following uses are permitted within the I-2 District only by approval of a special use permit, except as
prohibited or restricted by separate restrictions of record that may pertain to property within the I-2 District:

RESIDENTIAL:
COMMERCIAL:
Airport (including heliports).
Assembly Halls.
Barber and beauty shops.
Catering Services.
Clubs.
Daycare and daycare facilities.
Kennels.
Recreation facility, commercial.

Page 3 of 21

Page 57 of 75

Restaurant, including drive-in restaurants.
Retail Stores.
INDUSTRIAL:
Automobile Graveyard.
Data Center (subject to the supplemental provisions prescribed in Section 175-70.J & 175-74).
Hazardous Material Storage.
Heavy Manufacturing.
Medium Manufacturing.
Scrap metal processing.
ORGANIZATIONAL:
MISCELLANEOUS:

T

Any use permitted under Section 175-65.A, or specifically listed above under this subsection, that proposes
to occupy a building or structure that exceeds the height requirements of Section 175-67, subject to the
requirements of Section 175-136. Additional heights approved by a special use permit shall be required to
increase the required setback and yard area requirements by an equivalent distance from each property line.

AF

Communications Towers and cable television facilities, with wireless telephone (cell phone) communications
tower subject to the supplemental provisions prescribed in Section 175-110.4.
Conservation Areas.
Mini-warehouses.
Parking Structures.

R

(Ord. of 6-26-00; Ord. of 4-14-03; Ord. of 7-25-05; Ord. of 9-26-05; Ord. of 7-28-08; Ord. of 2-28-11; Ord of 6-2215; Ord. of 3-28-16)

175-66 AREA REGULATIONS (I-2)

Minimum lot size: Twenty thousand (20,000) square feet.

B.

Minimum lot width: Eighty (80) feet.

C.

Minimum district size: Ten (10) acres.

D

A.

175-67 MAXIMUM HEIGHT OF BUILDINGS (I-2)
A.

All buildings/structures: Seventy-five (75) feet, except as provided for in Section 175-65.B.

B.

Exemptions to height requirements:
1.

Chimneys and flues.

2.

Cooling towers.

3.

Flagpoles.

4.

Radio and communications towers.

5.

Parapet walls up to four (4) feet above the height of the building on which the wall rests.

6.

Water towers.

Page 4 of 21

Page 58 of 75

7.

Elevator towers.

175-68 MINIMUM YARD DIMENSIONS (I-2)

B.

All structures:
1.

Front: Twenty-five (25) feet.

2.

Side: Ten (10) feet.

3.

Rear: Zero (0).

4.

Corner side: Twenty-five (25) feet.

Transitional requirements, when adjoining a residential district:
1.

Side: Forty (40) feet.

2.

Rear: Forty (40) feet.

3.

All transitional yards shall be landscaped in accordance with Section 148-44.

175-69 LOT COVERAGE (I-2)

T

A.

Maximum building coverage: Fifty percent (50%).

B.

Maximum impervious surface coverage: Seventy-five percent (75%).

AF

A.

175-70 PERFORMANCE STANDARDS (I-2)

The following performance standards shall apply to all uses within the I-2 Industrial Employment District:

R

Vibration:
1.

No continuous, frequent or repetitive vibrations shall be produced which are discernible to a
person of normal sensitivities, without instruments, on land that is not zoned for industrial uses.

2.

Vibrations from temporary construction and vehicles leaving the property (such as trucks or
trains) are excluded. Vibrations from on-site equipment or vehicles that remain primarily on-site
are included.

3.

Vibrations of no more than five (5) minutes in any one (1) day between the hours of 7:00 a.m.
and 7:00 p.m. shall not be deemed continuous, frequent or repetitive.

D

A.

B.

Glare: Any operation or activity producing intense light or glare shall be performed in such a manner as
not to create a glare effect across lot lines. Direct illumination from any source shall be screened from
adjoining properties.

C.

Heat:

D.

1.

Heat from an industrial use shall not at any time cause a temperature increase in the air on any
adjacent property in excess of ten degrees Fahrenheit (10° F.).

2.

Heat from an industrial use shall not at any time cause a temperature increase in a stream,
wetland, lake or any other body of water, at or beyond the property line of the lot on which it is
located, that would have an adverse effect on any aquatic life.

Liquid or Solid Wastes:

Page 5 of 21

Page 59 of 75

H.

There shall be no accumulation outdoors of solid wastes conducive to the breeding of rodents or
insects.

3.

All discharges into any public sewer shall comply with the provisions of Section 134-2 et seq.

Smoke and Particulate Matter:
1.

Open storage and open processing operations, including on-site transportation movements
which are the source of windborne dust or other particulate matter or which involve dust or
other particulate air contaminant generating equipment (such as used in paint spraying, grain
handling, sand or gravel processing or sandblasting) shall be conducted so that dust and other
particulate air contaminants are not transported in visible quantities across the boundary line of
the tract on which the industrial use is located.

2.

All industrial uses shall comply with state and federal air pollution control regulations.

