The Docket · Government Meeting · DKT-2026-005333

On the agenda: Independence meeting — DATA CENTER (Nov 17)

Past  ⚠ Agenda Watch  Independence, Virginia · Tuesday, November 17, 2026 — 2 days ago

About this record

The published agenda for the November 17, 2026 meeting contains: "DATA CENTER", "Data Center", "server farm", "colocation". The meeting has passed. The agenda stays here as a permanent public record.

WhenTuesday, November 17, 2026
Check the agenda document for the meeting time.
WhereIndependence, Virginia
On the record“DATA CENTER”“Data Center”“server farm”“colocation”“Data center”“data center”

The agenda, word for word

Government public record — the full text of the published document, archived November 17, 2026. Gold highlighting of key terms is ours, not the original’s. Read the original document ↗

18 pages · scroll to read
Page 1 of 18

1. Planning Commission Regular Meeting
Documents:
AGENDA_2026_11-17.PDF
2.

6:00 P.M. Planning Commission Regular Meeting
Documents:
GRAYSON COUNTY_PRELIM DRAFT ORDINANCE_DATA
CENTERS_11.5.2026.PDF
GRAYSON COUNTY_PRELIM DRAFT POLICY_DATA CENTERS_11.5.2026
DRAFT MARKUP.PDF

Page 2 of 18

Grayson County Planning Commission Agenda
Grayson County Courthouse, Boardroom
Tuesday, November 17, 2026, 6:00 P.M.
6:00 p.m.

Call to Order: Brian Walls, Chairman

Opening Business

Approval of Agenda

Approval of October 20, 2026, meeting minutes

6:05 p.m.

Public Comment

6:15 p.m.

Old Business

Data Center Policy & Regulation Discussions

7:00 p.m.

New Business

7:30 p.m.

Staff Updates

7:45 p.m.

Adjourn

- MEETING DECORUM –
All official meetings conducted within these chambers are to be observed by the following
decorum:
 Behavior during all official meetings shall be consistent with the behavior exercised in any
court or legislative room found within the Commonwealth of Virginia; and,
 There shall be no outbursts, booing, heckling or other forms of disrespectful behavior by any
individuals present within these chambers; and,
 Persons wishing to speak shall do so respectfully and in accordance with the applicable Rules
of Procedures and/or at the specific direction of the presiding official; and,
 Out of respect for the official business being conducted, for those conducting the official
business and for those present for the same purpose, there shall be no private conversations
taking place in the audience or other forms of distractive behavior or nuisance; and,
 Please turn off cell phones and other such devices before entering these chambers.

Page 3 of 18

11/5/2026 DRAFT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

Preliminary Data Center Zoning Ordinance Amendments – For Discussion and
Feedback
Drafting note: bracketed values and section numbers are policy decisions or crossreferences to confirm. The proposed language is organized as amendments to Articles 2, 3,
and 4.
Article 2 - Definitions
Amend Article 2, Definitions, of the Zoning Ordinance to add the following definitions
alphabetically; renumber the sections as necessary:
Call Center: A facility principally occupied by personnel who provide telephone,
electronic messaging, customer support, sales, dispatch, or similar
communications services. A call center may contain ordinary information
technology and telecommunications equipment incidental to its personnel-based
operations but does not include a Data Center.
Data Center: A building, portion of a building, or group of buildings whose
principal use is the centralized housing, operation, or management of computer
servers, digital data storage, network equipment, or related information
technology infrastructure for processing, storing, transmitting, or distributing
digital data. The term includes server farms, colocation facilities, cloud computing
facilities, bitcoin mining, and substantially similar operations, whether operated
for one user or multiple users. A Data Center includes associated mechanical,
cooling, electrical, and backup power equipment. The term excludes a Call Center
and an Accessory Data Processing and Server Facility that satisfies the definition
below.
Data Center Campus: Two or more Data Center buildings or phases on
contiguous or functionally integrated parcels under common ownership, control,
or coordinated development, including shared power, cooling, access, or other
supporting infrastructure. A campus shall be reviewed as one development for
purposes of this section, including reasonably foreseeable phases.
Accessory Data Processing and Server Facility: Computer servers, data storage,
network equipment, and associated infrastructure located within a building or on
a lot and customarily incidental and subordinate to a lawful principal use other
than a Data Center, serving primarily the operations of that principal use. Such
facilities shall not constitute a separate principal commercial service, colocation,
or hosting operation. Classification shall consider dedicated floor area, electrical
demand, equipment and cooling capacity, staffing, customer relationships, and
whether the facility could operate independently of the principal use. A facility
Page 1 of 12

Page 4 of 18

11/5/2026 DRAFT
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84

does not qualify as accessory solely because it is located on the same lot as
another use.
Closed-Loop Cooling System: A cooling system designed to recirculate cooling
fluid within a substantially closed circuit, with limited make-up water and no
routine once-through discharge of cooling water. This definition does not exempt
any discharge or withdrawal from applicable permits.
Sensitive Receptor: An existing dwelling, school, place of worship, park,
recreation area, or other location identified in this section at which noise, lighting,
visual, or air-quality impacts warrant particular consideration.
Article 4 - Industrial District (IND)
Amend Section 4-10, Industrial (I) District (IND), of the Zoning Ordinance as follows:

Amend § 4-10.1, Uses Permitted, by:
o deleting existing use “Call Centers and Data Processing/Storage Facilities”
o inserting separate uses: “Call Centers”; and “Records Storage and
Warehousing (physical records and materials, excluding Data Centers).”
o Accessory Data Processing and Server Facilities are permitted as accessory
uses to otherwise lawful principal uses, subject to Article 3, § 3-[XX].

Amend § 4-10.2, Special Uses Permitted, by adding:
o “Data Centers and Data Center Campuses, subject to Article 3, § 3-[XX].”
o Data Centers shall not be permitted by right, regardless of building area,
electrical demand, or number of servers. No Data Center shall be
permitted in any other zoning district.

New Section 3-[XX] - Data Centers
Amend the Zoning Ordinance to add a new section, Section 3-[XX], Data Centers, within
Article 3, General Requirements for All Zone Districts, as follows:
Section 3-[XX] - Data Centers
3-[XX].1 Purpose and applicability
The purpose of this section is to permit consideration of Data Centers and
Data Center Campuses only in the Industrial District while protecting the
County’s rural character, scenic and natural resources, public health and
safety, nearby land uses, and public infrastructure. These standards apply
to new Data Centers, Data Center Campuses, and material expansions. An
applicant may not segment buildings, parcels, or phases to avoid review.
Page 2 of 12

Page 5 of 18

11/5/2026 DRAFT
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

All applicable provisions of this Ordinance and other laws remain in effect;
the more restrictive applicable standard governs.
3-[XX].2 Accessory facilities and classification
An Accessory Data Processing and Server Facility shall not require a
Special Use Permit solely because it contains servers or network
equipment. The Zoning Administrator shall determine whether it remains
subordinate and incidental to the principal use. The owner shall provide
information reasonably necessary to make that determination. Where the
facility is principally used for third-party hosting, colocation, or
independent digital data processing, or otherwise functions as a principal
Data Center, it shall be classified and reviewed as a Data Center. This
subsection does not excuse compliance with building, electrical, fire,
mechanical, or other applicable codes.
3-[XX].3 Special Use Permit required
A Special Use Permit (SUP) under § 5-11 shall be required before
establishment, construction, conversion, or material expansion of a Data
Center or Data Center Campus. The application shall identify the full
anticipated campus buildout, including phases, associated infrastructure,
and cumulative impacts. Material changes to approved site layout,
capacity, generation, cooling, or operating characteristics shall require
review by the Zoning Administrator to determine whether an SUP
amendment is necessary. No permit under this section authorizes a use
prohibited by federal or state law.
3-[XX].3.1 Preapplication conference and completeness
Before filing, the applicant shall meet with County staff to identify
site-specific issues and applicable agency approvals. Technical
studies required under this section shall be prepared by
appropriately qualified professionals retained by the applicant. The
Zoning Administrator may require additional information or
clarification as necessary to evaluate compliance with applicable
standards, consistent with state law. The County may obtain
independent peer review at the applicant’s expense to the extent
authorized by law and established fee procedures.
3-[XX].3.2 Application materials
An application for a Special Use Permit for a Data Center or Data
Center Campus shall include the following information, studies, and
plans, as applicable, sufficient to evaluate the proposed facility's
consistency with the Comprehensive Plan and compliance with this
Ordinance and other applicable laws and regulations. Information
Page 3 of 12