Toxic and Hazardous Materials:
All toxic and hazardous materials used in industrial operations shall be registered with the Front
Royal Fire Department for purposes of safety.

2.

Activities involving the storage or use of materials or products which decompose by detonation
shall be registered with the Front Royal Fire Department.

3.

Explosives shall be stored, used and manufactured in accordance with applicable state and
federal regulations.

T

1.

AF

G.

2.

Odor:
1.

No continuous, frequent or repetitive emission of odors or odor-causing substances of such
intensity and character as to be detrimental to the health and welfare of the public or
neighboring landowners or to interfere with the comfort of the public or neighboring landowners
at or beyond the property line shall be permitted. Any such odor or odor causing activity or
substance shall be removed, stopped or so modified as to remove the odor.

2.

An odor which is evident no more than once in any one (1) day for a period not exceeding five (5)
minutes shall not be deemed as continuous, frequent or repetitive within the meaning of these
regulations.

R

F.

No industrial use shall result in the discharge of liquid or solid waste into any public sewer,
private sewage system, public waters or into the ground except in compliance with applicable
federal, state or local laws governing such discharge.

Noise:

D

E.

1.

1.

No industrial activity shall generate noise that tends to have an annoying or disruptive effect
upon uses located beyond the property boundary.

2.

Where technical evidence of violation is warranted, sound levels shall be measured at locations
specified in Section 175-71 with a sound level meter and associated octave band filter,
manufactured in accordance with the American Standards Association. Measurements shall be
made using the flat network of the sound level meter. No sound pressure level shall exceed the
decibel levels in the octave bands shown herein.

3.

Maximum permitted sound levels (in decibels):

Page 6 of 21

Page 60 of 75

Octave Band Cycles
Per Second
0 to 75
75 to 150
150 to 300
300 to 600
600 to 1200
1200 to 2400
2400 to 4800
Above 4800

Noise resulting from temporary construction activity between the hours of 7:00 a.m. and 7:00
p.m. shall be exempt from this section.

Screening:

Except where otherwise specifically approved in the Town Code, permitted uses shall be
conducted wholly within a completely enclosed building.

2.

Outdoor storage, outdoor display or outdoor sale of goods shall only be permitted when each of
the following standards are met:

AF

1.

Outdoor storage, outdoor display, or outdoor sale of goods shall be used in direct
association with the primary use or uses of the property.

b.

Outdoor storage, outdoor display and/or outdoor sales shall be screened to obstruct view
from any adjacent public street. A screen may consist of a building, solid masonry wall,
uniformly painted solid board fence or landscaping. The height of the screening shall be six
feet (6') feet unless an alternative height is approved by the Planning Commission during
the review of a site plan.

R

a.

3.

D

I.

72
67
59
52
46
41
38
35

T

4.

Maximum Permitted
Sound Level
in Decibels

The following types of outdoor display and/or outdoor sales shall be exempt from the
requirements of Section 175-70.I.2.b:
a.

Motor vehicles.

b.

Power operated machines designed for outdoor labor, such as farming, construction or
lawn maintenance, as well as large equipment, products, and materials designed to be kept
outdoors.

c.

Plants and other landscaping products typically sold with plants.

d.

Temporary or seasonal activities, such as but not limited to, peddlers and itinerant
merchants that have obtained approval from the Town.

e.

Pre-manufactured buildings.

f.

Vending machines.

g.

General products, goods, merchandise, and/or materials, provided that: (i) no more than
two hundred (200) square feet of area is used, and (ii) outdoor display and/or sales are
restricted from the evening and night hours from 8:00 p.m. to 5:00 a.m., except that

Page 7 of 21

Page 61 of 75

general products, goods, merchandise, and/or materials may be kept outdoors if located
under a roofed structure.
4.

All sites and parking areas shall be landscaped in accordance with the provisions of Sections 14846, 148-47 and 148-48.

5.

Automobile graveyards and junkyards, including those in existence at the time of the adoption of
this chapter, shall completely screen, on any side open to view from a public road, the operation
or use by a solid masonry wall, a uniformly-colored solid fence or dense evergreen plantings at
least six (6) feet in height at the time of planting.

In addition to performance standards A through I, the following performance standards shall apply only to Data
Center use within the Industrial Employment District.
Data Center Performance Standards:
As a “Large Industrial Facility Utility User” data centers shall be subject to application
requirements and performance standards intended to mitigate adverse impacts on adjacent
properties, infrastructure, and natural resources. These standards shall address, at a minimum,
operational noise, visual buffering, stormwater management, energy infrastructure, and
emergency power systems. Whenever possible, innovative resource (power, water, etc.)
protection implantations are encouraged. Application requirements will include:

T

1.

a.

Data Center Utility Impact Analysis.

b.

Data Center Physical Impact Analysis

c.

Data Center Environmental Impact Analysis.

AF

J.

Data Center Impact Analysis requirements can be found in section 175-74.
Minimum Setback Requirements:

Adjacent to residential zoning districts: minimum setbacks shall be at least 200 feet.

b.

Adjacent to Planned Neighborhood Development (PND) zoning districts: minimum setbacks
shall be at least 150 feet.

c.