Page 6 of 18

11/5/2026 DRAFT
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169

shall address the proposed facility at full anticipated buildout,
including all proposed phases, buildings, infrastructure, and
accessory facilities.
3-[XX].3.2.1 General Site and Development Information.
a. A project narrative describing the proposed
development, demonstrating compliance with applicable
requirements of this Ordinance, and explaining how the
proposal is consistent with the County’s Comprehensive
Plan, including its Data Center Policy.
b. A boundary survey, existing conditions plan, and master
site plan identifying all proposed phases of development.
c. Proposed building footprints, elevations, maximum
building heights, grading, landscaping, buffers, screening,
and visual simulations from identified public viewpoints.
d. A context map extending at least [one mile] from the
property boundary identifying surrounding land uses;
residential dwellings; schools; places of worship; parks
and recreation areas; registered historic sites; agricultural
and forestland; streams and other surface waters,
including the New River; and other environmentally
sensitive or protected resources.
e. A transportation and construction traffic management
plan identifying anticipated traffic volumes, proposed
access, construction routes, and provisions for emergency
vehicle access.
3-[XX].3.2.2 Electrical Demand and Infrastructure.
a. A statement identifying the facility's reasonably
anticipated electrical power demand, expressed in
megawatts (MW), at initial operation and full anticipated
buildout, including the demand associated with each
proposed phase. The statement shall identify whether the
proposed facility meets the definition of a High Energy
Use Facility (HEUF) under Virginia Code § 15.2-2209.5.

Page 4 of 12

Page 7 of 18

11/5/2026 DRAFT
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212

b. An electrical infrastructure plan identifying, to the extent
known and practicable, proposed utility interconnections,
on-site substations, transmission infrastructure,
distribution facilities, and backup or supplemental
generation equipment.
c. For a proposed HEUF, documentation of the submission
required from the electric utility providing retail service to
the facility pursuant to Virginia Code § 15.2-2209.5(C).
Such submission shall describe, to the extent known and
practicable, any new or existing substations that will serve
the facility and the anticipated transmission voltage
required.
3-[XX].3.2.3 Water Supply, Cooling, and Wastewater.
a. A water supply and cooling system assessment
identifying proposed cooling technologies, water sources,
estimated average and peak water demand, annual water
withdrawals, and proposed water conservation measures.
b. A wastewater management assessment identifying
anticipated wastewater quantity and characteristics,
proposed discharge or disposal methods, and any
necessary pretreatment arrangements.
c. Documentation demonstrating consistency with the
cooling system and wastewater requirements of this
Ordinance.
3-[XX].3.2.4 Noise Assessment and Mitigation.
a. A preconstruction noise assessment prepared by a
qualified acoustical professional identifying existing
ambient sound conditions and projecting noise
generated by the proposed facility at full anticipated
buildout, including all mechanical equipment, cooling
systems, electrical equipment, backup generators, and
other significant noise sources.
b. The assessment shall evaluate sound levels using both Aweighted (dBA) and C-weighted (dBC) measurements, as
appropriate, and shall address low-frequency sound,
Page 5 of 12

Page 8 of 18

11/5/2026 DRAFT
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255

tonal characteristics, cumulative equipment noise, and
anticipated variations associated with different operating
conditions.
c. The assessment shall identify and evaluate potential
impacts at property boundaries and nearby sensitive
receptors, including residential dwellings, schools, and
other locations subject to applicable noise standards.
d. A Noise Mitigation Plan identifying proposed measures
to comply with applicable noise standards, including
equipment placement, acoustic enclosures, barriers,
setbacks, operating procedures, and postconstruction
verification and monitoring.
e. For a proposed HEUF, the assessment shall specifically
examine the sound profile of the facility on residential
units and schools located within 500 feet of the HEUF
property boundary, in accordance with Virginia Code §
15.2-2209.5(B).
3-[XX].3.2.5 Lighting and Visual Impacts.
a. A lighting and photometric plan identifying proposed
exterior lighting, fixture types, illumination levels,
shielding, and measures to minimize light trespass and
glare.
b. An assessment of potential visual impacts from public
roads, parks, recreation areas, and other identified public
viewpoints, including proposed mitigation measures.
3-[XX].3.2.6 Air Emissions and Backup Power.
a. An inventory of all proposed stationary combustion
sources, including backup or supplemental generators,
identifying the number, type, fuel source, anticipated
operating conditions, and applicable air permitting
requirements.
b. An assessment of anticipated air emissions associated
with equipment testing, emergency operation, and any
proposed nonemergency operation.
Page 6 of 12

Page 9 of 18

11/5/2026 DRAFT
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296

c. Proposed measures to minimize emissions, exhaust
impacts, and potential conflicts with adjacent land uses.
3-[XX].3.2.7 Stormwater, Environmental Resources, and
Natural Hazards.
a. Preliminary stormwater management, erosion and
sediment control, drainage, and floodplain information.
b. Identification of streams, wetlands, floodplains, steep
slopes, and other sensitive natural resources potentially
affected by the development.
c. For a proposed HEUF, a site assessment examining, to the
extent practicable, potential effects on:
i.
ii.
iii.
iv.
v.

Groundwater and surface water resources;
Agricultural resources;
Parks;
Registered historic sites; and
Forestland located on the HEUF site or
immediately contiguous land.

3-[XX].3.2.8 Fire Protection and Emergency Response.
a. A fire protection, hazardous materials, and emergency
response plan addressing fire suppression, emergency
access, hazardous materials storage and handling, spill
prevention and response, coordination with emergency
service providers, and other site-specific emergency
considerations.
3-[XX].3.2.9 Construction, Operations, Monitoring, and
Decommissioning.
a. A construction management plan addressing phasing,
anticipated construction activities, construction traffic,
hours of operation, and measures to minimize impacts on
surrounding properties.

Page 7 of 12

Page 10 of 18

11/5/2026 DRAFT
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338

b. An operations and compliance monitoring plan
identifying procedures for monitoring applicable noise,
lighting, water, and other operational requirements.
c. A complaint-response procedure identifying responsible
contacts, investigation procedures, corrective actions, and
reporting to the County.
d. A preliminary decommissioning and site restoration plan
addressing the discontinuation of operations, removal or
disposition of equipment and improvements, and site
stabilization.
3-[XX].3.2.10 State-Mandated Site Assessment
Requirements for High Energy Use Facilities.
a. In addition to the requirements above, an application for
a new HEUF, as defined in Virginia Code § 15.2-2209.5,
shall include the site assessment required by that section.
The assessment may be incorporated into the studies and
plans otherwise required by this subsection, provided
that all applicable statutory requirements are addressed.
b. The applicant shall identify the location of all residential
units and schools within 500 feet of the HEUF property
boundary and evaluate the facility's projected sound
profile at such locations, to the extent practicable.
c. The applicant shall provide the site assessment
information concerning environmental and land resource
impacts identified in § 3-[XX].3.2.7(c).
d. The applicant shall coordinate with the electric utility
providing retail service to the proposed HEUF regarding
the submission required by Virginia Code § 15.22209.5(C).
e. The information required by this subsection shall be
provided within the applicable statutory review period
and, to the extent practicable, prior to action on the
application. No application for a new HEUF shall be
approved without satisfaction of the requirements of
Page 8 of 12