Adjacent to commercial and industrial zoning districts: minimum setbacks shall be at least
25 feet.

R

a.

D

2.

3.

i.

Adjacent to public streets, railways and other rights-of-way: minimum setbacks shall
be at least 40 feet.

ii.

Adjacent to Agriculture and Open Space Preservation District (A1) shall be no less than
100 ft.

iii.

Setbacks for property that adjoins the corporate limits of the town shall have a
setback of no less than 200 ft.

iv.

Between buildings: Within a common scheme of development where individual lots
or building sites are to be sited, the minimum setback between buildings on adjacent
lots or building sites shall be at least 25 feet.

Perimeter Buffers:
a.

All buffers shall be inclusive of required setbacks.

b.

Buffer yard plantings shall be designed to minimize visual impacts from adjacent public
streets and properties not in common ownership. Notwithstanding the requirements of this
section, use of natural topography and preservation of existing vegetation, supplemented
by new vegetation and security fencing. All new trees shall be at least 6 feet tall at time of
planting and achieve a height of at least 25 feet at maturity.

Page 8 of 21

Page 62 of 75

c.

a.

A minimum of thirty (30) percent open space (permeable surface area) shall be maintained
for each campus or contiguous group of parcels in common ownership within the lot,
including undeveloped land, wetlands, steep slopes, stormwater best management practice
features, open areas, landscape buffers, and land used primarily for resource protection or
recreational purposes.

b.

The on-site open space requirement may be reduced to 20% on a parcel where all
stormwater best management practices are designed where all volume and nutrient
treatment occurs on site without the purchase of offsite nutrient credits.

Noise Standards

a.

AF

T

Technical Note: Unlike other sources of noise, data centers generate a continuous,
mechanical sound profile primarily from industrial-scale cooling systems, power
infrastructure, and ventilation equipment which may persist 24 hours a day.
Because this noise is largely constant and not intermittent, it presents unique
challenges to nearby residential areas and requires separate regulation from most
general noise provisions. These standards aim to protect public health, residential
quality of life, and nighttime peace while allowing for the lawful operation of data
center facilities.

Noise standards are measured in bands and across total audible spectrum. Noise is
measured prior to construction and the post construction operational phase of data center.
i.

Low-frequency core audio band: Sound in the range of 10 Hz to 250 Hz, dB(C).

ii.

High-frequency core audio band: Sound in the range of 2,000 Hz to 8,000 Hz, dB(A).

R

5.

Open Spaces

Note: Mid frequency core audio band is not specified above in i or ii since it doesn’t
typically create tonal or vibration-related issues. It is, however, captured within both
A-weighted and C-weighted measurements specified later in this section. The
specified high and low frequencies are the most common culprits in nuisance or
environmental complaints, especially from data centers (cooling fans, HVAC, etc.)

D

4.

A perimeter buffer shall be established and maintained with a minimum width of twentyfive feet along the perimeter of each Data Center Campus. In addition, additional plantings
within the setback area but spread outside of the separately landscaped perimeter buffer
shall be installed and maintained by the campus owner.

iii.

Overall level and total noise in dB(A): Sound across 10 Hz to 20000 Hz.

iv.

Overall level and total noise in dB(C): Sound across 10 Hz to 20000 Hz

Note: dB(A): A-weighted decibel scale (emphasizes frequencies heard by humans) and
dB(C): C-weighted decibel scale (captures low-frequency noise).
v.
Any noise which emanates from operation or other activity associated with any data
center or research, development, or light manufacturing facility, or their accessory
uses shall be limited to a “Equivalent Continuous Sound Level (LEQ)” in A-weighted
decibels of 59 dB(A) (+/- 1.5 dB) and C- weighted decibels 65 dB(C) (+/- 1.5 dB) during
the day (7:00 a.m. until 9:00pm) and 52 dB(A) (+/- 1.5 dB) and 58 dB(C) (+/- 1.5 dB)
during the night (9:00pm through 7:00 a.m.). LEQ shall be measured over a minimum
15-minute interval for both daytime (7:00 a.m. to 9:00 p.m.) and nighttime (9:00 p.m.
to 7:00 a.m.) periods. If the total spectrum measurement yields a 15dB difference
between dB(A) and dB(C), additional analysis to identify any spectral peaks is
required.

Page 9 of 21

Page 63 of 75

vi.

Measurements shall be taken at the campus boundaries, using calibrated sound level
meters conforming to ANSI S1.4 Type 1 or Type 2 standards, with the meter set to
“Slow” response and utilizing A-weighting (dB(A)) and C-weighting (dB(C)) as
appropriate. Environmental noise levels shall be tested prior to construction and in
the post construction operational phase.

vii.

A differential analysis across 10 Hz to 8000 Hz band utilizing dB(A) and dB(C) total
band measurements shall be conducted. That differential shall not exceed:
(1)

≤ 15dB +/- 1.5 dB Daytime

(2)

≤ 20dB +/- 1.5 dB Nighttime

viii. Utilizing dB(A) and dB(C) total band measurements, a 1/3 Octave Band Analysis. shall
not detect tonal components and frequency-specific noise:
A 1/3-octave band has a sound pressure level ≥ 5 dB higher than the levels in
the adjacent bands (on either side).