Page 11 of 18

11/5/2026 DRAFT
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381

Virginia Code § 15.2-2209.5, subject to its provisions
concerning practicability and timing.
f. The applicability of the state-mandated assessment
requirements to expansions or modifications of existing
or previously approved facilities shall be determined in
accordance with Virginia Code § 15.2-2209.5(F). Nothing
in this subsection shall exempt such development from
otherwise applicable requirements of this Ordinance.
3-[XX].3.3 Review and Use of Submitted Information.
The County shall consider the information and assessments
required by this section in determining the proposed facility's
consistency with the Comprehensive Plan and compliance with
applicable zoning standards and other laws and regulations. The
County may request reasonable clarification or supplemental
information necessary to evaluate the proposed use, consistent with
applicable law and review deadlines. Nothing in this section shall be
interpreted to transfer, modify, or supersede the jurisdiction or
regulatory authority of the Virginia State Corporation Commission
or any other state or federal agency.
3-[XX].3.4 Findings for approval
In addition to § 5-11, in their consideration of Special Use Permit
applications for Data Centers or Data Center Campuses, the
Planning Commission and Board shall consider: consistency with
the Comprehensive Plan and Data Center Policy; compatibility with
surrounding uses and rural/scenic character; noise, lighting, air,
water, and environmental impacts; proximity to the New River,
tributaries, parks, schools, and places of worship; adequacy of
roads, utilities, and emergency services; cumulative impacts and
phased buildout; and the effectiveness and enforceability of
proposed mitigation. Approval may include lawful, reasonable
conditions addressing demonstrated site-specific impacts.
3-[XX].4 Standards
Data Centers and Data Center Campuses shall be subject to the following
standards:
3-[XX].4.1 Location, separation, and site design
Data Centers shall be located only on IND-zoned land. Buildings,
cooling equipment, generators, substations, and other potentially
impactful components shall be located to minimize effects on
Page 9 of 12

Page 12 of 18

11/5/2026 DRAFT
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424

adjoining properties and sensitive receptors. Minimum setbacks
shall be [___ feet] from residential property lines; [___ feet] from
schools and places of worship; [___ feet] from public parks and
recreation areas; [___ feet] from perennial streams and tributaries;
and [___ feet] from the New River, measured from [ordinary highwater mark / delineated bank]. The Board may require greater
separation or site-specific conditions based on demonstrated
impacts. Required riparian buffers and floodplain restrictions shall
also apply.
3-[XX].4.2 Building scale, visual impacts, and screening
Maximum building height shall be [___ feet], subject to applicable
Industrial District standards unless expressly amended. The
applicant shall demonstrate compatibility with public viewsheds and
adjacent land uses through building placement, massing, colors,
earthwork, preserved vegetation, and screening. Outdoor
equipment and service yards shall be screened from public rightsof-way and sensitive receptors to the maximum practicable extent.
Landscaping shall use species suited to local conditions; preserved
mature vegetation is preferred. Fencing and security design shall
not create unnecessary visual or lighting impacts.
3-[XX].4.3 Noise standards and verification
Before approval of a Special Use Permit, the applicant shall submit a
baseline noise survey and predictive acoustic model for normal
operation, cooling equipment, transformers, and backup generators
during testing and reasonably foreseeable operating conditions.
Evaluate A-weighted and C-weighted sound levels (dBA and dBC),
tonal and low-frequency noise, daytime and nighttime periods, and
cumulative campus impacts. Compliance points shall include the
facility boundary, adjoining property lines, and the exterior of
existing dwellings and other sensitive occupied structures, including
accessory residential structures where applicable. Maximum
allowable levels shall be established as follows: [daytime dBA ___;
nighttime dBA ___; dBC ___; measurement period ___; locationspecific criteria ___]. The applicant shall implement the approved
mitigation plan and demonstrate compliance through
postconstruction testing within [90] days of initial operation and
after material changes. Testing shall use a documented,
reproducible method and qualified acoustical professionals.
Exceedances shall require prompt corrective action and retesting.
The SUP may establish additional monitoring, complaint
investigation, and reporting requirements. Emergency operations
Page 10 of 12