(2)

A narrowband spectral peak that stands out significantly from the background
spectrum and can be clearly heard as a hum, whine, buzz, or tone.

Frequency-Specific Adjustments

If a noise source contains tonal components (i.e., pure tones) in the low- or
high-frequency range, the following penalties apply:

AF

(1)

T

ix.

(1)

(a) +5 dB penalty if the noise has distinct tonal components at 250 Hz or less
(e.g., industrial fans).
(b) +3 dB penalty if the noise has tonal components above 250Hz (e.g.,
squeals).

x.

R

(c) These measurement penalties are added to the measured A-weighted
Equivalent Continuous Sound Level (LEQ) value for analysis.
Sound measurements equipment standards:
Measurements must be taken using calibrated sound level meters complying
with ANSI S1.4 Type 1 or Type 2 standards:

D

(1)

(a) At the campus boundary.
(b) With the meter set to “Slow” response.
(c) With A-weighting and C-weighting applied for respective limits.
(d) Wind screening, weather condition controls, and height of measurement
mic (e.g., 1.5 m above ground) shall be used for measurement equipment
set-up.

xi.

xii.

Sound Exemptions would include:
(1)

Construction work (governed by existing noise ordinance).

(2)

Emergency operations.

Generator testing:
(1)

Generator testing shall be conducted between 7:00 a.m. until 7:00 p.m. unless
testing at a time outside of this range is required by the Department of
Environmental Quality.

Page 10 of 21

Page 64 of 75

(2)

The sound study shall be specific to the proposed site layout and building type,
scale, and height shown on the site plan and shall evaluate (i) the noise
conditions at the site prior to project development at set locations as
determined by the Town and (ii) provide model- predicted noise conditions
resulting from the proposed project post-development.

(3)

The sound study shall include recommendations for mitigation measures, and
which mitigation measures, if applicable, should be incorporated into
conditions of issuance of site plan approval, or to issuance of building permit(s).

xiii. Post-development noise.
Noise conditions at and/or within the lot will be evaluated and compared to all
local code requirements within sixty (60) days after the issuance of the/a
occupancy permit for each phase and/or campus facility, and annually
thereafter for a period of ten (10) years. Said evaluations shall be conducted by
the campus operator at a time(s) generally known for peak data center cooling
operations.

(2)

Backup generators shall be housed in an interior acoustically controlled
structure for noise abatement.

T

(1)

xv.

Any noise testing that reveals anomalous or out-of-specification results may
necessitate additional analysis, further testing, and/or the implementation of
appropriate mitigation measures to ensure compliance with applicable standards and
performance requirements.

R

Quantitative Vibration Limits.
a.

No use, operation or activity shall cause or create earth borne vibrations in violation of the
below vibration standards as measured at the Data Center campus boundary.

b.

All measurements shall be taken prior to construction and post construction operational
phase for comparative analysis and baseline vibration establishment.

D

6.

AF

xiv. Where no residential or noise-sensitive receptors are present or reasonably
foreseeable within 1000 feet of a data center campus, and where site-specific
conditions mitigate off-site sound transmission, noise limits may be relaxed on a caseby-case basis, subject to acoustic assessment and review.

c.

Continuous Vibration (Steady-State Sources):

i.

The peak particle acceleration shall not exceed the baseline measurement:
(1)

0.002 g for frequencies ≤ 50 Hz.

(2)

0.001 g for frequencies > 50 Hz.

(3)

Impulse or Intermittent Vibration:
(a) For single events occurring less than once every 5 minutes, vibration levels
may not exceed 0.01 g peak acceleration.

d.

e.

Measurement Protocol, all measurements shall be:
i.

Taken at the campus boundary line adjacent to data center.

ii.

Conducted using ANSI S2.47-1990 or ISO 2631 compliant vibration meters.

iii.

Recorded as peak acceleration (g), with frequency analysis.

Measurements shall be made during the loudest expected operational periods, including
emergency generator testing, peak cooling demand, or routine maintenance cycles.

Page 11 of 21

Page 65 of 75

f.

i.

Temporary construction-related vibration is exempt, provided it complies with
applicable construction noise and hours-of-operation rules.

ii.

Where no residential or vibration-sensitive receptors are present or reasonably
foreseeable within 1000 feet of a data center campus, and where site-specific
conditions mitigate off-site vibration transmission, vibration limits may be relaxed on
a case-by-case basis, subject to vibration assessment and review.

Outdoor Lighting Standards.
a.

Lighting standards shall apply to all new data centers in Front Royal, as well as expansions
or renovations involving exterior lighting.

b.

A photometric Lighting Plan must accompany site/subdivision plan or building permit
applications, showing:

ii.

Full manufacturer's specs (cutoff, wattage, CCT, shielding).

iii.

Calculated illuminance (fc) over the site and at all campus property lines.

iv.

Light trespass values extending to adjacent residential or commercial zones.

T

Fixture locations & mounting heights.

AF

Fixture Requirements.
i.

Fixtures ≥ 3,000 lumens must be full-cutoff, horizontal, and shielded to avoid upward
glare.

ii.

Private security lighting is allowed if motion-activated and ≤30 minutes per activation.

iii.

Mounting Heights.

iv.

Pole lights: Max 25 ft in industrial zones.

v.

Wall-mounted lights: Max 20 ft above finished grade.

vi.

Color Temperature & Efficiency.

vii.

Correlated color temperature (CCT) ≤ 3,000 K.

R

c.

i.

D

7.

Exemptions:

viii. Minimum efficacy 110 lm/W.
ix.

d.

e.

LED or energy-efficient equivalent mandatory.

Illuminance Limits.
i.

Entries/loading zones: ≤ 10 fc.

ii.

Parking areas: ≤ 5 fc average.

iii.

Drive aisles/internal roads: ≤ 3 fc.

iv.

Perimeter fencing: ≤ 1 fc.

v.

At campus property lines: ≤ 0.2 fc (adjacent residential); ≤ 0.5 fc (adjacent
non-residential).

Controls & Dim-Down Requirements.
i.

Dimming ≥ 50% within 30 minutes of facility close (unless lighting supports active
operations).

ii.

Photocells or timeclocks required.

Page 12 of 21

Page 66 of 75

iii.
f.

g.

Prohibitions.
i.

No exposed floodlights, cobra heads, uplighting, colored or flashing lights (unless
emergency).

ii.

No light trespass or glare onto surrounding public roads.

iii.

Exceptions (Special Exception Only)
Security lighting exceeding standard limits may be approved if:

10.

Motion-activated or timed.

(2)

Proved no glare or boundary trespass.

Prior to Certificate of Occupancy, the applicant must submit:
(1)

Field measurements from a lighting engineer, or

(2)

Engineer certificate attesting full compliance.

T

Water Cooling Standards.

No permitted or accessory use described in the underlying zoning district shall be permitted
to permanently utilize potable water for industrial cooling, including but not limited to a
data center cooling.

b.

Shall not apply to water requirements of domestic water (drinking water and sanitary
facilities for employees and occupants) and fire suppression standards.

c.

Temporary potable water for industrial cooling may be provided through a Water Service
Agreement approved by the Town Council to bridge initial water requirements while an
industrial reuse water cooling system is constructed.

d.

Where possible, the prioritization of cooling technologies that significantly reduce water
consumption (e.g., dry cooling, hybrid cooling, or air-cooled chillers) is encouraged.

e.

The cooling systems proposed shall reflect a good-faith effort to incorporate resourceefficient technologies.

R

AF

a.

D

9.

(1)

Compliance Verification.
i.

8.

Occupancy sensors in low-traffic/service areas.

Building Height Standards.
a.

The maximum height shall be no more than seventy-five (75) feet.

b.

The height limitation shall not apply to parapets, screening, spires, belfries, cupolas, roofmounted antennas or communications towers, air cooling ventilation equipment,
ventilators, or other appurtenances usually required to be placed on the roof level and not
intended for human occupancy, which shall be subject to the exception stated in Town
Code.

c.

A Special Exception may be permitted via the Special Use Permit process.

Building Size Standards.
a.

The maximum size of an individual building is 100,000 square feet. A special exception is
required to exceed this size. A special exception may be permitted via the Special Use
Permit process.

Page 13 of 21

Page 67 of 75

a.

Any building facade visible from adjacent properties or public streets shall incorporate a
differentiation that breaks the mass of the facade every 100 horizontal linear feet and no
less frequent than 3 times the average height of the building by changes in at least two of
the following design elements: building height, facade step-back or recesses (minimum 2
1/2 feet depth), fenestration, façade materials, pattern, texture, color, or use of accent
materials. All visible facades of a building must be consistent in terms of design, materials,
details, and treatment.

b.

Windows, doors, or similar fenestration design features such as faux windows must be
distributed horizontally and vertically across the façade and comprise a minimum of 15% of
each visible building façade. A green-wall treatment may be provided to meet up to half of
the required 15% area.

c.

The following elements shall be included in the building design:
A main entrance feature that is differentiated from the remainder of the façade.

iii.

High albedo or light-colored roof.

iii.

Enclosures for on-site generators.

iv.

Shrouds for any exhaust stacks.

AF

T

ii.

Building façade material requirements.
a.

Primary facade materials shall be limited to one or more of the following: tinted textured
masonry block, pre-cast concrete, tilt-up concrete panels, brick or stone veneer, glass (clear
or architectural panels), stucco and external insulation finish system that simulates a stucco
appearance, metal panel systems, structural metal siding, or smooth-faced concrete blocks.
All metal panels shall be fully engineered, architectural quality systems.

b.

Accent or trim building materials may include any of the primary facade materials, wood,
fiber cement, vinyl, or composite trim.

c.

Data Center Parking Standards.

D

12.

Differentiated Surfaces Standards.

R

11.

13.

14.

Parking.
a.

Small data center: 1 parking space/1,000 square feet.

b.