Page 13 of 18

11/5/2026 DRAFT
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468

and routine generator testing shall be separately addressed,
without creating an unlimited exemption.
3-[XX].4.4 Lighting
Provide full-cutoff, shielded, downward-directed exterior lighting,
limited to the minimum necessary for safe operation and security.
No direct light spill shall occur onto adjoining residential properties
above [___ footcandles] at the property line. Submit photometric
plans showing fixtures, mounting heights, controls, and spillover.
Use motion activation and dimming where compatible with safety
and security. Prohibit unnecessary architectural uplighting and
skyward illumination.
3-[XX].4.5 Water, cooling, and wastewater
Only air-cooled or closed-loop cooling systems shall be permitted.
Once-through cooling systems are prohibited. The applicant shall
disclose projected peak and average water demand, sources,
conservation measures, drought contingencies, and wastewater
characteristics. Any industrial or process wastewater shall receive
pretreatment where required by the receiving utility or applicable
law. No discharge, withdrawal, or connection is authorized without
applicable approvals. The SUP may require periodic reporting of
actual water use and material deviations from approved estimates.
3-[XX].4.6 Backup power, emissions, and energy facilities
Applications for Special Use Permit shall identify the number, type,
fuel, capacity, exhaust locations and stack heights, anticipated
annual testing hours, and proposed operating protocols for
generators and other combustion equipment. Exhaust shall be
oriented and located to minimize impacts on occupied buildings
and public areas, consistent with safety codes and applicable air
permits. Routine testing shall occur during [specified daytime
hours] except where prohibited by controlling law or necessary for
safety. Backup equipment shall not be used for regular commercial
power generation or routine peak shaving unless separately
authorized through an SUP amendment and all required permits.
On-site nuclear reactors or nuclear power generation facilities are
prohibited as accessory components of a Data Center under this
section.
3-[XX].4.7 Emergency preparedness and public infrastructure
Submit fire protection, battery and fuel storage, hazardous
materials, spill prevention, access, and emergency response plans
Page 11 of 12

Page 14 of 18

11/5/2026 DRAFT
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502

for review by applicable agencies. Demonstrate adequate road
access, fire apparatus circulation, and water supply for fire
protection. Identify major utility improvements and constructionrelated impacts. The SUP may require appropriate mitigation of
site-related impacts where supported by applicable authority and
project evidence.
3-[XX].5 Operations and decommissioning requirements
Data Centers and Data Center Campuses shall be subject to the following
operations and decommissioning requirements:
3-[XX].5.1 Operating compliance, monitoring, and complaints
The owner/operator shall maintain an on-site or continuously
available responsible contact and an accessible complaint process.
Keep records of noise testing, generator testing and nonemergency operation, water use, reportable incidents, and
corrective measures. Submit an annual compliance certification to
the Zoning Administrator by [July 1], including required technical
monitoring results and a summary of complaints and resolutions.
The County may require additional testing upon a documented
complaint or evidence of noncompliance, subject to lawful
procedures. Failure to comply may be enforced under the
Ordinance and SUP conditions.
3-[XX].5.2 Discontinuance and decommissioning
Provide a decommissioning plan identifying procedures for removal
of equipment, fuels, batteries, and hazardous materials; site
stabilization; and disposition of unused structures. Upon permanent
cessation of operations for [12] consecutive months, the owner shall
implement the approved plan unless the County approves an
extension.