Large Data Center: 4 parking spaces for the first 4,000 square feet and a maximum of 1
parking space for every additional 6,000 square feet.

Additional testing and evaluations.
a.

Additional testing, analysis, or documentation may be required if the application or testing
contains ambiguities, inconsistencies, or lacks sufficient detail to assess compliance with
applicable standards.

Page 14 of 21

Page 68 of 75

175-71 LOCATIONS FOR DETERMINATION OF PERFORMANCE STANDARDS (I-2)
Measurements may be made at ground level or at habitable levels of buildings. Measurements shall be made at
the property boundary of the parcel where the industrial use is located.

175-72 ADMINISTRATION AND ENFORCEMENT OF PERFORMANCE STANDARDS (I-2)
Before a building permit or zoning permit shall be issued or construction commenced on any uses in this
district or a permit issued for a new use, the development plans shall be submitted to the Zoning
Administrator for review. Sufficient detail shall be provided on said plans to show compliance with the
substantive provisions of this chapter and compliance of the operations and processes to the performance
standards.

B.

Determinations of a violation shall be made pursuant to a test using either the senses of the Zoning
Administrator and a second municipal official/employee, or using equipment before notice of violation is
issued. The operator of an industrial use shall be given written notice of the time and place of the test and
given a reasonable opportunity to witness the test.

C.

The Zoning Administrator will notify landowners and business operators/tenants in writing of violations and
will then seek compliance. When notified of a violation, a landowner or tenant will have the opportunity to
demonstrate that the operation predates the application of this Article and is therefore a valid
nonconforming use. A finding of violation may be appealed to the Board of Zoning Appeals and then to the
courts.

D.

If a violation exists and the operator fails to take satisfactory action within two (2) weeks, the Zoning
Administrator shall take or cause to be taken such action as is appropriate to cause correction of such
violation. Failure to obey lawful orders concerning correction of such violation shall be punishable as
provided generally for violations in the Zoning Ordinance and in other laws or regulations affecting the case.

AF

T

A.

Parking space requirements:
1.

Industrial uses/manufacturing/distribution areas: One (1) space per employee and one (1) space for
every vehicle used on site, plus one (1) space per delivery/loading bay.

2.

Automobile garages: Two (2) spaces per service bay, or two (2) spaces for every three hundred sixty
(360) square feet. Every such facility shall have a minimum of three (3) spaces.

3.

Industrial uses/office component: One (1) space per three hundred (300) square feet of office area.

4.

Other uses not specifically enumerated: See Section 175-104.

D

A.

R

175-73 OFF-STREET PARKING AND LOADING (I-2)

B.

Location: Minimum setback for loading areas, driveways and parking: Five (5) feet from side and rear
property lines for parking areas with fewer than fifteen (15) spaces and five (5) feet from front property line
except where driveway entrance is located. All parking areas with fifteen (15) or more spaces shall meet the
requirements of Section 148-48.

C.

Loading space requirements:
1.

Number: One (1) space for first ten thousand (10,000) square feet of gross floor area, plus one (1)
space for each additional forty thousand (40,000) square feet or fraction thereof. For purposes of this
section, gross floor area shall include gross outdoor storage areas, covered or uncovered.

2.

Size of space: Minimum twelve (12) feet wide and fifty-five (55) feet in length, with a minimum clear
height of fifteen (15) feet.

Page 15 of 21

Page 69 of 75

175-74 Data Center Impact Analysis (I-2)
A.

Required Utility Impact Analysis (UIA)

Applicants must include a UIA certified by a Professional Engineer, containing:

2.

Electrical System Impacts.
a.

Projected peak & average load (MW).

b.

Power delivery plan from energy provider and impact shall include Backup Generator plans.

c.

Grid impact assessment: load studies, reliability analysis.

d.

Utility coordination documentation verifying capacity or required upgrades.

e.

Statement on cost/responsibility for infrastructure enhancements (e.g., private vs. public).

Water & Wastewater Assessment.
If applicable:

4.

5.

Daily and peak water usage (gallons/day).

b.

Cooling technology description (closed-loop, evaporative, reuse).

c.

Impact analysis on municipal water/wastewater systems.

d.

Water treatment plan for recycled water and other fluids.

e.

Correspondence from the Town of Front Royal/Public Works on capacity & fees.

R

AF

a.

Telecommunications Infrastructure.
a.

Summary of fiber/broadband needs and planned connectivity.

b.

Confirmation from providers regarding availability and capacity.

D

3.

T

1.

Sustainability & Efficiency Measures.
a.

Energy-efficiency features, including Power Use Effectiveness (PUE) targets.

b.

On-site renewable energy or offset strategies.

c.

Noise and heat mitigation strategies (e.g., screening, sound dampening, limited generator testing
hours).

Review Criteria.
a.

Adequate utility capacity and service availability.

b.

Whether infrastructure upgrades are funded by the developer, not taxpayers.

Page 16 of 21

Page 70 of 75

c.

Data Center Physical Impact Analysis.
Purpose
To ensure new data centers can integrate within the surrounding environment by evaluating their physical
impacts to include the following: 1) Noise; 2) Heat and Air Emissions; 3) Traffic and Access; 4) Visual and
Aesthetic; and 5) Vibration and Ground.
Applicants must submit a Physical Impact Analysis (PIA), prepared by a qualified engineer, architect, or
planner, as part of the zoning or site plan application. The PIA shall include the following:

3.

4.

Assessment of projected operational noise (e.g., cooling units, generators) at campus property
boundaries.

b.

Description of generator testing schedules and backup systems.

c.

Comparison to Town noise ordinance thresholds (in dBA).

d.

Mitigation measures: sound walls, enclosures, operational limits.

T

a.

AF

2.

Noise Impact Study.

Heat and Air Emissions Impact.
a.

Analysis of waste heat discharge from servers and HVAC systems.

b.

Evaluation of any thermal plumes or heat impacts on adjacent properties or ecosystems.

c.

Description of cooling system emissions (water vapor, particulates if using evaporative or diesel
systems).

d.

Heat mitigation strategies: green roofs, heat exchangers, landscaping, exhaust redirection.

R

1.

D

B.

Environmental/sustainability mitigations and community impacts (noise, heat, water use).

Traffic and Access Impact.
a.

Description of construction and operational traffic volumes, including truck deliveries, equipment
servicing, employee vehicles.

b.

Peak trip generation analysis using Institute of Transportation Engineers (ITE) standards (Land
Use 770: Data Center).

c.

Truck routing and site access plans.

d.

Traffic mitigation strategies: turn lanes, signalization (if warranted).

e.

Coordination with Town and VDOT if applicable.

Visual and Aesthetic Impact.
a.

Rendered site elevations or photomontages showing the facility from public roads and adjacent
uses.

Page 17 of 21

Page 71 of 75

7.

c.

Screening plans: landscaping, fencing, architectural treatments.

d.

Exterior lighting plan demonstrating compliance with dark sky standards.

Vibration and Ground Impact (if applicable).
a.

Analysis of potential vibration impacts from generators, cooling towers, or mechanical systems.

b.

Mitigation strategies: vibration dampers, equipment pads, sound-absorbing materials.

Land Use Compatibility Assessment.
a.

Assessment of how the facility aligns with adjacent zoning, comprehensive plan, and surrounding
land uses.

b.

Identification of sensitive uses nearby (residential, schools, parks, trails).

c.

Compatibility strategies: setbacks, buffering, hours of operation, community engagement.

T

6.

Analysis of height, scale, and bulk compared to surroundings.

Review Criteria.

AF

5.

b.

The Zoning Administrator and Planning Commission shall evaluate the PIA for:

9.

C.

b.

Adequacy of visual screening and building orientation.

c.

Impacts on neighboring land uses and mitigation adequacy.

d.

Safe and sufficient traffic circulation and site access.

e.

Compliance with sustainability and resiliency goals in the Town’s Comprehensive Plan.

R

Conformance with Town noise and lighting regulations.

D

8.

a.

Conditions of Approval.
a.

Approval of a zoning permit or site plan for a data center shall be contingent upon satisfactory
mitigation of any significant physical impacts identified in the PIA.

b.

Noise testing, generator operation logs, or traffic monitoring may be required as conditions of
approval.

Enforcement and Monitoring.
a.

The Town shall require a post-construction physical impact audit to verify compliance with
approved mitigation measures.

b.

Violations of approved physical performance standards may result in fines, operating restrictions,
or permit revocation.

Data Center Environmental Impact Analysis

Page 18 of 21

Page 72 of 75

Purpose
To evaluate and mitigate the potential environmental impacts of data center development—particularly land
disturbance, air and water quality degradation, and energy and carbon intensity, in a manner that protects
the Shenandoah Valley’s natural resources and supports sustainable land use in the Town of Front Royal.
Required Environmental Impact Analysis (EIA)
Applicants shall submit an Environmental Impact Analysis (EIA) prepared by a qualified environmental
consultant, certified engineer, or licensed planner. The EIA must be submitted as part of the rezoning
application package:

3.

4.

Total area of grading, clearing, and impervious surface coverage.

b.

Soil erosion potential and slope stability (per NRCS classification).

c.

Mitigation measures: erosion & sediment control plan, phased clearing, vegetated buffers.

T

a.

AF

Stormwater, Wastewater and Water Quality Analysis.
a.

Stormwater runoff projections under pre- and post-development conditions.

b.

Identification of potential pollutants of concern (e.g., heated discharge, oils, sediment).

c.

Description of Best Management Practices (BMPs) and green infrastructure used (e.g., bioswales,
retention basins).

d.

Compliance with VA DEQ stormwater regulations and Town stormwater ordinance.

e.

Impacts on nearby surface waters or floodplains (e.g., Shenandoah River tributaries).

f.

Plans for treatment of waste water from industrial processes. Waste water must be treated to
applicable EPA standards either on site or removed for treatment elsewhere before release.

R

2.

Land Disturbance and Soil Impact Assessment.

D

1.

Air Quality and Emissions Impact.
a.