Page 12 of 12

Page 15 of 18

11/5/2026 DRAFT

Preliminary Draft Policy – For Discussion and Feedback
Data Center Policies
Data Centers
Data centers, the facilities housing the computing and networking infrastructure
supporting cloud computing, artificial intelligence, and digital services, have become
one of the most significant land use and economic development issues facing localities
across Virginia. Virginia hosts the largest concentration of data center capacity in the
world, and data centers now account for roughly one-quarter of the Commonwealth's
electricity consumption, a share projected to approach nearly half by 2030. As land,
power, and interconnection opportunities in Northern Virginia become increasingly
constrained, developers are looking further south and west for sites with available land
and transmission access, bringing data center interest to rural localities that have not
historically experienced this type of development pressure.
Unlike utility-scale solar and wind facilities, which generate power, data centers are
significant, continuous consumers of electricity and, depending upon the cooling
technology employed, may also have significant water demands. Their development
raises a distinct set of land use considerations, including the potential to strain local
utility and transportation infrastructure, and noise, light, and aesthetic impacts on
surrounding rural and residential areas from cooling equipment, backup generation,
continuous operation, and large-scale industrial building forms. At the same time, data
centers can provide substantial capital investment and local tax revenues, diversify the
County’s tax base, and create construction and permanent employment opportunities.
Properly planning for and enforcing appropriate development standards can lead to
success in Grayson County while preserving the County’s rural character.
General Land Use Strategies for Data Centers
With regard to data center development, the County establishes the following general
land use strategies:

Support the amendment of the Zoning Ordinance to establish “Data Center” as a
distinct, defined use, separate and apart from the existing “Call Centers and Data
Processing/Storage Facilities” use category, allowed only within the Industrial
(IND) District subject to approval of a Special Use Permit (regardless of facility
size or capacity), with corresponding standards and regulations consistent with
the policy statements in this addendum. The Zoning Ordinance should establish
clear definitions and objective criteria distinguishing “Data Center” uses from
accessory server facilities, call centers, and other data processing or storage uses
that may be permitted by-right.
Accommodate smaller-scale data processing and server facilities that are
accessory and incidental to an otherwise permitted principal use (for example,

Page 16 of 18

11/5/2026 DRAFT

medical offices, financial institutions, and schools) as an allowed accessory use, so
that this activity is not inadvertently captured by data center-specific standards
intended for stand-alone facilities.
Generally direct data center development to land currently zoned Industrial.
Proposals to expand the Industrial District or rezone additional property for data
center development should be carefully evaluated based upon compatibility with
the Comprehensive Plan, availability of adequate infrastructure, impacts on
surrounding properties and resources, and the ability of the proposed location to
satisfy the policies and development standards established by the County.
Support data center development that demonstrates clear economic
development benefits to the County, including capital investment, tax revenue,
and employment.
Require that data center development not strain existing water, sewer,
transportation, and electric utility infrastructure, that it utilize closed-loop or aircooled cooling systems and provide any necessary wastewater pretreatment, and
that data centers be designed and operated to mitigate noise, light, aesthetic,
and environmental impacts on the surrounding area and County.
Require applicants to demonstrate that adequate electrical capacity can be
provided and to identify anticipated energy demand, the proposed means of
electrical service, necessary transmission, distribution, substation, or other
infrastructure improvements, backup and on-site generation systems, and
measures proposed to reduce or manage demand on the electric grid. Nuclear
power generation shall not be permitted as an accessory or supporting use
associated with data center development.

Future Land Use Considerations
The County will consider data center facilities, through the review of a Special Use
Permit, in the Industrial (IND) zoning district only. In addition to the regulations and
standards for data center facilities to be established within the Zoning Ordinance, and
requirements and standards applicable to the consideration of all Special Use Permits,
Special Use Permit applications for data center facilities must be evaluated based upon
the following criteria. The County may require independent technical review of
submitted studies, at the applicant’s expense where authorized by law. Conditions may
be imposed upon individual Special Use Permits to ensure consistency with these
criteria and to mitigate potential or anticipated negative impacts associated with the
design or location of a facility; individual applications may be denied where one or more
of these criteria cannot be met, outright or through the imposition of conditions.
1. Applications shall demonstrate the anticipated economic development benefits
of the proposed facility to the County, including projected capital investment, tax
revenue, and employment, through a thorough economic analysis.

Page 17 of 18

11/5/2026 DRAFT

2. Applicants shall demonstrate, in coordination with the applicable utility providers
and the County, that adequate water, sewer, transportation, and electric capacity
exists, or will be provided at the applicant's expense, to serve the proposed
facility without placing an undue burden on existing infrastructure or other users.
3. Applications should identify any new or expanded electrical transmission or
distribution facilities, substations, water or wastewater improvements,
transportation improvements, or other off-site infrastructure anticipated to serve
the project and evaluate associated land use and community impacts.
4. Facilities, including generators, cooling equipment, and other mechanical
systems, shall be sited, designed, and screened, through building orientation,
height and size limits, setbacks, landscaped buffers, and equipment enclosures, to
minimize noise, emissions, and visual impacts on adjacent properties, and utilize
full cut-off exterior lighting fixtures to minimize light trespass and glare.
5. Operational noise, including noise associated with cooling equipment,
mechanical systems, and routine testing of backup generation equipment, should
be minimized at adjoining properties and sensitive uses through site layout,
equipment location and orientation, setbacks, screening, enclosures, and other
appropriate mitigation measures. Applicants shall provide a professional noise
analysis that includes a pre-construction study of existing ambient sound levels,
modeling of anticipated operational noise, and proposed mitigation, measured in
both dBA and dBC sound levels. A post-construction noise study, also measured
in dBA and dBC, shall be required to verify that operational noise is consistent
with the approved analysis and established limits, with periodic monitoring
thereafter. For facilities subject to Va. Code § 15.2-2209.5, the analysis shall also
include the sound profile required by that section for residences and schools
within 500 feet of the property boundary. The Zoning Ordinance should establish
measurable noise limits, measurement locations, and reporting and complaintresponse procedures, consistent with any applicable state noise regulations.
6. Facilities should be sited and designed to avoid or minimize adverse impacts on
residences; schools, churches, and parks; historic, cultural, recreational, and
environmentally sensitive resources; important viewsheds such as those along the
New River and its tributaries; and the County’s rural character. Existing
vegetation, natural landforms, setbacks, buffers, and other site-design measures
should be utilized to minimize visual and land-use impacts. The Zoning
Ordinance should establish appropriate setbacks and separation distances from
these uses and resources, and applications should include a viewshed analysis.
Accessory Data Processing and Server Facilities
Smaller data processing and server facilities that support the day-to-day operations of
an otherwise permitted principal use, such as a doctor's office, bank, or school, are
common and are not the type of stand-alone, large-scale facility that this policy and the
corresponding Special Use Permit process are intended to address. The Zoning

Page 18 of 18

11/5/2026 DRAFT

Ordinance should continue to allow these accessory facilities in all districts in which the
associated principal use is permitted, subject to appropriate objective thresholds or
criteria.

Outcome

Not yet recorded. The record stays open — outcomes are added as minutes and vote results are published.

Provenance

Where this record came from. Every source is listed, permanently.

  • Agenda Watch · Nov 17, 2026

Permanent ID DKT-2026-005333 — this record is never deleted.

Record history

Every change to this record, logged as it happened.

  • Nov 17, 2026 Filed on the Docket
  • Nov 17, 2026 Full document archived — public record
  • Nov 18, 2026 Record updated

← The full Docket · every meeting, vote, and action on the permanent record · also in the National Record Index.