Estimation of greenhouse gas emissions, diesel generator emissions (NOx, PM2.5, CO2).

b.

Identification of airborne pollutants during construction and backup power use.

c.

Mitigation plans: generator testing limits, air filtration, clean diesel or battery backup.

Energy and Carbon Intensity Analysis.
a.

Projected annual energy consumption and Peak Load in Mega Watts (MW).

b.

Use of renewable energy sources, energy efficiency measures Power Use Effectiveness (PUE)
targets, server cooling efficiency).

c.

Carbon offset strategies, if applicable.

Page 19 of 21

Page 73 of 75

d.

7.

a.

Description of site’s pre-development vegetation, habitat, and biodiversity.

b.

Inventory of wetlands, streams, or critical habitats based on field survey or state/federal
datasets.

c.

Documentation of compliance with the Chesapeake Bay Preservation Act, if applicable.

d.

Wildlife impact mitigation (e.g., tree preservation, fencing, lighting restrictions for nocturnal
species).

Hazardous Materials and Spill Prevention Plan.
Identification of onsite fuel or chemical storage (e.g., diesel, refrigerants, batteries).

b.

Spill containment and response strategies.

c.

Emergency environmental response procedures and coordination with Fire & EMS.

Facility Life Cycle Plan.

T

a.

AF

6.

Ecological and Habitat Impact Assessment.

a.

A facility life cycle plan shall be included prior to approval of site plan.

b.

Comprehensive planning to provide information needed to make sound decisions about facility
project planning and base development.

c.

Design.

R

5.

Leadership in Energy and Environmental Design (LEED) or equivalent sustainability certification
plan (if proposed).

d.

D

i. The materials, technologies, and types of systems chosen that have a direct and life-long
impact on operation, maintenance, repair, and dispose of the facility.
Restoration and Disposal.
i. Plans for repurposing, demolition and rehabilitation of land after end of use of facility.
8.

Review Standards.
The Zoning Administrator, Town Council (Town Engineer), and Planning Commission shall evaluate the
EIA to determine:

9.

a.

Whether proposed mitigation sufficiently reduces impacts to soil, air, water, and habitat.

b.

If the project complies with Town ordinances, State DEQ standards, and federal Clean Water/Air
Acts.

c.

The project’s alignment with sustainable development goals of the Town Comprehensive Plan.

Conditions of Approval.

Page 20 of 21

Page 74 of 75

Approval of any zoning, site plan, or zoning permit for a data center is contingent upon:
a.

Town verification of compliance with applicable stormwater, erosion, and pollution
control measures.

b.

Developer commitment to implement all environmental mitigations identified in the approved
EIA.

c.

Provision of updated documentation if project changes increase environmental footprint.

10. Post-Construction Monitoring.
For major facilities, the Town may require annual post-construction reporting, submitted to Planning
and Zoning on:
Actual energy use and carbon emissions vs. projected.

b.

Groundwater or surface water sampling.

c.

Long-term maintenance of stormwater Best Management Practices (BMPs) and erosion controls.

D

R

AF

T

a.

Page 21 of 21

Page 75 of 75

CLOSED MEETING
AGENDA STATEMENT

Meeting Date: May 11, 2026

Item# 6

MOTION ON TO GO INTO CLOSED MEETING
To be approved by affirmative recorded vote, with motion set forth in detail in the minutes. Council may TAKE ACTION in open session following closed meeting.

I move that Town Council convene a closed meeting, pursuant to Sections 2.2-3711 and 2.2-3712 of the Code of
Virginia, for the following purpose:
1) pursuant to Section 2.2-3711(A)(8) of the Code of Virginia, for consultation with legal counsel employed or
retained by a public body regarding specific legal matters requiring the provision of legal advice by such counsel,
more specifically, the 522 Corridor PILOT Agreement.

Motion to Certify Closed Meeting at its Conclusion

[At the conclusion of the Closed Meeting, immediately re-convene in open meeting and take a roll call vote on the following:]

I move that Council certify that to the best of each member's knowledge, as recognized by each Council member’s
affirmative vote, that only such public business matters lawfully exempted from Open Meeting requirements under
the Virginia Freedom of Information Act as were identified in the motion by which the Closed Meeting was convened
were heard, discussed or considered in the Closed Meeting by Council, and that the vote of each individual member
of Council be taken by roll call and recorded and included in the minutes of the meeting of Town Council.

Moved ____________________ Seconded ____________________
Rappaport _________ DeDomenico-Payne __________ Ingram __________ Wood __________ Sealock __________ Veitenthal __________

Outcome

Not yet recorded. The record stays open — outcomes are added as minutes and vote results are published.

Provenance

Where this record came from. Every source is listed, permanently.

  • Agenda Watch · Aug 4, 2026

Permanent ID DKT-2026-000380 — this record is never deleted.

Record history

Every change to this record, logged as it happened.

  • Aug 4, 2026 Filed on the Docket
  • Aug 4, 2026 Full document archived — public record
  • Sep 18, 2026 Record updated

← The full Docket · every meeting, vote, and action on the permanent record · also in the National Record Index.